Power cable high voltage steel tape/wire/al wire armoured underground power cable
Supplier: Marble, granite, stones, slates, tiles, power cord, wires, cables , cable assemblies, tyre scrap, used tyres, steel tire wire scrap, firewoods, pistachios, hazelnuts, textiles
Buyer: Pellets, briquettes, firewood, textiles
18/30 (36) KV, 6/10 (12) KV ,185SQ.MM 3 CORE COPPER CONDUCTOR XLPE INSULATED ALUMINIUM WIRE ARMOURED underground cable
1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable. 2. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable. Specific property for usage of 110KV~220KV XLPE high-voltage cable 1. Cable's conductor highest working temperature is allowed up to 90º C, and overload when meet an emergency is 130º C, When short circuit (in � 5 seconds) the highest temperature is 250º C 2. When installing or laying cable, the ambient temperature should be less than -20º C, and have to give a preheat to cable. 3. The minimum bending diameter(in follow the table): Note: In form, D0 is a real test value to cable's outer diameter. 4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=K� Core NO. � Section (kg), in formula, the coefficient K value should be: The copper core get 7, the aluminum core get 4. 5. Allowed biggest lateral-press P, when cable is being bent The single core cable is required P� 500kg/m. P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened. http://www.alibaba.com/product-detail/240mm-300mm-400mm-500mm-630mm-800mm_60455062615.html?spm=a271v.8028081.0.0.ziQH7w
SFEX CT Manteau, also called the Cable Tray Manteau, is very efficient in extinguishing the initial fire suppression with immediate responses in case of fire because when a micro capsule for fire extinguishing reacts to a certain temperature and flame, it automatically disperses extinguishing agents. It\'s based on a cooling fire extinguishing method, shows an excellent characteristic of being able to extinguish a fire completely with an immediate response at the time of initial fire if you cover it over the electric power line. SFEX Solution : SFEX CT Manteau / SFEX AP Tape 1. Horizontal Section Fire : Access Floor, Cable Pit, and Cable Tray Installation and How It Works 1. Cover the SFEX CT Manteau. 2. Prevent the spread of fire with extinguishing/flame retardance properties 2. Vertical Section Fire Installation and How It Works 1. Wind the SFEX AP Tape on the cable. 2. Prevent the spread of fire with extinguishing/flame spread prevention properties Test Result : AP Tape Test Item Test Standard Unit Test Result Flame test of vertically placed cables The carbonization length should not exceed 2.5mm from the bottom edge of the burner - Do not exceed (carbonization length: 0.6m) During installation, photograph after installation *Test Information Test Facility Standard : KS C IEC 60332-3-10 : 2003(Compliant) Volume of nonmetallic material(L) per meter of test specimen : 1.5 (volume of nonmetallic material for finished cable, not including AP Tape) Number of test pieces : 5 Number of tiers : 1 Number of burners : 1 Position of test piece : Spatial type Flame application time (minutes) : 20 AP Tape installation method : AP Tape in 0.6/1 kV TFR-CV 4C 35 from the height of burner to the top 10cm gap between AP Tape and 20cm length of AP Tape
Supplier: 1 lv and mv power cables , telecommunication cables , lsfh , solar ,instrument and special cables. 2 copper rod 8 mm and copper wire from 1.60 to 3 3 pvc compounds