1.Application The NFC33-209 Standard AAAC Conductor Aerial Cable is used for 600V or lower overhead service applications such as power transimission and distribution for street lighting,outdoor lighting,and temporary service for construction. The operating temperatures should not to exceed 75°C for polyethylene(PE) insulated conductors or 90°C for crosslinked polyethylene(XLPE)insulated conductors. 2.Standard : NFC33-209,BS7870,GB/T12527-2008 3.Rated voltage : 1kV,10kV or 11kV 4.Specification Concentric strand Aluminum/ AlloyAAAC wires insulated by PE or XLPE as phase conductor, bare or insulated AAC/AAAC/ACSR/AACSR messenger
1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable. 2. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable. Specific property for usage of 110KV~220KV XLPE high-voltage cable 1. Cable's conductor highest working temperature is allowed up to 90º C, and overload when meet an emergency is 130º C, When short circuit (in � 5 seconds) the highest temperature is 250º C 2. When installing or laying cable, the ambient temperature should be less than -20º C, and have to give a preheat to cable. 3. The minimum bending diameter(in follow the table): Note: In form, D0 is a real test value to cable's outer diameter. 4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=K� Core NO. � Section (kg), in formula, the coefficient K value should be: The copper core get 7, the aluminum core get 4. 5. Allowed biggest lateral-press P, when cable is being bent The single core cable is required P� 500kg/m. P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened. http://www.alibaba.com/product-detail/240mm-300mm-400mm-500mm-630mm-800mm_60455062615.html?spm=a271v.8028081.0.0.ziQH7w
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
PVC Sheathed armoured power cable The product not only has good electric capability, but also has good chemical stabilization, simple structure, easy to use, and the laying of cable do not be limited by the fall. It is widely used at the transformer circuit which rated voltage is 6000V or under. The product is produced against IEC60502 and IEC60331, and the product can be produced against the standard of BS, DIN, and the standard required by the clients. 1. The long-term permissible operation temperature of the conductor shall not be higher than 70. 2. The max temperature of the conductor of cable should less then 160 when short circuit. (less then 5 second). 3. The cable is not limited by drop in level when being laid, and the environment temperature shall not be lower than 0. 4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardance. 5. Light weight, perfect bending properties, installed and maintained easily and conveniently. 6. Rated voltage: 0.6/1kV, 3.6/6kV. 7. Number of cores: One, two, three, four, five. Drum
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.