ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium. ACSR conductor is available in a range of steel strengths varying from 6% up to 40%. The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. Against any given resistance of conductor, ACSR conductor may be manufactured to have different tensile strengths as per requirement. The principal advantage of these conductors are their high tensile strength and light weight, covering longer spans with less supports. Due to the greater diameter of an ACSR conductor much higher corona limit can be obtained, giving a big advantage on high and extra high voltage overhead lines. Standards: ASTM - B 399 Metric Units ASTM - B 231 TS IEC 1089 DIN 48201 BS 215 UNE 21.018 Key Benefits: The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines. ACSR conductors consist of a solid or stranded steel core surrounded by strands of aluminum (E. C. GRADE). ACSR conductors are available in a wide range of steel, containing carbon from 0.5% to 0.85 %. The higher strength ACSR conductors are used for river crossings, overhead ground wires, installations involving extra long spans etc. Against any given resistance of conductor, ACSR may be manufactured within a wide range of tensile strength as per the requirement. Key Benefits: The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.
uctors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines. ACSR conductors consist of a solid or stranded steel core surrounded by strands of aluminum (E. C. GRADE). ACSR conductors are available in a wide range of steel, containing carbon from 0.5% to 0.85 %. The higher strength ACSR conductors are used for river crossings, overhead ground wires, installations involving extra long spans etc. Against any given resistance of conductor, ACSR may be manufactured within a wide range of tensile strength as per the requirement. Key Benefits: The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.
http://www.vericable.com/cables/overheadcable/88.htm
STANDARD:ASTM B549, B230 B502, B549 CAPACITY:2000ton/month The AW core, which consists of a thick layer of aluminum (approx. 10 percent of the nominal wire radius) over steel, gives ACSR/AW conductors the advantage of the light weight and good conductivity of aluminum with the high tensile strength and ruggedness of steel. It has the following main features: 1.good mechanical properties 2.improved electrical characteristics 3.excellent corrosion resistance 4.better Sag properties Specification Applicable Standards: ASTM, AS, BS, CSA, DIN, IEC, NFC, SS etc Aluminium Conductors, Aluminium Clad Steel Reinforced (ACSR/AS or ACSR/AW) are concentrically stranded conductors with one or more layers of hard drawn 1350-H19 aluminium wires on Aluminium Clad steel wire core. The core can be single wire or stranded depending on the size. The aluminum-clad steel core may consist of a single strand or a concentric stranded conductor of 7, 19, 37 or more wires.
Aluminum Conductor Steel Reinforced. Aluminum Conductor Steel Reinforced is used as bare overhead transmission cable and as primary and secondary distribution cable. This wire is suitable for use in all practical spans on wood poles, transmission towers, and other structures. Applications range from long, extra high voltage (EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. ACSR offers optimal strength for line design. Variable steel core stranding for desired strength to be achieved without sacrificing ampacity.
z
1. Applications Conductor(aac, aaac and acsr) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist. 1).The permissible long-time operating temperature for aerial conductor is 70oc. (2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power. (3).When connecting conductors, the conductor beside the connecting tube cant be prominent.Otherwise, the force on the operating conductors will be unbalanced.After connectors are install, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion. (4).Under installaion, the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress. According to your requirement
Bare Conductor Aac/aaac/acsr