The 4001 non-addressable control and indicating equipment forms the central part of a fire detection and alarm
System.The 2-wire 4001 is compatible with numens non-addressable devices.
The 4001 comes standard with features that allows flexibility and expandability. Default configuration programming
Facilitates out-of-box installation and rapid commissioning.
2, 4, 8, or 16 detection zones
Up to 32 non-addressable devices per alarm zone circuit
Configurable non-latching alarm zones, alarm dependency (zone coincidence detection), and output delay timer
3 access levels
Single-person test mode
Day/night mode
Manual activation of audio/visual alarm devices
Supervised auxiliary dc 24 v output
2 independently programmable non-addressable a/v alarm output circuits
2 programmable fire alarm relay outputs
Fault relay output
3 voltage-free inputs for remote reset, evacuation start/stop, and day/night mode
Supports up to 7 repeater panels
Features External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply fault Mains on Zone fire Zone fault Internal indicators: Open circuit zone fault Short circuit zone fault Zone isolated Engineer test selected Outputs: Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit) Ancillary connections for expansion modules will allow the following: Repeater panels Multiple sounder outputs Connection to landlord panel
Intelligent fire Detection system as a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. This system is located in outdoor area such small and middle sized cultureal assets, natural monument and outdoor facilities.
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station. Types of Fire Alarm System: All Fire Alarm Systems essentially operate on the same principle. If a detector detects smoke or heat or someone operates a break glass unit (manual break point), then alarm sounders operate to warn others in the building that there may be a fire and to evacuate. It may also incorporate remote signaling equipment which would alert the fire brigade via a central station. Conventional Fire Alarm System In a Conventional Fire Alarm System, a number of call points and detectors are wired to the Fire Alarm Control Panel in Zones. A Zone is a circuit and typically one would wire a circuit per floor or fire compartment. The Fire Alarm Control Panel has a number of Zone Lamps. The reason for having Zones is to give a rough idea as to where a fire has occurred. This is important for the fire brigade and of course for the building management. The accuracy of knowing where a fire has started is controlled by the number of Zones a Control Panel has and the number of circuits that have been wired within the building. The Control Panel is wired to a minimum of two sounder circuits which could contain bells, electronic sounders or other audible devices. Each circuit has an end of line device which is used for monitoring purposes. Addressable Fire Alarm System The detection principle of an Addressable System (Fire Alarm System) is similar to a Conventional System except that the Control Panel can determine exactly which detector or call point has initiated the alarm. The detection circuit is wired as a loop and multi devices may be connected to each loop. The detectors are essentially Conventional Detectors, with an address built in. The address in each detector is set by dil switches and the Control Panel is programmed to display the information required when that particular detector is operated. Additional Field Devices are available which may be wired to the loop for detection only i.e. it is possible to detect a normally open contact closing such as sprinkler flow switch, or a normally closed contact opening. Fire Alarm System comes with single loop as well as multi loops. It depends on requirement. The items which are integrated with Fire Alarm Systems are given belowâ?¦. Brands are available : AGNI, MORLEY, NOTIFIER, Modern Technologies gives you top class branded Fire Alarm System with affordable price. We also provide installation & maintenance services.
Product categories of Sensor Type of Fire Alarm, we are specialized manufacturers Sensor Type Of Fire Alarm, Sensor Type Fire Alarm suppliers/factory, wholesale high-quality products of Fire Alarm Sensor Type R & D and manufacturing, we have the perfect after-sales service and technical support. Look forward to your cooperation Here you can find the related products in Sensor Type of Fire Alarm, we are professional manufacturer of Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. We focused on international export product development, production and sales. We have improved quality control processes of Sensor Type of Fire Alarm to ensure each export qualified product. If you want to know more about the products in Sensor Type of Fire Alarm, please click the product details to view parameters, models, pictures, prices and other information about Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. Whatever you are a group or individual, we will do our best to provide you with accurate and comprehensive message about Sensor Type of Fire Alarm
Specifications:- * Control key switch * Mains healthy indicator * Continuous alarm signal * Built-in battery * Polarity protection for battery * Push buttons for Evacuate, Reset and Alarm silence * Monitored alarm circuits for both open and short circuit * Individual sounder circuits for zones (optional) * Indicators for charger fault and battery fault * All controls are on front fascia * Knockouts on top and bottom sides for easy installation * Main supply - 240 V AC +/- 10%, 50/60 Hz * Battery supply - 24 V DC (Sealed Lead Acid) * Glass fuse protection - Main supply, Charging voltage, Sounder circuit, Reserve battery connection * Auxiliary relay contacts -30 V DC, 1 A, NO/NC
SureFIRE fire alarm control panel provides a cost effective platform for a fire alarm system that is Reliable, Flexible and User-friendly. The panel has been designed with both installer and end user's requirements of Fire & Security Industry in mind. For installer, SureFIRE offers an out of the box and on the wall solution. Microprocessor controlled, user friendly design -16 Zones of Input -Reliable wide operating Voltage SMPS suitable for Indian Power Conditions -Regulated 24V for reliable Smoke Detector Operation -Standby Battery backup with CC/CV Battery Charger -Battery Low Voltage Cut-off to extend battery life -Drives upto 16 Hooters -Independent Potential free relays for Fire and Fault -Ethernet Connectivity Export-worthy Carton Box
Fire alarm control MIRA fire alarm control panel provides a cost effective platform for a fire alarm system that is Reliable, Flexible and User-friendly. The panel has been designed with both installer and end user's requirements of Fire & Security Industry in mind. For installer, MIRA offers an out of the box and on the wall solution. Microprocessor controlled, user friendly design -Reliable wide operating Voltage SMPS suitable for Indian Power Conditions -Operates from Single 12V, 7AH SMF Battery to save cost -Regulated 24V for reliable Smoke Detector Operation -Standby Battery backup with CC/CV Battery Charger -Battery Low Voltage Cut-off to extend battery life -Drives upto 4 Hooters -Independent Potential free relays for Fire and Fault Export-worthy Carton Packing