15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
3. SPO2 can testing for 0.1% Weak;
4. RA-LL impedance Respiration;
5. Trend Coexist Display;
6. OxyCRG Dynamic View Display;
7. Bed to Bed view Display;
8. Networking capacity and nurse calling system;
9. Options of printing, IBP, VGA and EtCO2;
10. UP to 4 hours working capacity of built-in rechargeable battery;
11.15" high resolution color TFT LCD display;
12. Large volume of tabular and graphic trends information storage and easy to recall;
13. Anti-ESU, anti- defibrillator;
14. Capture dynamic waveforms.
Technical specification:
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MO
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MO
Measuring Impedance Range: 0.3~5.0O
Base line Impedance Range: 0 – 2.5 KO
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
An intelligent device system with ( REM) Return electrode monitoring systems which kept continuous monitoring of patient impedance level and deactivate the generator if the fault in the patient/ return electrode contact is detected minimize the chances of burning . Memory record feature , with Real time Monitoring and instance response system for tissue density it samples the current and voltage 450,000 times per second which enables it to respond tissue impedance change in less then 10 millisecond which insuring the machine achieves optimum energy output levels quicker and more accurately- ensuring that only the precise voltage needed is safely delivered to each tissue type . 1. two pencil can work simultaneously. ( Optional ) 2.Automatic start and stop . ( Optional ) 3, wireless foot switch operational ( Optional) 4.Copatibale with other equipment ( Argan Plasma Coagulation system, Optimum smoke evacuation system ) Application of uses : General surgery, Gastroenterology, Dermatology, vascular surgery ,Obstetrics & Genecology, Heart/ Thoracic surgery , ORL/ENT, , Minimal Invasive surgery, cerebral surgery Neurosurgery ,Orthopedic & Plastic Surgery, Trans Urethral Resection ( Tur) etc
Patient Monitor
Multi-parameter patient monitor Nt3a: 10.4'' lcd Nt3b: 12.1''lcd Nt3e: 8.4''lcd Nt3f:6.4'' Ecg Input: 5 wires ecg cable Lead section: lead =¦, ==, ==/ avr, avl, avf/ v Gain·+mm/mv·¼: 1/4·+1/2·+1·+2·+4 Frequency response: diagnosis 0.05 - 100hz Monitor model 0.5 - 40 hz Surgery 1.0 - 25 hz Sweep speed(mm/sec): 12.5, 25, 50 Heart rate range: 30-254 bpm Heart rate accuracy : f+ 1 % St segment deviation analysis: -0.8-+0.8mv St accuracy : f+0.02mv Non-invasive blood pressure Measurement type : adult, pediatric, neonatal Measurement range: systolicffffff 4.0 - 37.0 kpa Diastolic ff1.3 - 33.0 kpa Mean 2.6 - 35.0 kpa Accuracy : f+ 0.4 kpa or 5 % Resolution: 0.1 kpa Protection : over pressure Pules oximetry Spo2 measurement range: 0 - 100 % Resolution: 1 % Pulse measurement range:30- 254bpm Accuracy: f+ 2 % Resolution: 1 bpmTemperature Measurement range: 29 - 45 f¦ Accuracy: f+ 0.1 f¦ Resolution: 0.1 f¦ Response time: f_ 3 min.Respiration rate Measurement range: 0 - 120 bpm·+adult·¼ Accuracy: f+ 1 bpm or 5 % Resolution: 1 bpmCo2 Measurement range: 0 % - 10.0 % ·+ins co2 and et co2·¼ Accuracy: f+ 2 mm hg ·+·+ 5 %ffmeasurement value·¼ 10 % ·+·+ 5 %ffmeasurement value·¼ Response time: 180 msEnvironment -fffffffffffffffffffffopreation ffffffffffffstorage Temperature 0 .5 - 40 f¦ffffffffff -20 - 50 f¦ Relative humidity: f_ 80% fffffff_ 90% Power requirements Input: 98f+260 v ac, 50/60hz Consumption: f_ 80va About3.5-5.5kg/unit gross weight
8.4'/10.4'/12.1' high resolution industry color TFT LCD screen. Basic 7 standard parameters: ECG, NIBP, SpO2, RESP, 2-Temp, PR/HR. 5 lead, max 7 ECG wave forms display. Optional Futures: Touch screen WIFI 5AH lithium battery 2IBP ETCO2 Central monitoring system
Ys121s: Blood pressure Ecg Temperature Spo2 Ophthalmoscope Ent inspector Spen Keybord and mouse Build in printer Vital signs diagnosis data monitor system 12.1 lcd handwritten screen 6 modules Vital signs inspector, endoscopic inspector, eyesight inspector, color blindness inspector, medical record management, system management Shows Hr, rr, ecg waveform, rr waveform, pr, spo2, pulse strength, nibp, tempreture, glu, ua, cholesterol Infrared automatic inductive switch system Halogen bulbs, not easy to break but easy to change Pc tonngue depressor with special design Exclusive adopt front led cold source, different from The traditional rear cold source. 12.1 lcd handwritten screen Keyboard input, mouse operation, usb backup Creat download or delete medical record directly.
Dynamic ECG Monitor, is a lightweight and comfortable ambulatory adhesive patch suitable for real-time monitoring cardiac monitoring at home or in any healthcare environment. With one of the most effective methods of cardiac monitoring, can detect arrhythmia, abnormal heart rate or rhythm, providing complete waveform annotations, accurate parameters extraction, smart abnormality lock-up and rapid diseases information entry. As an intelligent medical-grade wearable ECG monitor, can be used in after-surgery tracking (health management) for cardiac patients and continuous monitoring for the elderly, extreme sports enthusiasts, people under high pressure, or the sub-healthy people as well.
Dynamic ECG Monitor, is a lightweight, comfortable ambulatory adhesive patch suitable for real-time monitoring cardiac conditions at home or in any healthcare environment. With one of the most effective methods of cardiac monitoring, can detect arrhythmia or abnormal heart rate or rhythm, providing complete waveform annotations, accurate parameters extraction, smart abnormality lock-up, and rapid diseases information entry.
Supplier: Wrist strap, heel grounder, wrist strap tester, wrist strap on-line monitor, constant monitor, combo tester, surface resistance meter
Supplier: Blood Pressure Monitors And Glucose Monitors
Buyer: Blood Glucose Meter Weight Scale Cannulla Iv Set Strips Sphygmomanometer