Technical specifications
Defibrillator
-defibrillator type: manual, synchronized, asynchronized,
-out put waveform: monophasic technology
-energy accuracy:
15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
3. SPO2 can testing for 0.1% Weak;
4. RA-LL impedance Respiration;
5. Trend Coexist Display;
6. OxyCRG Dynamic View Display;
7. Bed to Bed view Display;
8. Networking capacity and nurse calling system;
9. Options of printing, IBP, VGA and EtCO2;
10. UP to 4 hours working capacity of built-in rechargeable battery;
11.15" high resolution color TFT LCD display;
12. Large volume of tabular and graphic trends information storage and easy to recall;
13. Anti-ESU, anti- defibrillator;
14. Capture dynamic waveforms.
Technical specification:
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MO
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MO
Measuring Impedance Range: 0.3~5.0O
Base line Impedance Range: 0 – 2.5 KO
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
Specifications:
Automatic digital upper arm blood pressure monitor
Large lcd display
High quality
Automatic digital upper arm blood pressure monitor
Description
Upper arm blood pressure monitor
Display
Lcd digital display
Measuring principle
Oscillometric method
Measuring localization
Upper arm
Measurement range
Pressure
0-299mmhg(0-39.9kpa)
Pulse
40-199pulses/min
Accuracy
Pressure
±3mmhg(±0.4kpa)
Pulse
±5% of reading
Memory function
2*90 sets memory of measurement values
Power source
4 pcs aa alkaline battery or power adapter
Automatic power off
In 3 minutes
Battery life
Approx. 300 times for normal condition
Accessories
Instruction manual, storage box
Operating environment
Temperature
5-40°c
Humidity
15%-85%rh
Air pressure
86kpa-106kpa
Storage environment
Temperature
-20°c to 55°c
Humidity
10% to 85%rh
Avoid crash, sun burn or rain during transportation
Ar-325 anesthesia machine
Main body
High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application
Adult, child
Gas source
O2: 0.27--0.55mpa n2o: 0.27--0.55mpa
Flow meter
O2 : 0.1--1.0l/min 1.1--10l/min
N20: 0.1--1.0l/min 1.1--10l/min
Air : 0.1--10l/min
O2, n2o linkage and n2o stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure
Ttz-50/100/150 double dial platform scale
Max weighing: 50/100/150kg
Division:100g/200g/200g
G.W.:27kg n.W.:24kg
Measurement: 95×36×26cm
Platform size: 40×30cm