Ar-325 anesthesia machine
Main body
High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application
Adult, child
Gas source
O2: 0.27--0.55mpa n2o: 0.27--0.55mpa
Flow meter
O2 : 0.1--1.0l/min 1.1--10l/min
N20: 0.1--1.0l/min 1.1--10l/min
Air : 0.1--10l/min
O2, n2o linkage and n2o stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure
Technical data: Concentration range: Halothane : 0 to 5% Enflurane : 0 to 5% Isoflurane: 0 to 5% Sevoflurane: 0 to 8% Temperature range: Ambient and vapor temperature During operation 15 to 35oc During storage (empty, dry wick) -40 to 65oc Flow range 0.2 to 15l/min 0.2 to 10l/min (normal usage) for concentrations >5 vol.% Filling volume for anaesthetic agent: About 340 ml with dry wick About 300 ml with moist wick Maximum angle of tilt During transport (control dial at 0 ) any position and angle During operation straight up Warm up time: 5min Mounting type: Draeger plug in, selectatec compatible, cagemount (iso 23mm tapers), Fix mount, cagemount with interlock Filler type: Pour fil, easy-fil (isofulrane, halothane, enflurane) Pour fil, easy-fil, quik fil (sevoflurane) Standard: Ce, iso13485, iso9001, iso 8835-4, 93/42/eec mdd.
Product Description: Datex Ohmeda S/5 Aespire Clinician-inspired solutions help improve patient care Features - Enhanced monitor integration capabilities with our Datex-Ohmeda Anaesthesia Monitor and Compact Anaesthesia monitor - Lightweight and compact for easy manoeuvrability - Optional integrated auxiliary O2 flowmeter and suction control General Specifications: Dimensions - Height: 134.5 cm/52.9 in - Width: 72 cm/28.3 in - Depth: 73 cm/28.7 in - Weight: Approximately 108 kg/238 lb. Top shelf - Weight limit: 34 kg/75 lb. - Width: 66 cm/26 in - Depth: 40 cm/15.75 in Work surface - Height: 81.7 cm/32.2 in - Size: 2160 cm-2/334 in-2 DIN rail - Side of machine: 34.5 cm/13.6 in Drawers (internal dimensions) - Height: 17.5 cm/6.9 in - Width: 33 cm/13 in - Depth: 26.5 cm/10.4 in Absorber bag arm (optional) - Arm length: 30.5 cm/12 in - Bag arm height (adjustable): 87 cm (34.3 i) to 104 cm (40.9 in) Casters - Diameter: 12.5 cm/5 in - Brakes: Individual locking front casters Electrical Specifications Current leakage - 100/120 V: < 300¼A - Power - Power input: 100-120 Vac, 50/60 Hz - Power cord: Length: 5 m/16.4 ft. - Rating: 15A @ 120 Vac Inlet/outlet modules (120 V) - System circuit breakers: 15A - Outlets (optional): 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer Pneumatic Specifications Auxiliary common gas outlet - Connector: ISO 22 mm OD and 15 mm ID Gas supply - Pipeline input range: 240 kPa to 600 kPa/35 psig to 88 psig - Pipeline connections: DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O2, N2O, and Air, and contain pipeline filter and check valve. - Cylinder input: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted. - Primary regulator diaphragm minimum burst pressure: 2758 kPa/400 psig - Primary regulator nominal output: < 338 kPa/49 psig Pin indexed cylinder connections - < 407 kPa/59 psig DIN cylinder connections Environmental Specifications System operation - Temperature: 10° to 40°C/50° to 104°F - Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3 - Altitude: -440 to 3565 m/500 to 800 mmHg System storage - Temperature: -15° to 50°C/-5° to 122°F - Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3 - Altitude: -440 to 5860 m/375 to 800 mmHg - Oxygen cell storage: -15° to 50°C/5° to 122°F 10 to 95% relative humidity 500 to 800 mmHg Electromagnetic compatibility - Immunity: Complies with all requirements of EN 60601-1-2 - Emissions: CISPR 11 group 1 class B - Approvals: UL 2601-1 CSA C22.2 #601.1 EN/IEC 60601-1 CE 0197
Tidal Volume: 20-1500ml Working Mode: Semi open, Semi closed or Closed system Oxygen flush: 25L/min 75L/min High light LED display
Anesthesia Machine , Anesthesia workstation with two vaporizers and touch screen display. uses for infant, pediatric and adult application
Ce approved portable anesthesia machine Compact light-weight and portable, could be transported by pull-rod case, put on table and assembly on the trolley. Jackson or bains absorber is available Specifically designed to accomodate low flow Selectatec-bar and quick change vaporizer mounting device Visible inspiration and expiration valve Could upgrade to oxygen&n2o or oxygen&air flow meter freely Module rack with polyester medical material with superior spray technology, high strength and light weight. With transport case, convenient to take and transport Easy to disassemble and assemble all the components, convenient for clean and maintenance. Medical air compressor Low noise medical air compressor, very stable performance, safe and reliable Air compressor with lcd screen to display output pressure, provide safe, secure and permanent motivation Compact design and easy to transfer Assembled with clean control module, supplying cleaner and safer air to the patients Effective sound-absorbing materials Oil-free compressor with temperature protection Match with various ventilator of international standard in the world Size Weight
ARIES 2500 Anesthesia Machine: Display: 10.4 TFT color screen Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi~open, Semi~closed or closed system Anesthetic vaporizer: two high precise vaporizers Power supply: 220V,10%, 50Hz,1Hz 10V,10%, 60Hz,1Hz Internal battery: DC12V (4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator: Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform: P-t, F-t, V-t, F-v, V-p Tidal Volume: 20~1600ml Respiratory frequency: 1~65bpm I:E ratio: 4:1~1:4 Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc.. Alarm parameters: high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting: High pressure alarm set 1~60cmH2O. Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high: 21~99%. Low: 21~50%. MV alarm setting: MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit: Circle absorber: Compact circle absorber Flow meter: Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device, keep oxygen concentration not lower than 25% Oxygen flush: 25L/min~75L/min Gas source pressure: O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature: Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator: Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal Volume: 50 ~ 1600ml Breath frequency: 1 ~ 90BPM I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm Main Unit: Circle absorber: Compact circle absorber Bellow: 50 ~ 1600ml Oxygen FLUSH: 25L/min ~ 75L/min Flow meter: O2, N2O two-tube flowmeter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure: O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge: 2 units, one N2O, one O2.
Product Description 1. The comprehensive ventilation modes including PCV-VG, SIMV-PC provide more flexibility to ventilation strategy, suitable for various patients operation 2. Support both low-flow anesthesia and minimal-flow anesthesia 3. Electronic flow-meter, precise control and convenient operation 4. 12.1" TFT LCD with color touch screen, highlighted display 5.Certification: CE, ISO9001, ISO13485 Product Name 8700A Medical Anesthesia Machine Control Screen 12.1", TFT color touch screen Batteries and Operation time with fully charged DC24V, minimum.120 minutes Gas supply O2, N2O, AIR; 280kPa - 600kPa Cylinder yokes O2, N2O, AIR Fresh gas flow indicator Electronically display and virtual fresh gas flow tubes Ventilator Electronically controlled, pneumatically driven Compensation Compliance and Leak compensation, fresh gas compensation, altitude compensation Monitoring FiO2, Ppeak, Pplat, Pmean, PEEP, MV, Vti, Vte, Freq., Compliance, Resistance Graph Display P-t, F-t, P-V, V-t, Paw-V Loop, V-Flow Loop, optional CO2-t Optional CO2 module, Anesthetic gas module, ACGO, AGSS and so on
3 Gas (Oxygen, N2O & Air) Anesthesia Machine 7" Touch Screen Display Frame made up of MS Powder Coated Tidal Volume - 50-1500 ML Modes - CMV. ACMV, SIMV, PLV, Bag & Standby PEEP & FiO2 Monitoring 2 Hours battey back up