1. Main Features:
1. Input & output is fully insolated to endure impact of sensitive appliances and protect the inverter from being easily damaged.
2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads.
3. Soft start: Smooth start-up of the appliances.
4. Pure sine wave output waveform: Clean power for sensitive loads.
5. Low total harmonic distortion: Below 5%
6. Stable working performance: Even in the situation of under voltage or over voltage, the inverter could endure 10% voltage fluctuation until it shutdowns.
7. Cooling fan with internal temperature sensor will turn on automatically when the inverters becomes warm and turn off after the temperature dropped.
8. LED indicator on the front panel shows the working and error state.
9. Digital displays indicate battery voltage and inverter output voltage.
2. Protect functions:
1. Over load protection
2. Over current protection
3. Over voltage protection
4. Low voltage protection
5. Surge protection
6. Short circuit protection
7. High temperature protection
8. Reverse connection protection
9. External fuse protection
10. Buzzer alarm function
3. Applicable for: ( Solar/Wind/Home System )
1. Travel set equipment
2. Industrial equipment
3. Office equipment
4. Kitchen equipment
5. Household electrical equipment
6. Power tools
5. Technical Parameter:
Input:
Input voltage: DC12V/DC24V/DC48V
Working Voltage:
DC10V-15V/DC20V-30V/DC40V-60V
Input current: 166A/ 83A/41.67A
Standby input power: 2200W
Short circuit protection
Digital display Indicator:
Inverter woking: green light on
Inverter problem: no 110V/220v display
Charging indicator: digital of voltage up slowly
Charging process indicator: digital display charging voltage
Turn off the switch when charging which charging battery faster
Protection alarm:
Low input voltage alarm: buzzer
Low input voltage protection: no display, buzzer and inverter stop working
High input voltage protection: no output voltage display, have input display, inverter stop working.
Over load protection: voltage drop to 55V-140V
Abnormal temperature: no AC display, buzzer and stop working.
Environment:
High temperature protectioin: =70ºC
Working Temperature: -10ºC~40ºC
Cooling mode: Intelligent Temperature control Fan
Package included:
1* QW-P2000UPS
1* battery clamp
1* spare part
1* english user manual
1* standard packing box
4. Warranty: 12 months
Quality stanstard: CE, RoHS
1. Main Features: 1. Input & output is fully insolated to endure impact of sensitive appliances and protect the inverter from being easily damaged. 2. High Surge: High surge current capability starts difficult loads such as TVs, camps, motors and other inductive loads. 3. Soft start: Smooth start-up of the appliances. 4. Pure sine wave output waveform: Clean power for sensitive loads. 5. Low total harmonic distortion: Below 5% 6. Stable working performance: Even in the situation of under voltage or over voltage, the inverter could endure 10% voltage fluctuation until it shutdowns. 7. Cooling fan with internal temperature sensor will turn on automatically when the inverters becomes warm and turn off after the temperature dropped. 8. LED indicator on the front panel shows the working and error state. 9. Digital displays indicate battery voltage and inverter output voltage. 2. Protect functions: 1. Over load protection 2. Over current protection 3. Over voltage protection 4. Low voltage protection 5. Surge protection 6. Short circuit protection 7. High temperature protection 8. Reverse connection protection 9. External fuse protection 10. Buzzer alarm function 3. Applicable for: ( Solar/Wind/Home System ) 1. Travel set equipment 2. Industrial equipment 3. Office equipment 4. Kitchen equipment 5. Household electrical equipment 6. Power tools 4. Technical Parameter: Input: Input voltage: DC12V/DC24V/DC48V Working Voltage: DC10V-15V/DC20V-30V/DC40V-60V Input current: 333A/ 166A/83A Standby input power: 4200W Short circuit protection Digital display Indicator: Inverter woking: green light on Inverter problem: no 110V/220v display Charging indicator: digital of voltage up slowly Charging process indicator: digital display charging voltage Turn off the switch when charging which charging battery faster Protection alarm: Low input voltage alarm: buzzer Low input voltage protection: no display, buzzer and inverter stop working High input voltage protection: no output voltage display, have input display, inverter stop working. Over load protection: voltage drop to 55V-140V Abnormal temperature: no AC display, buzzer and stop working. Environment: High temperature protectioin: =70ºC Working Temperature: -10ºC~40ºC Cooling mode: Intelligent Temperature control Fan Package included: 1* QW-P4000UPS 1* battery clamp 1* spare part 1* english user manual 1* standard packing box 5. Warranty: 12 months Quality stanstard: CE, RoHS
Supplier: Voltage stabilizer, step up &down transformer, DC power supply, inverter, solar controller, battery charger
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Supplier: Pure sine wave power inverter, modified sine wave power inverter, UPS power inverter with charger, car power inverter, solar charge controller, solar panel, solar battery
Buyer: Solar charge controller
Supplier: Solar Batteries Batteries & Chargers Panels DC, AC Inverters & Converters Solar Inverters Solar Power System Solar Power Equipments Solar Panels Garden & Outdoor Furniture
Buyer: Solar Panels Batteries & Chargers Automotive Batteries DC, AC Inverters & Converters Solar Inverters Panels Solar Power Equipments
Specifications: Pure sine wave inverter Built-in mppt solar charge controller and battery charger Selectable input voltage range for home use Selectable charging current based on applications Configurable ac/solar input priority via lcd setting Compatible to mains voltage or generator power Auto restart while ac is recovering Overload and short circuit protection Smart battery charger design for optimized battery performance Cold start function Parallel operation with up to 6 units only available for 4000kva and 5000kva model
Supplier: Led lights, rechargeable batteries, led lights material, solar pcu, inverter, ups, solar system components
Services: Warehouse, shipment, clearing
5V 1A USB power charger travel adapter for mobile phone Item: AC DC adapter Input: 90-264V AC/47Hz-63Hz Output: 5V DC 2A Safety approvals: UL, PSE, CE AC plug type: AU/EU/US plug DC cable: 1.2m or depend on your demands DC size: 5.5*2.5mm/4.0*1.7mm/5.5*2.1mm/4.8*1.7mm Protection:9702;Short-circuit protection, over-current protection and over-voltage protection 9702;MTBF (mean time between failures): 50,000 hours Warranty: 1 year Functions:9702;Energy efficiency: V, VI 9702;Line regulation (full load): 161;¨¹5% 9702;Load regulation: 161;¨¹5% 9702;Ripple and noise: 161;¨¹100mV 9702;Hold-up time: 20ms (220V AC, typical) 9702;Rise time: 50ms full load (typical) 9702;Temperature coefficient:
Supplier: Uninterruptible power supply, solar inverter, battery and related accessories
Services: Transportation
Buyer: Battery