Jdy-338 gas detector
Induced gascoal gas\natural gas\lpg
Power input household power supply ac 220v /50hz or dc 12v
Working environment temp. -10¬ ~+40¬++ relative humidity _90%rh
Buzzer level:70db/m
Alarm density15%lel
Resume density8%lel
Stabilitylong-time working alarm density error_+ 5 %
Repetitiveness repetition test alarm density error_+5%
Alarm density error _5%lel
Alarm mode flash sound alarm, shut-off gas valve/network alarm signal
Power consumption_5w
11.9 x 6.8 x 4.6cm
0.32kg
Jdy-338 gas detector Induced gascoal gas\natural gas\lpg Power input household power supply ac 220v /50hz or dc 12v Working environment temp. -10+ ~+40++ relative humidity_90%rh Buzzer level:70db/m Alarm density15%lel Resume density8%lel Stabilitylong-time working alarm density error_+ 5 % Repetitiveness repetition test alarm density error_+5% Alarm density error_5%lel Alarm mode flash sound alarm, shut-off gas valve/network alarm signal Power consumption_5w 120mmlx70mmwx42mmh
Jdy-668 microwave & passive infrared detector Working voltagedc9~16v Working current25ma Working environment0¬~60¬ Alarm contactnc 28vd 80ma max Anti tamper contactnc 28vd 80ma max Alarm time optional5s10s or 30s Detection range12m Detection angle1100 Anti electromagnetic interference30v/m Anti light interference6500lux Installation height1.8~2.5m Dimension115 x 57 x 38mm Dimension115 x 57 x 38mm
Our detector is equipped with power and 2-step led indicators, which provide clear information about power and alarm. The state-of-the-art sensing element is ul approved, which ensures the reliability of the detector. The various models provide different solutions to protect household from any possible damage which might be caused from gas applications. You can also have ags-4xx series detecting both co and lng for a complete protection. This product series is CE approved. 120*41(mm), 310g
Basic features Mcu processing High stability sensor Ceiling mounted Independent & network option Direct current 12v Auto reset after alarm Technical parameter Detecting gas:town gas.Co Working voltage:12v dc Standby current:ín120ma Alarm current:ín60ma Alarm density:50í½300ppm Buzzer:í²70db(1m) Operating condition:-10íµí½+55íµ; relative humidityín90%rh Stability:regular alarm density erroría80ppm Repeatability:repeative alarm density erroría80ppm Alarm density error:ía80ppm Alarm mode:sound&flash alarm/network alarm signal Size:ª¦115íß51mm Packing:80pcs/ctn gw:16.6kgs d:515*335*520
"Operating voltage: AC110V or 220V Gas species: Natural gas or LPG Sensor: Semiconductor Wireless frequency: 315Mhz or 433Mhz Chip: 2262/1572 Drivable accessaries: Solenoid valve Alarm output: Sound & LED flash alarm&RF signal > adopted SCM from USA to ensure the stability, > intelligent circuit design, break-through anti-oil technology; "
"Operating voltage: AC110V or 220V Gas species: Natural gas or LPG Sensor: Semiconductor Wireless frequency: 315Mhz or 433Mhz Chip: 2262/1572 Drivable accessaries: Solenoid valve Alarm output: Sound & LED flash alarm&RF signal > adopted SCM from USA to ensure the stability, > intelligent circuit design, break-through anti-oil technology; "
12V D.Cauto-test for malfunctionAlarm Output: sound & flash alarm&relay output; ceiling mounted
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. adopted SCM from USA to ensure the stability, Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Can make 9V chargable back up battery "
Wasp-xm series pum-priming portable gas detector Outline Wasp-xm series pump-priming portable gas detector is a continuous monitoring of a variety of single gas detection equipment. This product is suitable for environmental monitoring, industrial production and other harmful gases working environment, which can effectively protect the health and safety of staff is not compromised. Main feature Smart probe design, calibration and Maintenance more convenient in the future; Fault, warning, operator error, alarm will be smart tips; Built-in cf calibration coefficients (voc measurements only valid); With audible alarm, visual alarm function, the status bar also displays alarm status; Full-color 3.5-inch tft screen, color lcd display and intuitive; Can be both digital and curve display of gas concentration in two ways; With usb communication port, you can speed 9600 bytes to communicate directly with the computer; With test record function, can store a month's measurement data and instrument or computer can view the data; With alarm recording function, you can record the last four times the alarm time and type; With calibration record; can record the last four times the size of the calibration time span; High-capacity lithium battery-powered, rechargeable, low battery automatic shutdown; Can be set high reported, underreporting, twa, stel, shutdown time, pump speed, etc.; Technical parameter Power supply: lithium battery (4.2v/3000mah) Operating current: normal current: ¡¡§1 150ma; alarm current: ¡¡§1 200ma 3¡¡¨¦operating environment: temperature: -40 ¡æ - 70 ¡æ Relative humidity: 15% - 95%, non-condensing 4¡¡¨¦storage environment: temperature: -20 ¡æ - 60 ¡æ