Basic features
Mcu processing
High stability sensor
Ceiling mounted
Independent & network option
Direct current 12v
Auto reset after alarm
Technical parameter
Detecting gas:town gas.Co
Working voltage:12v dc
Standby current:ín120ma
Alarm current:ín60ma
Alarm density:50í½300ppm
Buzzer:í²70db(1m)
Operating condition:-10íµí½+55íµ; relative humidityín90%rh
Stability:regular alarm density erroría80ppm
Repeatability:repeative alarm density erroría80ppm
Alarm density error:ía80ppm
Alarm mode:sound&flash alarm/network alarm signal
Size:ª¦115íß51mm
Packing:80pcs/ctn gw:16.6kgs d:515*335*520
Our detector is equipped with power and 2-step led indicators, which provide clear information about power and alarm. The state-of-the-art sensing element is ul approved, which ensures the reliability of the detector. The various models provide different solutions to protect household from any possible damage which might be caused from gas applications. You can also have ags-4xx series detecting both co and lng for a complete protection. This product series is CE approved. 120*41(mm), 310g
Jdy-338 gas detector Induced gascoal gas\natural gas\lpg Power input household power supply ac 220v /50hz or dc 12v Working environment temp. -10+ ~+40++ relative humidity_90%rh Buzzer level:70db/m Alarm density15%lel Resume density8%lel Stabilitylong-time working alarm density error_+ 5 % Repetitiveness repetition test alarm density error_+5% Alarm density error_5%lel Alarm mode flash sound alarm, shut-off gas valve/network alarm signal Power consumption_5w 120mmlx70mmwx42mmh
Wasp-xm series pum-priming portable gas detector Outline Wasp-xm series pump-priming portable gas detector is a continuous monitoring of a variety of single gas detection equipment. This product is suitable for environmental monitoring, industrial production and other harmful gases working environment, which can effectively protect the health and safety of staff is not compromised. Main feature Smart probe design, calibration and Maintenance more convenient in the future; Fault, warning, operator error, alarm will be smart tips; Built-in cf calibration coefficients (voc measurements only valid); With audible alarm, visual alarm function, the status bar also displays alarm status; Full-color 3.5-inch tft screen, color lcd display and intuitive; Can be both digital and curve display of gas concentration in two ways; With usb communication port, you can speed 9600 bytes to communicate directly with the computer; With test record function, can store a month's measurement data and instrument or computer can view the data; With alarm recording function, you can record the last four times the alarm time and type; With calibration record; can record the last four times the size of the calibration time span; High-capacity lithium battery-powered, rechargeable, low battery automatic shutdown; Can be set high reported, underreporting, twa, stel, shutdown time, pump speed, etc.; Technical parameter Power supply: lithium battery (4.2v/3000mah) Operating current: normal current: ¡¡§1 150ma; alarm current: ¡¡§1 200ma 3¡¡¨¦operating environment: temperature: -40 ¡æ - 70 ¡æ Relative humidity: 15% - 95%, non-condensing 4¡¡¨¦storage environment: temperature: -20 ¡æ - 60 ¡æ
Dega gas detector -stationary, compact - dega 04 Compact detector from new series, which substitute type DEGA 03,.Serves to one- or two- Level signalization of detected gas concentration in guarded area. Its construction, kind of installation and service is designed for use in smaller business, boiler rooms, garages etc.. Detector used semiconductance sensor, which transforms change of concentration of detected gas at change of electrical resistance.Exceed of pre-set limits is signalized optical, acoustic or with internal siren and switch of potential-free relays contacts. It ś possible to energize device with system voltage 230 V AC, 12 or 24 V DC.
Jdy-338 gas detector Induced gascoal gas\natural gas\lpg Power input household power supply ac 220v /50hz or dc 12v Working environment temp. -10¬ ~+40¬++ relative humidity _90%rh Buzzer level:70db/m Alarm density15%lel Resume density8%lel Stabilitylong-time working alarm density error_+ 5 % Repetitiveness repetition test alarm density error_+5% Alarm density error _5%lel Alarm mode flash sound alarm, shut-off gas valve/network alarm signal Power consumption_5w 11.9 x 6.8 x 4.6cm 0.32kg
Product description This product is wireless gas detector (hereinafter called detector), can be used for all kinds of anti-theft alarm system, used to detect gas leak, when gas concentration reached alarm standard, detector will alert immediately, meanwhile send alarm signal to alarm host thought wireless, so as to achieve the aim of anti-theft alarm
Introduction: Portable gas detector GC510 can detect toxic gas, combustible gas, oxygen gas, etc in the working site continuously. It is widely applicable to such application where is explosion-proof, toxic gas leakage emergency rescue, underground or mine, etc, to avoid workers’ life and safety being aggrieved,the equipment being damaged . GC510 can be equipped with built-in air pump to extract air and test the air sample in the testing area, then transfer the air sample into the gas detector , which is with rapid detection speed. Long distance detection can be performed in the dangerous area to ensure the worker’s safety. The dispersive gas detection can be operated in the special short distance environment and confined pipes by the external flexible probe( can detect combustible gas only for now) Characteristics: Small size, light weight and durable Adopt embedded 16-bit microprocessor, ensure that the product is in stable and reliable operation. Visual, audible, vibration alarm. Chinese or English menu is optional. Large display screen, easy operation. Self-test function. 1000 alarm records storage. Save and restore the factory setting function. External flexible probe(Optional) for combustible gas only. Embedded air pump(Optional).
Hd1000a is a new standalone ac powered plug-in combustible gas detector From henan chicheng electric co., ltd to protect you and your family from the Dangers of explosive gas such as natural gas(methane) and lpg. It adopts Highly accurate catalytic gas sensor and utilizes sophisticated electronic Components, offering a high level of functionality, reliability and flexibility. Hd1000a is complete with a special circuit that control the catalytic sensor¡¡¥s Efficiency level, and signals any possible fault and it has power, pre-heat, fault And alarm indications.
Single Gas Detector A single-gas detector is a device that detects the presence of any gas within an area, usually as part of a safety system. This type of Single-Gas Detector Equipment is used to detect a gas leak and interface with a control system so a process can be automatically shut down. A gas detector can also alert operators in the vicinity of the leak, allowing them to leave the area. We supply an immense choice of gas finders and screens for various applications like oxygen, combustible gases, and carbon monoxide. The gas detector adopts an embedded MCU controller detector adopts and is easy to operate, These units can be provided with sensors to recognize the most well-known gases as well as a scope of more extraordinary gases for changing applications. VS-70 xx portable gas detector locators are additionally accessible with a PID sensor to identify the presence of volatile natural compounds and with infrared IR sensors for the estimation of CO2 and other combustible gases. FEATURES : Single gas detector individually we can provide gas detectors for the following gases: Oxygen Combustible Gases LPG Hexane Hydrogen Carbon Monoxide Hydrogen Sulphide Chlorine Sulfur Dioxide Ammonia Hydrogen Chloride Hydrogen Nitric Oxide Nitrogen Dioxide Ethylene Phosphine Phosgene Ozone And Many More