Model : WGQH high voltage cage motor soft start / soft stop
Description: National patent owned ,digital intelligent control
1) Main function
High voltage motor will creat big shake if start or stop directly, heavily influence the motor service life and loaded equipment , some times motor burnt .
WGQH motor soft start/ stop is high-tech national patented product .
1) reduce motor start current, high efficient in saving power
2)much motor protection function (as following introduction)
3)easy install, free maintenance, save maintenance cost
4)highly increase the motor service life
5)accurate setup start torque /start current/start time/ stop time/ etc
6) can connect to computer, PLC
2)USING AREA:
suitable motor AC squirrel cage motor
Rated voltage <=10KV
Rated current 75A ~ 600A
Rated power 500KW ~11000KW
cabinet size mm 2300X1300X1560
working condition ( if special, pls clarify) temperature -20C ~ + 50C
air humidity <=90%
Altitdue normal 2000m
power frequency 50Hz +/-2Hz
3)Working principle:
1> IT adopts DSP controlling technique,power and electron technique, and multiple SCR series/parallel to motor, to protect the motor completely.
2> it has a high effect of over 96%(top to 97%)
3>:the device combines series¶llel thyristor, professional insulating material imported with original packing and modern power& electric control technology
4)Unique Feature:
1> It perfectly protect the stator and motor from faults like short circuit, over current,current limiting, over-voltage, under-voltage,over load, open-phase, 3 phase unbalance, over heat, communication fault,
2>the main circuit is equippment with component-based structure,modularized installation method, can reach the target of multiiple onver-voltage absorption and protection.
3>it multiply limiting the clamp of transient dv/dt, lighting impulse voltage,operation wave over-voltage and that of transient transition process. it has unique measure and methos to reach pressure balancing of di/dt, valve recanalizing and turn-off.
4>different current intensities are isolated perfectly, the system adopts high anti-interferential digital contactor, matched with fiber/CT isolation transforming technology, which help to avoid interference of each current, making the high voltage performance is as reliable and safe .
5>:the specially designed fault detection return and judging system can pass the detecting result to the control circuit in time and start the sound and light alarm
6>unique heat dissiipation design can effectively cool the thyristor and machine
7>it is of small volume, low power dissipation, high sensitivity, and non-contact and so on, also easy to install.
wooden case.
Wgqh series of high voltage solid soft starter Performance characteristics The device combines series & parallel thyristor, professional insulating material imported with original packing and modern power & electric control technology, which is applicable to large and medium high voltage soft starting equipments with motor.
Jjr3000 series intelligent soft starter adopts international advanced electronics technology, mcp technology and modern control theory to efficiently limit start voltage of asynchronous motor. The equipment could be widely applied to fan, pump, conveyor, and compressor and other heavy load equipment. It is an excellent product to substitute traditional startup equipments such as star/triangle transition, self -coupling voltage reduction, magnetron voltage reduction and so on.
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Supplier: Low voltage power cables, mid voltage power cables, control cables, instrumentation and telecommunication cables, optical fiber cables, mine low voltage power cables, mine mid voltage power cables, rail transit communication cables, railway rolling stock cables, cables for use in photovoltaic systems, fireproof cable, low voltage power cables for shipboard and offshore, mid voltage cables for shipboard and offshore, control cables for shipboard and offshore, instrumentation and telecommunication cables for shipboard and offshore compensating extension cables and compensating cables, rubber sheathed cable, charging post cable, connecting cables for equipment, towline cables, high temperature resistant cable,esp power cable, (electrical submersible pump power cable), mining detection cable, logging cable, submarine power cable
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
Model: Efficient 75kw to 10000kw AC wound rotor motor soft starter 1) direct starting problem motor will create big current shake if start directly ( 5-8 times more than rated current), it makes big strike for electic grid and loaded equipment, heavily reduce motor and equipment service life,Sometimes motor burnt .so,stepless smooth start and stop is neccessory 2) intelligent WYQ6 main function 1:smooth start, without shook to equipment, extend the using life,save equipment maintain cost 2:reduce start current, reduce temperature increasing of motor, largely extend the long of motor, 3:Full protect motor and loaded equipment 3)range of application: suitable to heavy load soft starting of wound rotor asynchronous motor, especially in industrial or mines with unstable or lower voltage 4)unique feature: 1: low starting current: the starting current is