Specifications
8.4" color TFT display, up to 10 waveforms
One level menu, easy to use
Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
Maximum 720 hour graphic and tabular trends of all parameters
Built-in recorder and battery
Suitable for adult, pediatric and neonatal patient
Arrhythmia analysis, ST calculation, Pace analysis
Anti-ESU, anti- defibrillator
Standard network interface, can connect to Central monitor system
Optinal: recorder, dual IBP.
Packing size: 30x34x31cm Weight: 5.2kg.
Specifications 12" color TFT display, up to 12 waveforms One level menu, easy to use Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional) Maximum 720 hour graphic and tabular trends of all parameters Built-in recorder and battery Suitable for adult, pediatric and neonatal patient Arrhythmia analysis, ST calculation, Pace analysis Anti-ESU, anti- defibrillator Standard network interface, can connect to Central monitor system Optinal: recorder, dual IBP, CO2. Packing size: 27x49x39cm Weight: 8.5kg.
Specifications 15" color TFT display, up to 14 waveforms One level menu, easy to use Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional) Maximum 720 hour graphic and tabular trends of all parameters Built-in recorder and battery Suitable for adult, pediatric and neonatal patient Arrhythmia analysis, ST calculation, Pace analysis Anti-ESU, anti- defibrillator Standard network interface, can connect to Central monitor system Optinal: recorder, dual IBP, CO2, GAS, IoC. Packing size: 30x46x44 Weight: 10kg.
Technical data: Oxygen flow:0.5-5L/min Oxygen concentration:95.5%-87% Output pressure: 40-70kPa Pressure relief mechanism operational at: 250kPa + 25kPa Operation nose Level
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg
Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
Basic Info. Model NO. BVM-8 Parameter SpO2, Pulse Rate, NIBP Battery Build in Rechargeable up to 15 Hours Running Application Adult, Pediatric, Infant, Neonate Power AC:100V-240V 50/60 Hz Trademark BENEMED Transport Package Carton with Foam Specification 210mmx170mmx75mm Origin China HS Code 9018199000 Product Description Customer Question & Answer BENEMED Portable Vital Sign monitor NIBP, SPO2, RESP Parameters BVM-8 Portable NIBP SpO2 Medical Vital Signs Patient Monitor Bvm-8Prodct Parameters: 1. Dimension and Weight -- Dimension: 210mm 170mm 75mm -- Net Weight: 1 kg Display Specification -- LED + LCD -- LCD Size: 85mm * 30mm 2.Power Supply AC Power Adaptor -- Voltage: AC100 ~ 240V, 50/60Hz -- Adapter: Output 5VDC, 4A Battery -- Type: Rechargeable Lithium battery 3.7V/2200mAh -- Charge Cycl: 500 times -- Working time: 3 hours -- Optional large battery for 8-9 hours work 3. Environment Temperature -- Working: 5 ~ 40 C -- Transport and Storage: -20 ~ 50C Humidity -- Working: 15 ~ 80 % (non-condensing) -- Transport and Storage: 10 ~ 90 % (non-condensing) Atmosphere pressure -- Working: 86 KPa ~ 110 KPa -- Transport and Storage: 86 KPa ~ 110 KPa 4.Monitoring Parameter NIBP -- Method: Oscillometric -- Mode: Manual, Auto, STAT -- Measuring Interval in AUTO Mode: 1 ~ 480 min -- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval -- Measure and Alarm Range: Adult: SYS: 30 ~ 270 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 235 mmHg Pediatric: SYS: 40 ~ 235 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 225 mmHg Neonate: SYS: 30 ~ 135 mmHg DIA: 10 ~ 110 mmHg MEAN: 20 ~ 125 mmHg -- Static pressure accuracy: ±3mmHg -- Resolution: 1mmHg -- Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation 8mmHg -- Over pressure Protection: Dual protection via software & hardware SpO2 SpO2 -- Measuring Range: 0 ~ 100% -- Resolution: 1 % -- Support Pitch tone and multi-level volume -- Accuracy: ±2% (80 ~ 100%), ±3% (70 ~ 80%), unspecified (0~ 69%) -- PI range: 0.075% ~ 20% Pulse Rate -- Measuring and Alarm Range: 25 ~250bpm -- Resolution: 1bpm -- Accuracy: ±1bpm or ±1 bpm, whichever is greater 5.Trend and Review -- Trend: 100 hours of patient SpO2 -- NIBP measurement reviewing: 500groups 6.Alarm -- Level: Low, mesium, high -- Indication: Auditory and visual -- Alarm volume adjustable 7.System Output -- Ethernet Network: standard RJ45 socket*1 -- USB Port*1
Specifications: Individually pack in a corrugated box with Accessories Adult, Paediatric & Neonatal monitoring Arrhythmia detection and alarm prioritization facility Drug dose calculation and Titration Table ST segment analysis Electrocautery & Defibrillator Protected 2 Hrs battery back-up Networking capability 2-Channel IBP monitoring (optional) Respironics Capnography Monitoring (optional) 2-Channel Thermal Printer (optional)
Specifications: Individually pack in a corrugated box with Accessories Adult, Paediatric & Neonatal monitoring Arrhythmia detection and alarm prioritization facility Drug dose calculation and Titration Table ST segment analysis Electrocautery & Defibrillator Protected 2 Hrs battery back-up Networking capability 2-Channel IBP monitoring (optional) Respironics Capnography Monitoring (optional) 2-Channel Thermal Printer (optional)
Specifications: Individually pack in a corrugated box with Accessories Adult, Paediatric & Neonatal monitoring Arrhythmia detection and alarm prioritization facility Drug dose calculation and Titration Table ST segment analysis Electrocautery & Defibrillator Protected 2 Hrs battery back-up Networking capability 2-Channel IBP monitoring (optional) Respironics Capnography Monitoring (optional) 2-Channel Thermal Printer (optional)