Basic Info.
Model NO.
BVM-8
Parameter
SpO2, Pulse Rate, NIBP
Battery
Build in Rechargeable up to 15 Hours Running
Application
Adult, Pediatric, Infant, Neonate
Power
AC:100V-240V 50/60 Hz
Trademark
BENEMED
Transport Package
Carton with Foam
Specification
210mmx170mmx75mm
Origin
China
HS Code
9018199000
Product Description
Customer Question & Answer
BENEMED Portable Vital Sign monitor NIBP, SPO2, RESP Parameters BVM-8
Portable NIBP SpO2 Medical Vital Signs Patient Monitor Bvm-8Prodct Parameters:
1. Dimension and Weight
-- Dimension: 210mm 170mm 75mm
-- Net Weight: 1 kg
Display Specification
-- LED + LCD
-- LCD Size: 85mm * 30mm
2.Power Supply
AC Power Adaptor
-- Voltage: AC100 ~ 240V, 50/60Hz
-- Adapter: Output 5VDC, 4A
Battery
-- Type: Rechargeable Lithium battery 3.7V/2200mAh
-- Charge Cycl: 500 times
-- Working time: 3 hours
-- Optional large battery for 8-9 hours work
3. Environment
Temperature
-- Working: 5 ~ 40 C
-- Transport and Storage: -20 ~ 50C
Humidity
-- Working: 15 ~ 80 % (non-condensing)
-- Transport and Storage: 10 ~ 90 % (non-condensing)
Atmosphere pressure
-- Working: 86 KPa ~ 110 KPa
-- Transport and Storage: 86 KPa ~ 110 KPa
4.Monitoring Parameter
NIBP
-- Method: Oscillometric
-- Mode: Manual, Auto, STAT
-- Measuring Interval in AUTO Mode: 1 ~ 480 min
-- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-- Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
-- Static pressure accuracy: ±3mmHg
-- Resolution: 1mmHg
-- Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
-- Over pressure Protection: Dual protection via software & hardware
SpO2
SpO2
-- Measuring Range: 0 ~ 100%
-- Resolution: 1 %
-- Support Pitch tone and multi-level volume
-- Accuracy: ±2% (80 ~ 100%), ±3% (70 ~ 80%), unspecified (0~ 69%)
-- PI range: 0.075% ~ 20%
Pulse Rate
-- Measuring and Alarm Range: 25 ~250bpm
-- Resolution: 1bpm
-- Accuracy: ±1bpm or ±1 bpm, whichever is greater
5.Trend and Review
-- Trend: 100 hours of patient SpO2
-- NIBP measurement reviewing: 500groups
6.Alarm
-- Level: Low, mesium, high
-- Indication: Auditory and visual
-- Alarm volume adjustable
7.System Output
-- Ethernet Network: standard RJ45 socket*1
-- USB Port*1
Technical data: Oxygen flow:0.5-5L/min Oxygen concentration:95.5%-87% Output pressure: 40-70kPa Pressure relief mechanism operational at: 250kPa + 25kPa Operation nose Level
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg
Specifications 8.4" color TFT display, up to 10 waveforms One level menu, easy to use Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional) Maximum 720 hour graphic and tabular trends of all parameters Built-in recorder and battery Suitable for adult, pediatric and neonatal patient Arrhythmia analysis, ST calculation, Pace analysis Anti-ESU, anti- defibrillator Standard network interface, can connect to Central monitor system Optinal: recorder, dual IBP. Packing size: 30x34x31cm Weight: 5.2kg.
Specifications 12" color TFT display, up to 12 waveforms One level menu, easy to use Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional) Maximum 720 hour graphic and tabular trends of all parameters Built-in recorder and battery Suitable for adult, pediatric and neonatal patient Arrhythmia analysis, ST calculation, Pace analysis Anti-ESU, anti- defibrillator Standard network interface, can connect to Central monitor system Optinal: recorder, dual IBP, CO2. Packing size: 27x49x39cm Weight: 8.5kg.
Specifications 15" color TFT display, up to 14 waveforms One level menu, easy to use Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional) Maximum 720 hour graphic and tabular trends of all parameters Built-in recorder and battery Suitable for adult, pediatric and neonatal patient Arrhythmia analysis, ST calculation, Pace analysis Anti-ESU, anti- defibrillator Standard network interface, can connect to Central monitor system Optinal: recorder, dual IBP, CO2, GAS, IoC. Packing size: 30x46x44 Weight: 10kg.
Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
Specifications: Individually pack in a corrugated box with Accessories Adult, Paediatric & Neonatal monitoring Arrhythmia detection and alarm prioritization facility Drug dose calculation and Titration Table ST segment analysis Electrocautery & Defibrillator Protected 2 Hrs battery back-up Networking capability 2-Channel IBP monitoring (optional) Respironics Capnography Monitoring (optional) 2-Channel Thermal Printer (optional)
Specifications: Individually pack in a corrugated box with Accessories Adult, Paediatric & Neonatal monitoring Arrhythmia detection and alarm prioritization facility Drug dose calculation and Titration Table ST segment analysis Electrocautery & Defibrillator Protected 2 Hrs battery back-up Networking capability 2-Channel IBP monitoring (optional) Respironics Capnography Monitoring (optional) 2-Channel Thermal Printer (optional)
Specifications: Individually pack in a corrugated box with Accessories Adult, Paediatric & Neonatal monitoring Arrhythmia detection and alarm prioritization facility Drug dose calculation and Titration Table ST segment analysis Electrocautery & Defibrillator Protected 2 Hrs battery back-up Networking capability 2-Channel IBP monitoring (optional) Respironics Capnography Monitoring (optional) 2-Channel Thermal Printer (optional)