Purpose
The instrument is designed and made as per the National Standard GB/T3536 ¡°Test Methods for Flash Point and Fire Point of Petroleum Products (Cleveland Open Cup Methods), and T0651 ¡°Asphalt Flash Point and Fire Point Test (Cleveland Open Cup Methods)¡± in the Industry Standard JTJ052 Specification and Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering. It is used to determine flash point of petroleum products and bituminous materials, excepting fuel oil and materials having a flash point of lower than 79 ¡æ.
Adopt microprocessor techniques and equipped with advanced system software, it can control temperature, apply flame, ignite, detect flash point, and print out test data automatically. It has a 6 digits display. 4 digits for temperature display and the other 2 digits for time display.
Technical parameters
(I) Operation condition
1. Ambient temperature: 20¡À5¡æ
2. Relative humidity: < 80%
3. Power supply: AC 220V¡À10£¥, 50¡À1Hz
(II) Temperature measurement
1. Measurement range: ambient temperature~350¡æ
2. Test accuracy: 0.2%
3. Resolution: 0.1¡æ
4. Repeatability:
(1) Flash point is lower than 150 ¡æ: error is less than 4 ¡æ
(2) Flash point is higher than 150 ¡æ: error is less than 6 ¡æ
(III) Basic parameters:
1. Speed rising speed: as per GB/T 3536-83
2. Ignition mode: By a gas flame (4 mm)
3. Total power consumption: not more than 400 W.
Place of Origin: Chongqing, China (Mainland) Brand Name: TOP Model Number: ACD-3000I Power: Electronic Usage: Auto Testing Machine Type: Fully Automatic Oil Acidity Tester Condition: New Method of Display: 7 inch color LCD Testing Range: 0.0005~0.5000mgKOH/g Power supply: 220V±10%,50Hz±5% Environmental Humidity:
The instrument is designed and made as per GB/T261 ¡°Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)¡±. It is used to determine the lowest temperature of a petroleum product sample when the mixture of sample vapor and air around the sample contacts flame and flashes when heated in a closed cup under stipulated condition. The lowest temperature is the flash point of the petroleum product sample. The instrument has function of automatic program temperature controlling, automatic barometric pressure modification, and modified value calculation. It can automatically control measurement procedures and test data, and it can also save, analyze and print out test data. Technical parameters 1. Power supply: AC 220V¡À10%, 50Hz. 2. Temperature measurement: (1) Measurement range: ambient temperature~250 (2) Flash point is lower than 104 ¡æ, error is 2 Flash point is higher than 104 ¡æ, error is 6 (3) Resolution: 0.1 (4) Precision: 0.5% 3. Basic parameters: (1) Temperature rising rate: as per GB/T261 (2) Ignition mode: gas flame is 3~4©L 4. Ambient temperature: 10~40 5. Relative humidity: ¡Ü80£¥ 6. Total power consumption: not more than 350 W.
Automatic Closed Flash Point Tester used to measure the Closed flash point value of petroleum products.Advanced foreign technology is adopted. LCD TET's pure color touch screen displays the man-machine dialogue interface in Chinese. For parameters such as prevalue temperature oil test label atmospheric pressure and test date it has prompt menu prompt input which is convenient and fast.It is an ideal substitute for imported instruments.Widely used in railway aviation electric power petroleum industry and scientific research departments.
DSY-202ZA is the second generation instrument that is designed according to GB/T261 and ASTM D93; it is suitable to the determination of flash point of petroleum products automatically. Characteristic: 1. Igniting method can be by electricity and gas option. 2. MCU controlled, igniting, detecting and judgment of flash point, printing automatically, Touch screen display. 3. Display test status in real time 4. Set the expected flash point, the highest flash point, ignition times, detection sensitive 5.Built-in barometer pressure sensor, it can be calibrated barometer pressure in test result according to the measure barometer pressure 6. Automatic lifts arm to the complete upright position after testing 7.Easy to remove the detection device by hand, and easy to repair and clean 8. The sliding plate that is on the test cup cover, which can be removed easily, and can be cleaned each time, make the result more accuracy
DSY-202ZA is the second generation instrument that is designed according to GB/T261 and ASTM D93; it is suitable to the determination of flash point of petroleum products automatically. Characteristic: 1. Igniting method can be by electricity and gas option. 2. MCU controlled, igniting, detecting and judgment of flash point, printing automatically, Touch screen display. 3. Display test status in real time 4. Set the expected flash point, the highest flash point, ignition times, detection sensitive 5.Built-in barometer pressure sensor, it can be calibrated barometer pressure in test result according to the measure barometer pressure 6. Automatic lifts arm to the complete upright position after testing 7.Easy to remove the detection device by hand, and easy to repair and clean 8. The sliding plate that is on the test cup cover, which can be removed easily, and can be cleaned each time, make the result more accuracy
Product Name Fashion Consumable Personal Protection Particulate N95 Mask Material Non woven fabric+ Melt Blown Filter+ Non Woven Fabric Shape Molded Cup/Cone Application Farm buildings, Mining, Weaving,Polishing,Pharmacy,Hardware,Cement Size 190*130mm Carton size 310*200*145mm Packing details 50pcs/Carton Product's details Adjustable aluminum nose clip to offer better fit
We supply attractive variety qualitative range of Toilet and Bathroom accessories. Features of our Shower door hinges · CNC machined precision pivot pins · Dimension 90mmx 55mm (varies from hinge to hinge) · Chrome plated, Brushed Nickel, Brass Polished, Polished Chrome, Gold Plated, Oil Rubbed Bronze. · Solid brass, Zinc as per customer choice. · Glass to Glass, wall to Glass shower door hinges. · Closing angles 90°, 135°,180°degree. · Straight edges, beveled edges, round edges. · Glass preparation- Mickey Mouse ear, square and round glass cut. · Glass thickness 8mm-12mm. · Glass door weight 35~36Kgs with two hinges. · Glass door weight 54Kgs with three hinges. · Also available in some models of shower door hinges with adjustable hinges. · Also available in auto- self closing for some models. · Also available in Bi-fold Hinge.
1> Feature : Adjustable 2> 90° wall mount hinge , 180° glass to glass 3> Glass thickness : 8 mm~12 mm 4> Max door weight : 36 kg (with 2 hinges) 5> Material : Solid Brass 6> Some models do have auto self-closing function within 25° at both sides 7> Mickey Mouse ear design.