We offer a range of UV Fluorescent Fibre for security, identification, coding and anti-counterfeiting applications.
These fibre are not noticeable when incorporated into papers. When irradiated with UV light, these fibre emit fluorescence of red, blue, yellow, green colors and so are immediately identifiable.
Some of the common applications are in postage stamps, currency notes, lottery tickets, security pass, etc.
Catalogue Number Product Name Type Appearance UV Fluorescent Color ª-ex ª-em
SE2215 UV Fluorescent Fibre Red White fibre Red 365nm 610í+5nm
SE2216 UV Fluorescent Fibre Blue White fibre Blue 460í+5nm
SE2217 UV Fluorescent Fibre Yellow White fibre Yellow 525í+5nm
SE2218 UV Fluorescent Fibre Green White fibre Green 510í+5nm.
Optical brighteners, also known as fluorescent whitening agents (FWAs) or optical brightening agents (OBAs), are chemical compounds used in various industries, primarily in textiles, paper, and detergents. These substances absorb ultraviolet (UV) light and re-emit it as visible blue light, making colors and whites appear brighter and more vivid. Optical brighteners are often added to laundry detergents to give the illusion of cleaner and whiter clothing by enhancing their visual brightness. They are also used in the paper industry to improve the brightness and whiteness of paper products. Optical brighteners' ability to improve the appearance of materials under certain lighting conditions makes them valuable in enhancing the visual quality of a wide range of consumer and industrial products.
We can offer a range of UV Fluorescent Pigment for security, identification, coding and anti-counterfeiting applications.
These pigments are neutral in color, with a white to off-white powder appearance, and are not noticeable when incorporated into security inks, fibre and papers. When irradiated with UV light, these pigments emit fluorescent radiation of yellow, green, red, blue colors and so are immediately identifiable.
Some of the common applications are in postage stamps, currency notes, credit cards, lottery tickets, security passes, etc.
A similar range of pigments are also offered for architectural decoration applications, such as in hotels and restaurants, discotheques and night clubs, gymnasiums and other public entertainment places for outstanding visible effects. Details are available on request.
Catalogue Number SE2211 SE2212 SE2213 SE2214
Product Name UV Fluorescent Pigment UV Fluorescent Pigment UV Fluorescent Pigment UV Fluorescent Pigment
Type Red Yellow Green Blue
Appearance Baby pink Solid Powder Off-white
Powder Buff Solid Powder Off-white
Powder
UV Fluorescent Color Red Yellow Green Blue
Solubility in Water Insoluble Insoluble Insoluble Insoluble
ª-ex 365nm.
Product Application
1. Standards for titration of alkali and iodometric methods. Fluorescent indicator. Complex indicator.
2. This product is used as a scorch retarder in the rubber industry and produces UV absorbers and foaming agents.
3.Salicylic acid is used as a fluorescent indicator, with an indicator, with a masking agent. Titanium, zirconium, tungsten Plasma developer and preservative.
4. Salicylic acid is used as an additive in some weakly acidic electrolytes and as a complexing agent for electroplating or electroless plating.
5. Cosmetic preservatives. Mainly used in water cosmetics such as toilet water, garden water, quini ne head water. In addition to antiseptic and bactericidal effects, there are functions such as removing sweat odor, relieving itching and swelling, relieving pain and reducing inflammation. 8. A small amount is used to prepare daily flavors such as animal flavors. It is used in foods and acts as a preservative.
This product is used for whitening treatment of polyvinyl chloride, polystyrene, ABS resin, polyolefin and polyester, and is also used for whitening cellulose acetate, polymethyl methacrylate and foam artificial leather. It is also used in varnishes, paints, UV-curable coatings, printing oils, inks, fats, oils, and packaging materials. This product can be used as an anti-counterfeiting mark when applied in printing inks. It can be used in photography to enhance the whiteness of the non-image areas of the photo and can transform the photo into fluorescence when exposed to ultraviolet light. Produce a whitening and brightening effect.
Polyether polyols are key components used in the production of polyurethanes.
Polyether-based polyurethanes exhibit enhanced hydrolytic stability and excellent resistance to weak acids and bases compared to polyester-based polyurethanes.
Polyether polyurethane can be divided into soft foam polyether, rigid foam polyether, and elastomer with polyether according to the performance of polyether products.
However, polyether-based polyurethanes are more susceptible to UV radiation and provide poor resistance to oils and fuels compared to polyester-based polyurethanes.
Application:
Polyether polyols' major use is in polyurethane foams. Flexible foams are primarily used in cushioning applications such as furniture, bedding and car seats, and in carpet underlay. Rigid foam's largest consumer is the construction industry where it is mostly used for insulation. Rigid foam is also used in commercial refrigeration and packaging. Smaller uses for polyether polyols include elastomers, adhesives and sealants, surface coatings and polyurethane fibres.
FDR-3301 UV fluorescence sulfur analyzer
Scope
This instrument is a new generation of precision instruments developed in combination with the principle of UV fluorescence measurement and computer technology. It is the most advanced total sulfur analyzer in China. It conforms to ASTM D5453, SH / T 0689 and other standards. The instrument complies with national refined oil Arbitration standard for determination of total sulfur content. It widely used in the determination of crude oil, hydrocarbons and engine fuel, LPG, plastics, petrochemical products, food and so on.
The instrument uses the principle of ultraviolet fluorescence measurement, when the sample is introduced into the pyrolysis furnace, the sample undergoes the cracking oxidation reaction, in which the sulfide is quantitatively converted into sulfur dioxide, carried by the carrier gas, the moisture is removed by the membrane dryer, (SO2 *), when the SO2 * return to the steady state of sulfur dioxide emission fluorescence, the release of energy received by the photomultiplier tube, and then amplified by the micro-current amplifier, and then to the SO2 * The amount of sulfur dioxide is proportional to the total sulfur content in the sample, so the total sulfur content in the sample can be determined by measuring the luminous intensity of the sample.
Features
1, computer control, it can achieve man-machine dialogue, data and peak shape can be automatically stored and printed.
2, the operating software and LIMIS system can be connected to achieve automatic data transmission.
3, the instrument uses a new quartz cracking tube, which can increase the injection volume, reduce measurement error, improve the sensitivity of the instrument, higher repeatability.
4, cooling fan can automatically turn on and off, so you can save the trouble of waiting for shutdown, saving time and effort.
5, the darkroom system uses the latest technology, the key components of imported detection components to improve the instrument's detection accuracy and sensitivity.
6, the instrument uses imported film dryer to absorb water, eliminating the need to replace the frequent trouble of magnesium perchlorate, while reducing the leakage problem.
7, the instrument uses computer-controlled temperature, improve the accuracy of the instrument temperature control, and difficult to over-temperature.
8, the instrument uses air-cooled instead of water-cooled, saving water resources.
9, the user can retrieve the existing calibration curve, after use the standard sample to calibration it, you can analysis sample.
Technical Parameters
1, standards: ASTM D5453, SH/T 0689 and other standards
2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage
3. Air source: Argon: 99.999%, Oxygen: 99.999%
4, sample status: solid, liquid, gas (with corresponding injector)
5, temperature range: room temperature ~ 1100 ± 3
6, repeatability error: 0.2mg / L X
Scope
UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on.
Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity.
Features
1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print.
2, the operating software can be connected with LIMIS system, automatic data transmission.
3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability.
4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort.
5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument.
6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem.
7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature.
8, using air instead of water cooling, saving water resources.
9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis.
Technical Parameters
1, in line with standards: ASTM D5453, SH / T 0689 and other standards
2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage
3. Air source: Argon: 99.999% Oxygen: 99.999%
4, sample status: solid, liquid, gas (with corresponding injector)
5, temperature range: room temperature ~ 1100 ? ± 3 ?
6, repeatability error: 0.2mg / L=X
Scope
UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on.
Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity.
Features
1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print.
2, the operating software can be connected with LIMIS system, automatic data transmission.
3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability.
4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort.
5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument.
6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem.
7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature.
8, using air instead of water cooling, saving water resources.
9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis.
Technical Parameters
1, in line with standards: ASTM D5453, SH / T 0689 and other standards
2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage
3. Air source: Argon: 99.999% Oxygen: 99.999%
4, sample status: solid, liquid, gas (with corresponding injector)
5, temperature range: room temperature ~ 1100 ? ± 3 ?
6, repeatability error: 0.2mg / L=X