DBF temperature-controlled electric hot plate, also known as anti-corrosion electric hot plate, has a Teflon-coated non-stick surface and is not affected by strong acids and alkalis. It is an electric hot plate used for sample heating, digestion, evaporation, boiling and acid removal experiments.
It can be used with our Teflon series such as beakers, crucibles, digestion tubes, sample dissolving tanks, digestion tank inner cups, etc., and the effect is good.
It can meet the reagent heating needs of chemical laboratories in different industries such as physics, chemistry, biology, environmental protection, pharmaceuticals, food, beverages, teaching, and scientific research.
Technical parameters of anti-corrosion electric heating plate
Model: DBF type
Operating area (mm): 600 * 400mm, 400 * 300mm, 500 * 250mm, 450 * 350mm, etc
Heating method: Electric heating PID digital display
Working temperature: 220
Temperature control accuracy: ± 1
Surface anti-corrosion of heating plate: PFA coating
Heating plate material: exquisite aluminum alloy/graphite
Rated voltage: 220V (adjustable according to region)
Continuous working time:>48 hours
Supporting products: Crucible/beaker/PFA vials
characteristic:
1. PFA Teflon coating, anti-corrosion cast aluminum heating plate heats up quickly;
2. The board and the control box can be made into two parts, so that the acid mist during the experiment will not corrode the components in the control box, thereby increasing the service life and processing multiple samples at the same time without cross-contamination;
3. Customizable time setting function and segmented temperature control;
4. The exposed part of the power cord is wrapped with PFA tubes to further prevent acid gas from corroding components;
Advantages: Excellent Corrosion Resistance: It is coated with Teflon, a high-quality anticorrosive material, making it resistant to strong acids and alkalis. This ensures long-term stable operation of the equipment. Fast Heating Speed: The anti-corrosive cast aluminum hotplate has a rapid heating speed, which can quickly increase the temperature of the digestion solution and shorten the sample processing time. No Cross-Contamination: It allows for the simultaneous processing of multiple samples without causing cross-contamination. Reduced Metal Components: The DBF-type electric hotplate's supports are made entirely of polytetrafluoroethylene (PTFE), significantly reducing the entry of metal parts into the laboratory. Customizable Features: It offers customizable time-setting functions, segmented temperature control, and can be processed with different board surfaces according to requirements. Intuitive Display and Safety Functions: The liquid crystal display (LCD) offers features such as buzzer alarms and automatic power-off for added safety. Easy Operation and Maintenance: The anticorrosive electric hotplate has a simple structure, making it easy to operate and maintain. Energy Efficiency and Environmental Friendliness: Compared to traditional heating methods, it has higher energy utilization efficiency, reducing energy consumption and environmental pollution. In summary, the anticorrosive electric hotplate from Nanjing Binzhenghong Instrument Co., Ltd. offers superior performance in terms of corrosion resistance, heating speed, safety, and energy efficiency, making it an excellent choice for various laboratory applications.
CHEMAT TECHNOLOGY, INC. Has designed and manufactured a compact and easy-to-use hotplate, Model KW-4AH, for baking and curing thin films and coatings. Its rugged, portable design, and temperature uniformity make it a versatile tool for research facilities. In conjunction with KW-4A spin coater, KW-4AH hotplate can be used to fabricate metal oxide thin films, polymer coatings and metal organic thin films. Operation: Manual Load Process Control: Program (For details see OMRAN operation manual) Temperature fluctuation: 1C Temperature uniformity: 3% Temperature Range: ¡ª30C - 350C (KW-4AH-350) ¡ª30C - 600C (KW-4AH-600) Substrate Size: ¡ª7.5 inch X 7.5 inch(KW-4AH-350) ¡ª5.8 inch X 5.8 inch(KW-4AH-600) Inert gas purge (KW-4AH-600 only).
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 2 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: High-quality ABS plastic wrap angle. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 5 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: Metal coates high-quality ABS plastic. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, high purity alumina (HPA) combined heating plate. Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700 C. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Supplier: Crockery, Glass Products, Plastic Products
Buyer: Crockery, Glass Products, Plastic Products
The BOD (Biochemical Oxygen Demand) Incubator is a crucial medical equipment used in hospitals for environmental and medical research. This specialized incubator maintains a stable temperature, typically 20�°C, 27�°C, or 37�°C, providing an ideal environment for biological sample incubation and testing. It features precise digital controls and uniform temperature distribution to ensure accurate and reproducible results. The interior is spacious, accommodating various sample sizes and containers. With energy-efficient design and robust construction, it's reliable for long-term operation. Hospitals rely on BOD incubators for critical applications, including wastewater analysis, microbiological studies, and medical research, ensuring the highest standards of accuracy and consistency.
Laboratory Hot Plate With N ylon+GF Work Plate Material