Advantages of PFA Constant-Pressure Separating Funnel:
1.Excellent Chemical Resistance: The PFA material possesses remarkable corrosion resistance, able to withstand harsh chemicals like acids, bases, and salts without degradation.
2.High-Temperature Stability: It maintains its performance and lifespan even in extreme temperature conditions, ensuring reliable operation in high-temperature environments.
3.Accurate Control: The constant-pressure design ensures a uniform and precise flow rate, crucial for high-precision experiments and applications.
4.Ease of Cleaning: The smooth surface of PFA prevents the adherence of contaminants, making cleaning quick and effortless.
5.Excellent Sealing: The well-designed funnel boasts excellent sealing properties, minimizing the risk of volatilization and leakage of chemicals.
6.Transparency: The high transparency of PFA allows for easy observation of the liquid interface and precise control of the separation process.
7.Durability: With improved mechanical strength and wear resistance, the PFA material ensures longer service life and reduced maintenance costs.
PFA product features: 1, resistant to a variety of acids and alkalis, HF and organic solvents, and other chemical solvents; 2, high thermal stability, good transparency, smooth surface; 3, low precipitation: low metal ion dissolution and precipitation, is the storage of standard substances, corrosive, high purity reagent vessels; 4, high and low temperature resistance: use temperature -200 ~ +260 â??; no memory effect; 5, anti-pollution: low blank value of metal elements; 6, suitable for trace, ultra-trace analysis, isotope analysis, and other laboratories, is clean experimental analysis vessels; 7, in line with the laboratory or testing organizations and medical testing, trace detection and other requirements for laboratory utensils, in trace analysis and contain high-purity organic solvents (eg: high-purity water, HF, acetone, and other organic solvents, etc.);
Product Usage: Processing samples Compatible with pipette, condenser, separatory funnel It can be used in condensation reflux device and hydrogen fluoride distillation experiment Applicable industries: Isotope industry, heavy metal industry, semiconductor, new energy, new material, chemical pharmaceutical, geochemistry, geology and mineral... other products: PFA beaker, PFA reagent bottle, PFA drop bottle, PFA sample dissolution tank, PFA scrubber bottle, PFA drop bottle... FEP experimental utensils, PTFE experimental utensils, digestion apparatus, acid removal apparatus, acid purification system...
The PFA separatory funnel is mainly used in solid-liquid or liquid-liquid reaction experiments to control the amount of liquid added and the reaction rate, as well as material separation and purification, and to separate the two immiscible liquids formed after extraction. #separatoryfunnel #Solublepolytetrafluoroethylene #ICPMS #ICPOES #traceanalysis
Product Usage: add sample Separation and extraction of samples Can be used in condensing reflux devices, with condenser tubes and flasks Applicable industries: Isotope industry, heavy metal industry, semiconductor, new energy, new material, chemical pharmaceutical, nonferrous metal, precious metal... other products: PFA vessel, FEP vessel, PTFE vessel, digestion instrument, acid removal instrument, acid purification system...
It is often used in trace analysis, ultra-trace analysis, ICP-MS analysis, isotope analysis and other research industries; it can separate HF, the inner wall has no adhesion or adsorption to solvents, and can be completely drained. #ICPMS #separatoryfunnel #traceanalysis #isotopeanalysis
Jacketed glass reactor is an ideal instrument for pharmacy, biology, fine chemistry and material synthesis. With menstruum in inlayer and heating or cooling source in interlayer, jacket glass reactor can perform synthesis, distillation, separation and reflux under airproof condition. Now we can supply you jacketed glass reactor from 1-100L. Function: Putting reaction solvent into jacketed layer of glass reactor to do stirring reaction, the jacketed layer can do constant temperature, heating and cooling reaction to use cooling or heating liquid. According requirements in atmospheric pressure or negative pressure mixing reaction, and can do backflow of reaction solution with distillation. Model : TFD-50L Capacity : 50L Power: 370W Rotating Speed : 100-1400rpm Mixing Torque 1300r/min :22000g.cm Glass Kettle Cover : 60#40#/50#/29# Glass Material: Borosilicate (Pyrex: G3.3) Frame Material: Stainless Steel Mouth Amount of Vessle Lid: 4 Vaccum Degree: 0.095Mpa Machine Size(cm): 100*105*240 Can be customized as requested. Wooden cases.
Low dielectric glass fiber DW140 is made of special glass fiber, which has lower dielectric constant and dielectric loss than alkali-free glass fiber, and lower density. The thickness of electronic-grade glass fiber cloth is 0.14mm, and other varieties can also be produced: untwisted yarn, chopped strand, electronic-grade glass fiber yarn. SG Three-phase Dry Type Transformer SG-3KVA 400/20 V headlamp H7R.2 Globe Valve Seals kit 11G4DJ-1055F-14-1 MONITOR JZ-MC-V Thermo meter WTYY-1021 Modun u ra (U52) ADAM-4068 Filter element of Air filter nozzle oil pump SDSGLQ-68T-40 Level Gauge BNA15/16-MG-M900-V60-MRA-3/M/1-ZTSS200(V0.85)MG-AU-VK10-TS-M900/25(KCY-15/16-900/3/10) Low dielectric glass fiber cloth DW140 Card for controller B-A/D U13 Position Sensor of Blade MK4-A-B-800-N angular contact ball bearing 7214 BECBM Analog Signal MBD 201 Rectifier signal instruction card A55 SERVOVALVE HYDRAULIC G771K208 Lamp (Red) APS122DNR VALVE NEEDLE J23W-160P Displacement Sensor (LVDT) TDZ-1E-03 DIFFERENTIAL PRESSURE TRANSMITTE 3051CD2A22A1AI1M5D4Q4DFP9HR5 Power alarm board SDP-PR-3AY BREAKER AUXILIARY SWITCH CONTACTS FK10-II-50 PUMP DOSING S1CBH07065PVT8000UA01080EN Three-phase active power measurmnet transducer TS20-WD-3AS-165A4BN MEDIA CONVERTER EMC-02-RX SENSOR, VIBRATION VELOCITY SDJ-SG-2H Blind-free two-color water meter B69H-32/2-W bladder NXQ-AB-25-31.5-L-Y Adhesive insulation component B J793B HSNH440Q2-46NZ ELECTRO STATIC PRECIPITATOR CONTROLLER EPCS-II Liquid Leakage Detector of Generator YTG-B CELL BASAH BATTERY N 200 - 190H52 SERVO CARD DMSVC005 Oring for pump 7LDTNB-6 Flow equalize board SDP-PR-3N SENSOR MEASURING ZS04 Gaskets TN-9001 Mechanical seal for pump 65AY60 Level Transmitter ABDA6CGJ1+AAZ1 LVDT FOR HP Quick closing Valves HL-3-100-15 cam bien ap luc truoc luoi chan rac MPM426W Low dielectric glass fiber cloth DW140 DF2022-2-12-JERRY
Transparent PFA three-necked flask Constant pressure dropping funnel Condenser tube Jacketed flask Exhaust gas absorption bottle Continuous reaction filter absorption device
Glass Tube Rotameter is a Variable Area Flow Meter. A rotameter consists of a tapered tube, typically made of glass, with a 'float' made of SS or PTFE. The differential pressure across the annulus area is constant. The float moves through the tapered tube up and down with respect to fluid flow. The vertical position of the float as indicated by scale is the measure of the instantaneous flow rate. Specifications : Material of Construction : CS / SS 304 / 316 / PTFE Float : SS 316 / SS 304 / PTFE Tube : Glass Borosilicate Packing : PTFE / VITON / Silicon / Neoprene Enclosure : SS Buffed / MS Powder Coated / FRP Line Size from 15 NB to 80NB Ranges between 2.0 LPH to 2SQ00LPH ace-To-Face Distance : 500mm Accuracy : +/- 2% of Full Scale Measuring Span : 1:10 Scale : Acrylic / Aluminum / SS Various Features : Heavy Duty Design with Maximum Visibility Two Tone Powder Coated Excellent Finish No Threads in Body, Avoids Corrosion Easy to Maintain and Replace Suitable for on Line Installation Single Piece (Joint-less) PTFE/ PFA/ PP cladded end connections