Year: 2015
Tube: 2015
Tube count: 237 330 ss
Tube Model: MCT172
Collimators: Low Energy All Purpose, Low Energy High Resolution,High Energy, Medium Energy LP,
Software version console: VB10B
NexEase International exports a diverse range of Electric Goods , partnering with reputed international brands like Schneider, ABB, L&T, Siemens and more. Our selection includes Electrical Products, Electric Panels, Switchgears, Circuit breakers and Automation solutions, catering to Contractors, Facility managers Industrialists, End users and Homeowners seeking advanced energy management solutions.
'ALSTOM' Protection Relay MODEL NO:- P94VP16A7C0540A; Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .
Ref: 1415 Bulb, Spot Bulb, Decorative Bulb, RS7 Led Bulbs, Led Spots, Led 40w, 60w, 25w E14, E27, B22, GU10 Sale price: 7.5% of the PPI (public price indicated) MOQ: 1CT *40 HC / 48 pallets per CT
Gbccum21pf131a Definite Time Reverse Power Relay Relay Model Ccum21pf131a Ccum21 Aux. Current or Voltage 30v Dc C.t. Secondary 1 Amp Ct. Case Size 1-1/2d Vert. 10t Contacts (S/r or H/r) 2 N/o S/r Flag Yes Frequency 50 Hz Mounting Flush Mta Phase-char Angle 30 Degrees Time Delay P/u or D/o 0.5 - 5 Secs. V.t/p.t Secondary 110v Ac Name Plate-2 Rzf9151-601 Name Plate-1 Rfh9072-604 Outline Drawing Mfj013 Wiring Diagram Mpdz609-01-1
GBCDD21PF006SJCH DIRECTIONAL IDMT RELAY SELF POWERED RELAY MODEL CDD21PF006SJCH CDD21 APPLICATION O/C BURDEN 3VA C.T. SECONDARY 1 AMP CT. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 2 NO 1NC H/R D.M.T 3 SEC. E/F OR U/V SETTING NOT APPLICABLE FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 45 DEGREES O/C OR O/V SETTING 50 - 200% V.T/P.T SECONDARY 110V A.C(O/C) NAME PLATE-1 RFG9126-011 OUTLINE DRAWING MFJ013 WIRING DIAGRAM MPDZ801.24
ALSTOM GBCDG11AF002SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF002SACH CDG11 APPLICATION - O/C BURDEN/D.M.T - 3VA/3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5-2 Amps. Name Plate RFG9126671 Outline Diagram MFJ012 Wiring Diagram MADZ802-63-1
GBCDG11AF002SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF002SC(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5-2 Amps. Name Plate RFG9126 771 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF005SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF005SA(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.2 - 0.8 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126793 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF005SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF005SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 3 SECS. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.2 - 0.8 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126 793 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1