Shield slurry pump refers to the slurry pump used at shield construction sites. It is named after the working conditions. Just like the slurry pump used at sewage treatment sites, we generally call it sludge return pump, and residual sewage pump. Mud pumps are the same. In fact, our slurry pump is used. So what is shield tunneling? Pansto Pump Industry will first take you to understand shield tunneling construction.
The shield construction method refers to the full-section tunnel boring machine tunnel construction method. It is a tunnel construction method that relies on a rotating cutterhead to break the rock through a disc-shaped hob to form the entire tunnel section at one time.
Generally, feed pumps and discharge pumps are used at such sites. Because the shield tunnel breaks rocks at the site, the particles are generally larger. In this case, it is generally recommended to use a gravel pump with good performance, or a slurry pump with an AH series open impeller.
Because rocks are relatively abrasive, high-chromium alloys with good wear resistance are generally used as materials. The transmission mode is generally DC transmission. The sealing method is mostly sealed with packing.
If you want to know more about the shield slurry pump, please contact us!
Single-stage slurry pump, slurry pump diagram, slurry pump curve, slurry pump specifications
Slurry pump brand Warman slurry pump ZJ slurry pump ZGB slurry pump AH slurry pump
SP slurry pump vertical liquid slurry pump
Shield slurry pumps generally use our G-type gravel pumps. The particles in the slurry processed by the gravel pump have larger diameters. When selecting a gravel pump, you should ensure that the particle size requirements that the gravel pump can pass. The gravel pump can adjust the nut to adjust the impeller clearance, reduce loopholes, improve efficiency, and facilitate the disassembly and assembly of the impeller. The current-passing parts are made of high-chromium alloy, which has high hardness, high strength and longer service life than cast iron. A spare blade is used on the back of the impeller to reduce the pressure on the back, reduce the axial force, prevent some debris from entering the seal, and protect the seal from wear. Gravel pump maintenance methods. In order to reduce slurry leakage, the tightness of the packing must be adjusted at any time; the bearing water pressure and water volume must be met according to regulations. Replace bearings promptly. When replacing bearings, make sure they are clean. Ensure the temperature is appropriate during normal operation. Make sure the elastic pads in the coupling are installed correctly. Make sure the direction of rotation of the motor and pump is correct. Make sure the gravel pump assembly and piping system are installed correctly and securely. Pay attention to the degree of wear of flow parts and maintain and replace them in time. If you want to know more about slurry pumps, please feel free to call us! Shijiazhuang Pansto Pump Industry is a manufacturer of slurry pumps in Shijiazhuang. It mainly designs, manufactures and sells slurry pumps and accessories. Mainly engaged in mud pumps, submersible pumps, foam pumps, desulfurization pumps and many other series. Single-stage slurry pump, slurry pump diagram, slurry pump curve, slurry pump specifications Slurry pump brand Warman slurry pump ZJ slurry pump ZGB slurry pump AH slurry pump SP slurry pump vertical liquid slurry pump
Monoblock pumps - Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. salient features - High operating efficiency resulting in lower power consumption - Good suction lift characteristics - Inbuilt thermal overload protector in al single phase pumpsets upto 2.0 HP - Specially designed for wide voltage operation - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life - Back pull-out design for easy servicing and repair - Double shielded ball bearings, so no need of external lubrication - All Model fitted to Mechanical seal. specification - Power Range : 0.37Kw - 1.5 Kw (0.5 HP - 2.0 HP) - Version : Single Phase, 220-240V, 50Hz AC Supply Three Phase, 380-415V, 50Hz AC Supply - Speed : 2880 RPM - Maximum Total Head : 32 Mtr. - Maximum Flow Rate : 940 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Mechanical Seal - Type of Duty : S1 (Continuous) - Method of Starting : Permanent Split Capacitor (PSC) - Direction of Rotation : Three Phase, Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 25 X 25, 32 X 25, 40 X 32, 40 X 40, 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80 (All size in mm) characteristics of clear cold water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 Part Name Material Mechanical Seal : Carbon & Ceramic Motor Shaft : EN-8 Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Plastic
Monoblock Pumps Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. salient features High operating efficiency resulting in lower power consumption - Good suction lift characteristics - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. - Mechanical seal is provided as per customers requirement Specification - Power Range : 2.2 Kw - 11.2 Kw (3.0 HP - 15.0 HP) - Version : Three Phase, 380-415V, 50Hz AC Supply - Speed : 2880 RPM - Maximum Total Head : 65 Mtr. - Maximum Flow Rate : 1450 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Stuffing Box - Type of Duty : S1 (Continuous) - Direction of Rotation : Three Phase, Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80 100 X 80 and 100 X 100 (All size in mm) Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 mÃ?/sec (max.) - Ph Value : 6.5 to 8.5 Material of construction - motor Part Name Material Gland Dori : Graphite String Motor Shaft : EN-19 with SS SLEEVE Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Aluminium
Monoblock pumps Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. Salient Features High operating efficiency resulting in lower power consumption. - Good suction lift characteristics. - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. specification - Power Range : 1.5 Kw - 5.5 Kw (2.0 HP - 7.5 HP) - Version : Three Phase, 380-415V, 50Hz AC Supply - Speed : 1440 RPM - Maximum Total Head : 12 Mtr. - Maximum Flow Rate : 3160 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Stuffing Box - Type of Duty : S1 (Continuous) - Direction of Rotation : Three Phase - Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 80 X 80, 100 X 100, 125 X 125, 150 X 150 (All size in mm) Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 Part Name Material Gland Dori : Graphite String Motor Shaft : EN-19 with SS SLEEVE Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Aluminum
Suit for 50% hardenite dirty water,mud slurry; such as building operation, emergency road repair exhaust and so on; also could use as clean water pump.
Tobee TH Slurry Pump Size: 1" to 22" Capacity: 3.6-5400 m3/h Head: 6-125 m Handing solids: 0-130mm Concentration: 0%-70% Materials: Hyper chrome alloy, Rubber, Polyurethane, Ceramic, Stainless steel etc.
Slurry pumps are designed to handle liquids containing abrasive and coarse grained solids. It has a heavy duty design with a single stage axial inlet. It is also suitable for sand water mixtures and other related slurry
They are generally used for slurries containing high concentrations of erosive solids or where an Extremely heavy duty pump is required. Aojin pumps are available both metal and rubber lined corrosion and abrasion resistant materials. Discharge diameters -
We manufacture slurry pumps for various slurries in cement and concrete industry as well as other slurries across industries like pulp, clay and oil. Our slurry pumps are designed for sturdy operation with heavy duty cycles. Our pumps are precision manufactured to provide measured output or a continuous output as required. We provide two types of slurry pumps - peristaltic pumps and screw pumps, both used for positive flow of slurries. Please contact us with your requirements for further information on suitability and productivity.