Effective Lab's salt spray test chamber is used to check the corrosion resistance of our paint, powder coated and plated items. Salt Spray Test is one of the best method to check the life of painting, coating and plating. Such as powder coating, zinc plating, nickel and chrome plating, CED coating Phosphate surfaces, Alloy plating, Electroplated chromium, copper, and tin etc. Effective lab India is one of the best manufacturer of salt spray test machine instrument. Our Salt Spray chamber is specially designed according to ASTM B117, ISO 9227, JIS Z 2371, ASTM G85 standard etc. In this chamber we create salty environment with the help of compressed air and salt solution Solution ratio will be 95 parts of DM water and 5 parts of NACL (98% lab grade).
model Basic parameters DL-60 DL-90 DL-120 DL-160 DL-200 Dimensions inside the test chamber (Long �? wide �? High) 600*450*400mm 900*600*500mm 1200*1000*500mm 1600*1000* 500mm 2000*1200* 600mm Test chamber volume 108L 270L 600L 800L 1440L Volume of brine tank 15L 25L 40L 40L 40L Laboratory temperature NSS ACSS 35�±1â??ï¼?CASS 47�±1â?? Pressure barrel temperature: NSS ACSS 47�±1â??ï¼?CASS 63�±1â?? Brine temperature: 35â??�±1â?? Spray mode Ordinary type without suffix letter, economical type (M) continuous spray (A), programmable spray (B) Spray volume: 1.0ï½?2.0ml/80cm2/h(Different mist collectors need to be converted according to this ratio) Spray pressure 1.00+0.01kgf/cm2 source AC 220V 10A AC220V 10A AC220V 16A AC220V 16A AC220V 16A
Salt Spray Test Chamber | Salt Fog Test | ASTM B117 Salt Spray ChamberSalt Spray Test Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. The salt fog test chamber meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, GB/T1771, ISO9227, ASTM-B117, GB/T2423-18, QBT3826, QBT3827, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc. Specifications: A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow. Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement. The Salt Spray Chamber Working room temperature range:RT+5C~50C (The setting value cannot be lower than the current ambient temperature); Saturated barrel temperature: +40C~+63C;
1. Application Salt spray corrosion test box is designed for surface treatment of various materials, including metal plating, hardware, electronic components, chemical coatings, baking paint, automobiles, motorcycles, hardware sanitary ware, screws, springs, magnetic materials, organic and inorganic skin film, anodic treatment, rust-proof oil and other industries, testing the quality of its products and its corrosion resistance. 2. Standards Conforms to ASTM G85-02 and GB/T2423.17 test standards. 3. Performance parameters Laboratory volume: 108 L, studio size: 600 * 450 * 400 mm Laboratory temperature: 35 ~ 0 The temperature of the saturated air cylinder is 47 to 63. Maximum capacity of test fluid: 15 L External dimension: 1075 * 630 * 1185 mm Can be customized according to customer requirements.
A salt spray test chamber is used to test the anti-corrosion quality of all the materials surfaces of painting, coating, electroplating in the condition of salt spray environment. Basic salt spray test chambers meet ASTM, ISO, IEC, and other International Standards test methods, capacity available in 108L, 320L, 410L, 780L, 1000L, 1600L capacity.
Salt corrosion spray test chamber Configured for your specific tests Alternate Salt Corrosion Spray Test Chamber Grande makes rain and spray testing easier by offering a standard chamber capable of published and OEM proprietary test methods. The standardized design can be configured for the rain/spray tests you need, eliminating the guesswork in buying a chamber. The system is based on the specification requirements, and can also accomplish individual automakers tests, as well as electrical-enclosure tests. Our Design Grande's modular design allows you to add on additional features, depending on the number and type of tests required. One possible choice is to integrate the spray system with a regular temperature and humidity chamber to save money and floor space, while also creating an opportunity to simulate actual operating conditions your product may experience. Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range. The water is fed to a motorized manifold that rotates the spray arms. Each spray arm has an adjustable valve to allow finer control of the spray. Testing capabilities The specification is modeled after and doesnt differ greatly. Details about the nozzle types and the rotating nature of the spray arms and product table are also included in the requirements. Additionally, drip and car wash tests are also specified. Heavy splash/shower S1 Spray room temperature water with 40 nozzles at 14.2 psi (1 kgf/cm2) for 30 minutes. The flow rate of the water shall be 6.5 gallons/min. (24.5 L/m). S2 Spray room temperature water with 40 nozzles at 42.7 psi (3 kgf/cm2) for 60 minutes. The flow rate of the water shall be 10.3 gallons/min. (39.2 L/m). Light spray/rain R1 Spray room temperature water with two nozzles at 4.3 psi (0.3 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.8 gallons/min. (3.2 L/m). R2 Spray room temperature water with two nozzles at 1.4 psi (0.1 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.5 gallons/min. (1.9 L/m). Examples of OEM automotive manufacturers' requirements Heat the sample to a temperature above boiling, then spray with cold water for about two minutes. Repeat cycle. Heat the sample to boiling temperature, then spray with room temperature water for about fifteen minutes. Repeat cycle. Simulate a car wash by using high pressure spray. Features Rotating rain and spray nozzles designed to JIS specifications Speed control for the rotating spray nozzles Stationary product shelf - A rotating shelf is optional: see options Water pressure regulators, gauges and flow meters Special high-volume floor drain system to rapidly drain water out of the chamber Interior chamber size is the smallest possible area using the JIS specified nozzles Applicable Test Methods
2.Technical parameters: 1. Box size in the laboratory: DL-120LA W1200 * D1000 * H500 (mm), Approximate dimensions: 2300 * 1300 * 1400mm, 2 standard temperatures, Laboratory temperature: nss acss 35 ± 1 /pass 50 ± 1 Pressure bucket humidity: nss acss 47 ± 1 /pass 63 ± 1 , Salt water temperature: 35 ± 1 It can be heated without water, 3 volumes, Laboratory capacity: 800L Salt water tank capacity: 40L, 4 compressed air, Compressed air pressure: 1.00 ± 0.01kgf/c 5 spray volume: 1.0-2.0ml/80c /h, 6 spray mode: continuous spray, timed spray, programmable spray, intermittent spray, demisting in the box, 7. Power supply: AC220V 50Hz/20A, 8. Material: The entire PVC board is made, and the salt spray testing machine adopts advanced three-dimensional reinforcement technology internally, with a strong and solid structure that never deforms. 9. Water adding method: An automatic water adding system is adopted, which has the function of automatically replenishing the water level when the water level is insufficient, and the test is not interrupted. 10. Nozzle: Precision glass nozzle, salt spray testing machine used for 4000 hours to ensure no crystal blockage. 11. Protection system: Equipped with dual over temperature protection and insufficient water level warning to ensure safe use. 12. Temperature controller: digital display, PID control, high stability platinum temperature probe, error 0.3 13. Heating method: The laboratory adopts direct steam heating method, which increases the temperature quickly and shortens the standby time of the salt spray testing machine. 14. The spray tower is equipped with two conical dispersers, which have the functions of guiding fog, adjusting fog volume, and even fog falling. 15. The pressure bucket adopts Henry's law to heat and humidify, and provide the humidity required by the salt spray testing machine laboratory. 16. Opening method: Pneumatic automatic opening is adopted, The salt spray testing machine is one of the "three prevention" (humid heat, salt spray, mold) testing equipment for artificial climate environments. It is an important salt spray testing equipment for studying the adaptability and reliability of various environments in industries such as machinery, national defense, light industry, electronics, light industry electronics, and instruments. This salt spray testing machine can perform neutral salt spray tests in accordance with GB/T2423.17 "Basic Environmental Testing Regulations for Electronic and Electrical Products - Test Ka: Salt Spray Test Method", and can also perform acetate spray tests. This salt spray tester complies with CNS, ASTM, JIS and ISO standards. The salt spray test is to test the corrosion resistance of the products after coating, electroplating, Anodizing, anti-rust oil and other anti-corrosion treatments on the surfaces of various materials.
Cyclic corrosion test chamber exposes sample to a series of different environments in repetitive cycles that incorporate temperature, humidity, salt spray, and dry. SC series corrosion chambers are upgrade to programmable controller and Ethernet access.
Alternate salt corrosion spray test chamber Salt Corrosion Spray Test Chamber Salt Spray Test Chamber Configured for your specific tests Alternate salt corrosion spray test chamber adds below functions from traditional salt corrosion spray test chamber:Programmable controllers,accelerated test for copper and acid test.,etc.It complies with Standard of ASTMDIN IEC GJB. Grande makes rain and spray testing easier by offering a standard chamber capable of published and OEM proprietary test methods. The standardized design can be configured for the rain/spray tests you need, eliminating the guesswork in buying a chamber. The system is based on the specification requirements, and can also accomplish individual automakers tests, as well as electrical-enclosure tests. Our Design Grande's modular design allows you to add on additional features, depending on the number and type of tests required. One possible choice is to integrate the spray system with a regular temperature and humidity chamber to save money and floor space, while also creating an opportunity to simulate actual operating conditions your product may experience. Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range. The water is fed to a motorized manifold that rotates the spray arms. Each spray arm has an adjustable valve to allow finer control of the spray. Testing capabilities The specification is modeled after and doesn�??t differ greatly. Details about the nozzle types and the rotating nature of the spray arms and product table are also included in the requirements. Additionally, drip and car wash tests are also specified. Heavy splash/shower S1 Spray room temperature water with 40 nozzles at 14.2 psi (1 kgf/cm2) for 30 minutes. The flow rate of the water shall be 6.5 gallons/min. (24.5 L/m). S2 Spray room temperature water with 40 nozzles at 42.7 psi (3 kgf/cm2) for 60 minutes. The flow rate of the water shall be 10.3 gallons/min. (39.2 L/m). Light spray/rain R1 Spray room temperature water with two nozzles at 4.3 psi (0.3 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.8 gallons/min. (3.2 L/m). R2 Spray room temperature water with two nozzles at 1.4 psi (0.1 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.5 gallons/min. (1.9 L/m). Examples of OEM automotive manufacturers' requirements Heat the sample to a temperature above boiling, then spray with cold water for about two minutes. Repeat cycle. Heat the sample to boiling temperature, then spray with room temperature water for about fifteen minutes. Repeat cycle. Simulate a car wash by using high pressure spray.
Main Technical Parameter: Model TH-100 TH-225 TH-500 TH-800 TH-1000 Internal dimension (mm) 450*450*500 500*600*750 800*700*900 800*1000*1000 1000*1000*1000 Overall dimension (mm) 1050*880*1440 1050*1020*2000 1320*1320*2170 1470*1520*2315 1670*1520*2315 Technical structure Temperature range -20~+150 Low type : -40 :-60 : -70 Humidity range 20% ~ 98% RH Temperature fluctuations ± 0.5 Temperature deviation ± 2.0 Humidity deviation ± 2.5% RH Heating rate 3 / min Cooling rate 1 / min Control system Controller 5.7" programmable color display touch screen controller Controller optional languages are English, German, French, Russian, Spanish, Korean, Japanese. PC Link with software, R-232 interface Temperature Sensor PTR Platinum Resistance PT100O/MV A-class Temperature Resolution ± 0.001 Humidity sensor Dry and wet bulb sensor Humidity Resolution ± 1%RH Heating system Independent Nichrome electronic heating system Cooling system French TECUMSEH compressor Humidification system External isolation, stainless steel surface evaporation humidifier Dehumidification system Evaporator Water supply system Automatic water supply, Water purification system, Water saving Circulatory system Cold resistance and low noise centrifugal wind wheel Material Exterior material Steel Plate with protective coating Interior material SUS304 stainlesssteel Insulation window Double thermostability silicone rubber sealing Standardconfiguration 1 Cable hole (F 50,) cover, 2 sets of shelf, 2 protector tubes, 1 overflow water tube,1 copy of operating specification Timing Function 0.1~999.9 (S,M,H) settable Power Supply AC220V/AC380V 50HZ Three-phase five little system Ambient Temperature 5~+30 =85% RH Standard IEC60068-2-1;IEC60068-2-2;GB/T2423.1-2001; GB/T2423.2-2001