1, sensor detection
2, the basic use of the drive
3, timer instructions
4, mathematical instructions
5, high-speed counter
6, car automatic switch door control
7, elevator simulation run call indication driver
8, floor display
9, door machine torque safety protection
10, hall door security control
11, elevator terminal switch protection
12, elevator lift deceleration control
13, the use of photoelectric encoder positioning


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Transparent Elevator Training Device

Mar-31-11

Elevator Landing Door Device

$104.00
MOQ: Not Specified
 
We are a company in Shaanxi province provide all series elevator parts such as PCB, Comb plate, guide rail, guide shoe, buttom, swith, oil can, door vane, wheel etc for Fuji, Selcom, LG-OTIS, KONE, SCHINDLER, MITSUBISHI and other famous brand.
Jul-14-22

Elevator Seismic Device

$500.00
MOQ: Not Specified
Supplier From Qinhuangdao, Hebei, China
 
Accurate perception of the seismic information
Avoid earthquake damage to the elevator
Timely rescue of trapped person
Participate in the State administration of quality supervision the 2008QK21
subject research
Participate in the National elevator shockproof standards drafting


SYSTEM OVERVIEW

The elevator earthquake detector is used in conjunction with the elevator control system, make the elevator before the earthquake happened or occurs effective enter into the control operation of the equipment. Before the earthquake arrival, the elevator earthquake detector early detection to seismic waves, output alarm contacts to the elevator control system, the elevator control system according to the contacts state in the recent floor flat layer to open the door, release the passengers out of the elevator, the maximum save the life safety of the passengers, ensure that the elevator equipment is not compromised.


FEATURES AND PARAMETERS
Input voltage:AC220 10% 50 Hz 60 Hz

Output way:2 relay output

Contacts capacity:1.0 A 30 V DC, 0.5 A 125 V AC

Frequency response:0.1 Hz 30 Hz

Level 1 alarm acceleration threshold set range:0.2 m/s 1m/s

Level 2 alarm acceleration threshold set range:0.4 m/s
Acquisition accuracy:0.01m/s

Reset way:manual reset

Alarm record:100 strips

Overall Power Consumption: 1 W

Weight:1kg



SYSTEM PRINCIPLE

Product collection when the earthquake ground X/Y/Z three of the direction of ground motion acceleration, accurate detection of the earthquake happened, when P wave arrived acceleration sensor detected early earthquake of vertical vibration then output corresponding electric signals, through the filter and amplification by Analog to Digital Converter for microprocessor processed. When S wave arrival, acceleration sensors to detect the horizontal vibration, and output corresponding electric signals, through the filter and amplification by Analog to Digital Converter for microprocessor processed.

The instrument has two road relay output, respectively is level 1 alarm output, level 2 alarm output, access the elevator control system respectively, for the elevator control system collection. Level 1 alarm output is instruments detected early earthquake P wave or low vibration acceleration of earthquake movement after output, is a low-level output, used to judge may be happen earthquake, after Level 1 alarm relay action, if in 10s inside not have to achieve the Level 2 alarm ground vibration signal, the product to be automatic reset, and contacts signals disappear. Level 2 alarm output corresponding higher ground motion of the output of the acceleration, can't automatic reset, and need professional elevator operator to inspection elevator, and after confirm the elevator without any fault then manually reset.


FUNCTION CHARACTERISTICS
Jul-14-23
 
1, let students familiar with the industrial commonly used sidewalk escalators working principle, structure composition, low-voltage electrical structure and principles.
2, through the analysis of electrical schematics, students with the help of schematic analysis, master the safety protection and working form of elevators, and through analysis and measurement, to find out the location of fault points, a deep understanding of the operation of elevators.
3, improve the actual hands-on analysis ability of students, and actually improve the level of skill operation.
4, through the analysis and elimination of elevator faults, to complete the common elevator fault cognition and understanding.
5, through the PLC host programming, understand the PLC program programming principles and methods. 6, escalator safety operation and use of practical training
7, rung disassembly operation and practical training
8, comb plate adjustment and practical training
9, armrest belt tension adjustment and practical training
10, rung chain tension adjustment and practical training
11, brake adjustment and practical training
12, maintenance before the safety knowledge operation and practical training
Daily maintenance
13, escalator emergency rescue
14, escalator safety circuit fault finding and troubleshooting practical training
15, escalator access circuit fault finding and troubleshooting training
16, escalator safety monitoring circuit fault finding and troubleshooting training
17, escalator power circuit fault finding and troubleshooting practical training
18, escalator control circuit fault finding and troubleshooting training
Jul-14-23
 
1, to understand the structure of escalators, tightening device, rungs, ladder rails, armrest straps, traction chain, comb plate, drive device and other major components name and role.
2, to understand the role of escalator installation protection device, installation position includes: traction chain break protection device, armrest belt entrance safety protection device, ladder subsidence protection device, drive chain break protection device, armrest belt break protection device, brake, mechanical locking device.
3, the basic safety operation and use of escalators;
4, rung disassembly operation;
5, comb plate adjustment;
6, comb cutting-edge plate adjustment;
7, armrest tight adjustment;
8, the adjustment of rung chain tension;
9, the adjustment of the drive chain;
10, escalator anti-reversal mechanical experiments;
11, upper and lower traction chain safety experiments
12, host chain-breaking safety experiments
Nov-16-04

Bbe Automation Erd

$800.00
MOQ: Not Specified
Supplier From Beirut, Lebanon
 
Emergency rescue device for elevators
In case of power failure the device drives the car to the nearest stop taking into consideration the load inside the car the device can switch dirve frequency in order to avoid overload it can also detect the current to switch directions, and to save battery energy
Equiped with dry maintenance free batteries and a switching mode power supply charger.

60x80x20
Nov-16-04
Supplier From Beirut, Lebanon
 
BBE M517 CPU CONTROLLER
Up to 32 floors in octoplex operation capability,
Built in magnetek's elevator ac drive for super comfort ride at all speeds, Access Code VIP floors Programming, advanced statistics and troubleshooting


5.5kw 100x80x25
Dec-11-08

Elevator Roller

$3.20 - $5.50
MOQ: Not Specified
 
Elevator roller
Dec-11-08

Plastic Rollers

$3.20 - $5.50
MOQ: Not Specified
 
Plastic rollers
Mar-22-24
Supplier From Chongqing, China

Verification Status