Model: XJ type
Number of holes: 16, 20, 24, 36, 40, 42, 48 bits, can be customized
Heating method: three-dimensional wrapping heating PID temperature control digital display
Temperature control range: room temperature -220
Temperature control accuracy: 1
Uniformity between holes: temperature difference between holes 1.5
Panel surface temperature difference: The temperature difference of the same panel surface (middle and corner) does not exceed 3-5, which effectively ensures the uniformity of the sample and the experimental efficiency is high
Temperature fluctuation: 0.5
Anticorrosion on the surface of the heating plate: imported Teflon coating
Heating plate material: high quality fine graphite
Rated voltage: 220V
Heating power: 2-3KW
Continuous working time: 48h
Ancillary products: all kinds of digestion tubes
Features:
1. Split type, the controller can be placed outside the fume hood and separated from the digestion unit to avoid corrosion of electronic components.
2. The closed design can effectively prevent the loss of heat and avoid the invasion of acid mist
3. Warranty: 1 year
Graphite digestion instrument is a heating device specially designed and manufactured for laboratory heating, which can be used for sample heating, cultivation and drying. It adopts international advanced technology and has the advantages of fast, efficient, energy-saving and convenient acid flushing. It uses digital circuit PID to control temperature, which is more accurate. High purity and high quality graphite heating carrier, coated with Teflon coating, has been successfully used for sample pretreatment in environmental protection, chemical industry, food, medicine, biochemistry and other industries. It can also be used for pretreatment of microwave digestion and acid rush treatment. It is an ideal supporting product for atomic absorption, atomic fluorescence, ICP-AES and other analytical instruments. characteristic 1. Design: generous appearance: simple, upright and generous. 2. Clean and corrosion resistant: the heating body is coated with extra thick PFA, which is corrosion resistant and pollution-free. The unique spraying process is adopted, and the coating is uniform, firm, and will not fall off after long-term use. 3. High efficiency: advanced all-in-one surrounding heating mode is adopted, so that each part of the sample is heated evenly, which greatly prevents heat loss, eliminates the temperature difference between different parts of the same sample, and quickly and thoroughly dries acid. 4. Economical: The surrounding heating process is fast and convenient, which can save 75% of electric energy and has low use cost. 5. Precise temperature control: PID temperature control system, simple and convenient operation, excellent performance, durable. The temperature control accuracy is high, up to and the heating rate is stable. 6. Superior thermal conductivity: a reasonable heating method and a heating body with excellent thermal conductivity can ensure the temperature uniformity between digestion holes. The temperature difference between samples is less than 1.5 (room temperature - 260 ). When several samples are acid treated at the same time, the same reaction temperature and conditions can be guaranteed for each sample for batch processing.
Graphite digestion instrument is one of the direct, effective and economical sample pretreatment methods for elemental analysis. The application of new heating technology has the advantages of rapid heating, program control, complete digestion, and temperature equilibrium. Our devices are usually used in sample preparation for atomic absorption, atomic fluorescence, ICP, ICP-MS, polarography, etc. 7 advantages make sample preparation no longer difficult: 1. The fully enclosed design prevents heat loss to a large extent and effectively avoids the intrusion of acid mist; 2. High-quality graphite three-dimensional wrapped heating, samples are heated evenly; 3. Unique spraying process, the coating is uniform, firm, and will not fall off after long-term use; 4. Fast digestion and acid removal, high efficiency, and batch processing of samples; 5. PID digital temperature control system, excellent performance; 6. Easy operation, environmental protection and energy saving, cost saving 7. Split type: The controller can be placed outside the fume hood to reduce acid gas corrosion and have a longer service life.
Product Usage: It is mainly applicable to food, disease control, academy of agricultural sciences, medicine, agriculture, forestry, environmental protection, chemical industry, biochemical and other industries, as well as universities and scientific research departments for soil, blood samples, urine samples, nails, food, dairy products, agricultural and sideline products, Sample digestion before chemical analysis of feed, heavy metals, ores, etc. It can be used in conjunction with analytical instruments such as atomic absorption, atomic fluorescence, ICP-AES and Nanjing Binzhenghong heavy metal electrothermal digestion instrument other products: PFA beaker, PFA reagent bottle, PFA drop bottle, PFA sample dissolution tank, PFA scrubber bottle, PFA drop bottle... FEP experimental utensils, PTFE experimental utensils, digestion apparatus, acid removal apparatus, acid purification system...
1. Wet digestion treatment plan for lithium batteries: determination of nickel cobalt lithium material (determination of nickel, cobalt, and manganese content in nickel cobalt manganese oxide lithium material for lithium-ion batteries) 2. Determination of matrix metal impurities in electronic grade polycrystalline silicon: iron, chromium, nickel, copper, zinc, sodium. Wet digestion treatment scheme for lithium batteries - determination of iron content A combination of graphite digestion instrument or aluminum alloy anti-corrosion electric heating plate+PFA or PTFE beaker can be used for digestion After digestion, transfer to a PFA or FEP volumetric flask for constant volume, dilute with water, and finally use analytical instruments such as ICP-MS to measure elemental data
Graphite digestion instrument wet digestion to process the sample, adds acid to the sample, and accelerates the chemical reaction through heating to convert the test components into a liquid state, which is then further analyzed by elemental analysis instruments. For example , in the analysis of ores, soil, food, etc., it is often necessary to use a graphite digester to digest organic matter samples into a liquid state for further analysis. #digestioninstrument #samplepreparation #ICPMS
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
3ply face mask comfortable for user. The face mask is latex free and use brand new hypoallergenic material, odourless and lint free. Product Disposable 3-Ply Non-Woven Face Mask with Ear Loop Size 18cm x 9.5cm (18cm after expended) Color Blue/Green/White/Yellow/Pink or can be customized Outer Layer Spund-bound PP Nonwoven: 20 - 25 gsm Filter Medium Meltblown PP Nonwoven: 18 - 20gsm Inner Layer Lint free ES Nonwoven: 25 gsm Nose Piece Aluminum Packaging 50 pieces per box or 50pcs per bag; 10 boxes/bags per carton. 1600 cartons/20 ft container , 3200 carton/40 HQ container. MOQ 50,000 pieces min order Quantity: 10,000PCS/Day MOQ : 10,000 pieces Packaging: 50 pieces per box/bag; 40 boxes per carton. Payment condition: TT Shipping Duration: 7 Days ( ONE WEEK) Origin: Thailand/China Condition: Subject to availability