Includes:
- Olympus NORTEC 600D Dual Frequency
- Calibration certificate
- Charger/adaptor
- AC power cord
- Getting Started leaflet
- NORTEC 600D Users Manual and PC interface program on CD-ROM
- Universal PowerLink eddy current probe cable
- MicroSD memory card, 2 GB (1 internal, 1 external)
- USB 2.0 (mini-AB) to PC cable
- 67 watt-hour battery for 600 Series products, 10.8 V, 6.2 Ah, 67 Wh
- AA battery holder for emergency use
- Factory-installed hand strap on left side of NORTEC 600D instrument
- Instrument transport case
- Olympus NEC-8196L Weld Inspection Kit
Specifications PRF 10 Hz to 2000 Hz in 10 Hz increments Pulse Width Adjustable from 25 ns to 5,000 ns (0.1 MHz) with PerfectSquare technology Gain 0 to 110 dB Receiver Bandwidth 0.2 MHz to 26.5 MHz at â??3 dB System Linearity Horizontal: �± 0.5% FSW Resolution 0.25% FSH, amplifier accuracy �± 1dB Reject 0 to 80% FSH with Visual Warning Amplitude Measurement 0 to 110% full screen height with 0.25% resolution Automated Calibration Velocity, Zero Offset Straight Beam (First Backwall or Echo-to-Echo) Angle Beam (Soundpath or Depth) Test Modes Pulse Echo, Dual, or Through Transmission Range 3.36 mm to 13,388 mm (0.132 in. to 527.10 in.) at 5,900 m/s (0.2320 in./�µs) Velocity 635 m/s to 15240 m/s (0.0250 in./�µs to 0.6000 in./�µs) Zero Offset 0 to 750 �µs Refracted Angle 0�° to 90�° in 0.1�° increments Measurement Gates 2 fully independent gates for amplitude and TOF measurements Measurements Gate (1, 2) Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight, Min./Max. Depth, Min./Max. Amplitude Echo-to-Echo Standard Gate 2-Gate 1, Optional IF Gate Tracking Other measurements Overshoot (dB) value for DGS/AVG, ERS (equivalent reflector size) for DGS/AVG, AWS D1.1/D1.5 A, B, C and D values, Reject Value, Echo to RefdB values DAC/TCG Standard DAC points Up to 50 points, 110 dB dynamic range Special DAC modes Custom DAC (up to 6 curves), 20-80% View Curved surface correction Standard OD or Bar correction for Angle Beam measurements
Sale Olympus CF-H190I Colonoscope Condition: Used Year :2018 Come with warranty 12 month Features: - Delivers highest possible resolution and image quality - Olympus-exclusive variable stiffness capability - Auxilary water jet facilitates mucosal clensing - Ergonomically designed grip to enhance scope maneuverability and handling - Scope ID function stores individual scope information such as number of procedures performed - The benefit of Narrow Band Imaging (NBI) to enhance visualization of mucosal morphology - Must be used with Exera III CV-190 processor and CLV-190 light source - 170 Wide-Angle - Responisive Insertion Technology Specifications: Optical system: - Field of view: 170 - Direction of view: Forward viewing - Depth of field: 2 100 Insertion section: - Distal end outer diameter: 13.2 mm - Insertion tube outer diameter: 12.8 mm - Working length: L: 1680 mm I: 1330 mm Instrument channel: - Channel inner diameter: 3.7 mm - Minimum visible distance: 3.0 mm from the distal end - Direction from which endotherapy accessories - enter and exit the endoscopic image Bending section: