EBS Modulator 4801020640
To facilitate the clients, further we are offer authentic range of impact & environmental recorders that is used for recording varied environment conditions during transportation, storage as well operation. These recorders are assembled and incorporated with latest gps / gprs tracking module required to record any kind of impact and generate reports so as to decrease the rate of products damaging. The various environmental factors like humidity, temperature changes, till and atmospheric pressure can be recorded in this devise and can be rectified to reduce the damaging of the products. They are capable of recording shock, vibration or any environment related impact conditions and can exactly record the time duration of the mishandling. These devices are incorporated with advance triaxial piezoelectric accelerometer technology is used for recording the exact amplitude and direction of impact that enables to set certain control measures to prevent the products from damaging further.
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
EBS Modulator ES2095
Description The Trusted TMR 24V dc digital input module interfaces to 40 field input devices. A wide input voltage range and programmable thresholds allow the module to be used in current source and current sink configurations. Comprehensive diagnostic tests are performed on each input channel, including tests for stuck on and stuck off failures. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 input channels. When a line-monitoring device is installed at the field switch, the module can detect open and shorted field cables. Line monitoring can be independently configured for each input channel. The module provides on-board sequence of events (SOE) reporting with a resolution of 1ms. A change of state triggers an SOE entry. States are determined by programmable voltage thresholds that can be configured on a per channel basis. When the field voltage and field return are connected to the auxiliary input channels of the module, thresholds can be specified as a ratio of the current field supply voltage. Each triplicated section of the module, referred to as a slice, conditions and measures each channel independently. Each slice is optically isolated up to 2500V dc. Each slice sends its data to a safety layer hardware voter that presents the information from all three slices to the Trusted TMR processor. When a fault is detected on a slice of the module, the Trusted TMR processor will flag the error, indicating the need to replace the module. The Trusted TMR processor will continue to use the information provided by the remaining two slices until a replacement module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly. Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot. Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor. Features 40 TMR input channels per module. Comprehensive diagnostics and self-test. Line monitoring on a per channel basis. 2500V dc optically isolation. On-board 1ms resolution sequence of events reporting. Hot replaceable. Front panel status LEDs for each channel. Module fault and status indicators. IEC 61508, SIL 3 safety applications.
6 sets of abb asynchronous motor, 2100kw, 6600v, 212a, 60hz, pf=0.91, 3578rpm. Manufactured in 1996 but never used and store in warehouse from a cancelled ccpp project. Available with 6 sets of complete fuel(lng) gas compressor modules.
Description The Trusted TMR analogue input module interfaces to 40 single-ended field input devices. A wide input range and programmable thresholds allow the module to be used in most voltage or current configurations. Comprehensive diagnostic tests are performed on each input channel, including tests for out of range values and stuck at failures. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 input channels. The module can apply a digital filter to each input channel. Individual channels can be configured for high noise immunity (50Hz or 60Hz rejection), low noise immunity (fast response) or pass-through operation (no filtering). Each input channel has four configurable state thresholds, which may be assigned to SOE reporting. A change of state triggers an SOE entry. The on-board sequence of events (SOE) reporting has a resolution of 1ms. Each triplicated section of the module, referred to as a slice, conditions and measures each channel independently. Each slice is optically isolated up to 2500V dc. Each slice sends its data to a safety layer hardware voter that presents the information from all three slices to the Trusted TMR processor. When a fault is detected on a slice of the module, the Trusted TMR processor will flag the error, indicating the need to replace the module. The Trusted TMR processor will continue to use the information provided by the remaining two slices until a replacement module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly. Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot. Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor. Features 40 TMR input channels per module. Comprehensive diagnostics and self-test. 2500V dc optically isolation. Digital signal filtering on a per channel basis. Four user configurable thresholds per channel. On-board 1ms resolution sequence of events reporting. Hot replaceable. Front panel status LEDs for each channel. Module fault and status indicators. IEC 61508, SIL 3 safety applications.
Description The Trusted TMR 24V dc digital output module interfaces to 40 field output devices. Outputs are arranged in five groups of eight outputs. All outputs in a group share a common power source and return. Fault tolerance is achieved through Triple Modular Redundancy (TMR) within the same module for each of the 40 output channels. The module provides on-board sequence of events (SOE) reporting with a resolution of 1ms. The event is the actual sensing of the field device loop current. Each triplicated section (slice) of the module, receives output data from the Trusted TMR processor and sends its data to an internal safety layer hardware voter. Each slice uses the voted data to control the outputs. Every output channel consists of a six-element voted array. The output switch array provides fault tolerant, uninterrupted control under an output switch failure condition. Output switching and fault diagnostics comply with the demanding requirements of IEC-61508 SIL-3 for First fault - Fault tolerant, and Second fault Fail-safe outputs. When a module fault is detected, the Trusted TMR processor will flag the unhealthy condition, indicating the need to replace the module. Control continues until a replacement (healthy) module is available. Replacement modules can be located in a standby slot next to the module or in a designated SmartSlot with a temporary connection to the same Trusted termination assembly. Each output is user configurable to perform line monitoring of the connected field devices to detect field wiring and load failures. Automatic over-current protection is inherent in every output circuit which eliminates the need for fuses. Modules may be placed in any I/O module slot in a Trusted processor chassis or expander chassis. Once the I/O module configuration is set, mechanical keying is available on all I/O modules to prevent inserting a module into an incorrect slot. Configuration of the module is carried out using the Trusted Toolset running on an engineering workstation. Once configured and loaded into the Trusted controller, replacement modules are online educated by the TMR processor. Features 40 TMR output channels per module. Five isolated groups of eight outputs each. Six-element voted output array. Comprehensive diagnostics and self-test. Guaranteed, First fault fault tolerant, Second fault fail-safe. Line monitoring on a per channel basis. Automatic over-current protection no fuses required. 2500V dc optically isolation. Hot replaceable. Front panel status LEDs for each channel. Module fault and status indicators. IEC 61508, SIL 3 safety applications. On-board 1 ms resolution sequence of events reporting.
4-20mA analog output for direct communication to DCS system or RS485 ModBus RTU output optiona. Relay output for connecting external device LCD display screen(LED display screen optional) Advantage: Sensor module(block) design on -spot replacement s and automatically distinguish sensor fault and current display fault simultaneously. When the sensor out of service or the sensor fails, the user can check and solve the problem by replacing spare modules,saving the time and cost. The LCD display and LED display module can be interchanged, supporting swift hot swap,support plug and play functionality. The sensor module and the connection interface in the detector have jack and plug prevent improper insertion.Just spin and press the plug gently,the plug can be inserted the jack. The sensor module of the detector can be replaced by the same type module and the different gas sensor module,and different range sensor module. The detector can distinguish and operation itself. Whatever the sensor module is chosen to replace the original one, there is no need to re-calibrate it. The detector automatically distinguishes the sensor module, reads the ex-factory calibration value and the related setting value and operates detecting when the self-inspection is done. Password verification for repeat operation, avoid fault operations. -40~+70 following compensation for accurate detecting. Twp grade visual alarms on-site and Relay (connected with audible/visual alarms or drive exhaust device). User-selectable alarm setpoint(s).