Circuit breaker refers to the switching device that can close, carry and disconnect the current under normal circuit conditions, and can close, carry and disconnect the current under abnormal circuit conditions within a specified time. Circuit breakers are divided into high-voltage circuit breakers and low-voltage circuit breakers according to their scope of use. The division of high-voltage and low-voltage boundaries is relatively vague. Generally, those above 3KV are called high-voltage appliances.
The circuit breaker can be used to distribute electric energy, start the asynchronous motor infrequently, and protect the power line and motor. When they have serious overload, short circuit, undervoltage and other faults, it can automatically cut off the circuit. Its function is equivalent to the combination of fuse switch and over and under heating relay. Moreover, it is generally not necessary to change the parts after breaking the fault current. At present, it has been widely used.
Power distribution is an extremely important link in the generation, transmission and use of electricity. The distribution system includes transformers and various high and low voltage electrical equipment, and the low voltage circuit breaker is an electrical appliance with large amount and wide range of use.
working principle
The circuit breaker is generally composed of contact system, arc extinguishing system, operating mechanism, release, shell, etc.
In case of short circuit, the magnetic field generated by large current (generally 10 to 12 times) overcomes the reaction spring, the release pulls the operating mechanism to act, and the switch trips instantaneously. In case of overload, the current increases, the calorific value intensifies, and the bimetallic sheet deforms to a certain extent to promote the action of the mechanism (the greater the current, the shorter the action time).
Supplier: Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment.
Services: We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
Buyer: Industrial electrical parts
Type Universal USB charger socket Charging Port 2 Ports Connection Universal USB charger socket Warranty 1 Year Combination Charger Socket Outlet Voltage 12-24v Model Number DS2014 Design Style New China-Chic Product name 4.2A Car Cigarette Lighter Socket Splitter Dual USB Charger Material ABS Input Voltage 12V-24V USB output 4.2A Size 3.7*5.4*2.9cm/1.5*2.12*1.14inch LED Blue LED Waterproof grade IP65 Working temperature Min.-20 Celsius Degree, Max. 80 Celsius Degree
VN1-40.5E medium-voltage AC vacuum circuit breaker is a new product designed by our company. The main circuit is with the solid insulated structure and uses the advanced epoxy resin sealed technology. Firstly it assembles a integrated sealed pole column with the vacuum interrupter, the main circuit, the insulated support and so on, which enhances the environment endurance of the vacuum circuit breaker. 1. The main circuit section and operating mechanism section is upper and lower arrangement, which optimize the electric field distribution, increase the insulated reliability, also reduce the circuit breaker depth direction size and reduce the matched switchgear depth greatly. 2. The live part of main circuit is cast in the epoxy resin cylinder, which make the interrupter be exempt from the environmental effect and the external mechanical force injury, also cause the circuit breaker no arc-over between phases and on the interrupter's surface and enhance the insulation of circuit breaker. 3.Current carries are fixed reliably in the position by the epoxy resin, do not need the extra fastener, reduce the number of accessories used for assembling circuit breaker pole columns, reduce the installation error and enhance the reliability of installing the circuit breaker. 4. As a result of using the sealed technology, the circuit breaker volume reduces greatly. The matched cabinet width is only 1200mm, heighten 2400mm, depth 2600mm. 5. The VN1 circuit breaker is based on the self-supporting structure of bottom plate, has overcome the primary contacts linking due to the circuit breaker submersion and also transport conveniently.
The Variable Speed Drive FRENIC series is equipped with functions and performance to meet all types of requirements, and in addition it is easily maintained and environmentally friendly. The series lineup ranges from simple to advanced-function models, enabling model choices matching situations for use. Fuji Electric provide Variable Speed Drives perfect for automating and with energy saving devices like a fan pump or carrier and variable speeds.
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Product Description Residual current circuit breaker RCCB Rated current: 25A, 32A, 40A,50A,63A,80A,100A Rated sensitivity: 10mA, 30mA, 100mA,300mA Product Feature Feature (EBS6R Residual current circuit breaker ) 1. Electro-magnetic release, voltage independent 2. High ability of withstanding short circuit current Connection ( EBS6R RCCB ) Type of terminal: Lug type and pin type Cables up to 35mm2 Product Specification/Models Model: EBS6R RCCB ( Residual current circuit breaker ) Standard: IEC61008-1 Rated current In (A): 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A Rated voltage Ue (V): 2 poles: 230VAC 4 poles: 230/400VAC Poles: 2P, 4P Standard export carton
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".