Conventional Optic Smoke Detector With Relay Output Function is a safety fire detection. It can be link with alarm system to prevent fire.
Features:
1. Strong adaptability for circumstance
2. SMT Design, High stability
3. 9-35V DC Wide voltage operating range
4. Low standby currency
5. Power supply non-polarized input
6. Twin LED for 360�° visual
7. Flashing LED power indicator
8. Remote LED indicator output
9. Metal shield, anti-electromagnetic interference
48V smoke detector with relay output is a fire safety detector device. It is widely used for Telecom or Mobile's machine room or computer room of factory or electric power. When it detects smoke, the detector sent a relay signal to fire alarm system to remind with LED lit on. Features: 4 wire interconnection 48V DC powered Frosting plastic High sensitivity To Set NC or NO Description: Working voltage: DC48V Static current:
DC 48V Wired Smoke Detector With Relay Output For Electrical Base Station. 48V Wired Smoke detector is a fire safety device to detect smoke, and prevent fire. When it detects smoke, the detector sent a relay signal to fire alarm system to remind with LED lit on. Specification: 1. Power: DC 48V 2. Static current::
DC 48V Smoke Detector With Relay Output is a safety device to detect smoke, and prevent fire. When it detects smoke, the detector sent a relay signal to fire alarm system to remind with LED lit on. It used for Telecom or Mobile's machine room or computer room of factory or electric power. Features: * 4 wire interconnection * 48V DC powered * Frosting plastic * High sensitivity * To Set NC or NO Description: * Working voltage: DC48V * Static current::
Type Cigarette Lighter Charging Port 2 Ports Connection Wired Warranty 1 Year Place of Origin GUA Combination Charging Voltage 12-24v Brand Name Yujie Model Number DS2013 Design Style New China-Chic USB Output Voltage 5V Color Black USB Output Current 3.1A(2.1A+1A) Material Engineering plastics + electronic components Size 36.5x52.5mm (Diameterx Length) Light Indicator Blue LED USB Socket Size 2.05"x1.35" Install Hole Size 1 1/8" Terminals 6.35mm Certificate CE ROHS FCC Packaging Details Polybag Selling Units: Single item Single package size: 3X3X4 cm Single gross weight: 0.050 kg
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
The main features: A switching capability. Optional contact arrangement. Plug-in or pc board terminals. Extended operation range. Optional mounting bracket. The typical applications: Rear window defogger, battery disconnection, air-conditioning, fuel pump control, cooling fan (multi-speed), fog lamp & headlight control.
EOCR-SS 2 integral Current Transformers Electronic Shear-pin Functions Independently Adjustable Starting Trip Delay (D-Time) & Operating Time (O-TIME) Features: Compact Design Multiple Protection Functions Wide Current Adjustment Range (10:1) Ammeter Function Trip Indication LED High Accuracy Manual Instantaneous Reset Electrical Remote Reset Test Function Ambient Insensitive Low Energy Consumption Fail-safe Operation (No Volt Release) Protection: Protective Item operating (trip) Time Over-current O-Time Phase Loss O-Time Locked Rotor O-Time+D-Time .
Solid state relay Input Ac 3~32,Ac220,Dc 3~32v Output Ac 200~270 v Load 10 A, 16A, 25A, 40A 12 pcs,120 pcs