Please click here to check who's online and chat with them.

Jsdxc2-1700 Dynamic Relay

Supplier From China
Nov-11-21

3. When repairing or replacing the relay, first remove the national relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket.



Faults and troubleshooting methods

1. The relay contact has no output

The analysis and elimination methods of the relay contact without output are as follows:

(1) Make sure that the relay and socket should be reliably plugged in;

(2) Check that the relay should not be mechanically blocked. If foreign matter in the relay blocks the armature, the armature cannot work reliably (forward rotation) or release (reverse rotation), and the contacts cannot be reliably contacted;

(3) Check that there should be no foreign matter between the contacts, there is foreign matter between the contacts, and the contacts cannot be reliably contacted;

(4) Check that the contact resistance of the relay contact should not be too large.

2. The relay does not work or the relay with a pole cannot be reversed in the forward direction
be reliably released.


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Jsdxc2-1700 Dynamic Relay

Oct-05-21
 
Product Features

JWXC-1700 type infinite relay (hereinafter referred to as relay) is used as a general relay in the signal circuit.



Features

1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.

2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.

3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay.

4. The contact system is composed of ordinary contacts, with eight groups of common contacts for switching on and off.

5. The rated voltage of the relay is DC 24V.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25â??);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: vibration is not more than 15Hz, amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 8QH;

Identification pin number: 11, 51;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.



Electrical characteristics (at 20c)

Coil resistance: 850 (1±10%) 2

The coils are connected in series, connect 2, 3, use 1, 4;

Rated value: DC24V;

Magnetizing value: DC67V;

Working value: not more than DC16.8V;

Release value: not less than DC3.4V;

Reverse working value: not more than DC18.4V;

Contact resistance: not more than 0.05.



Insulation withstand voltage

Under the standard atmospheric conditions of the test, the absolute resistance of the relay should not be less than 100MQ.

Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz,

2000V rms voltage, there should be no breakdown flashover after 1 min, and the voltage during repeated test should be 75% of the original test voltage.



Product electrical life

The relay contacts are connected to DC24V1A resistive load; its electrical life is 2106 times.
Nov-11-21
 
Product Features

JSDPC-1000 dynamic relay, JSDPC-820 dynamic relay, and JSDPC-830 dynamic relay were once used in microcomputer interlock interface circuit.

At present, JSDPC-1000 dynamic relays, JSDPC-820 dynamic relays, and JSDPC-830 dynamic relays have ceased to be used on large railways, and are only used in hump circuits when users require them.



Features

1. Two-way dynamic control signal relay.

2. Controlled by dynamic pulse signal.

3. Dynamic pulse control signal:

JSDPC-1000 dynamic relay is 24V, 2.5Hz.

JSDPC-820 dynamic relay is 24V, 1Hz.

JSDPC-830 dynamic relay is 24V, 5Hz.
Nov-11-21
 
Product Introduction

JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit.



Applicable environment

a) Ambient temperature: -40~+60;
Nov-11-21
 
Product Usage

The JWJXC-7200 type stepless enhanced contact relay is used as a power supply supervisory relay for the electric point machine in the power supply screen of a large station.



Product function

JWJXC-7200 type stepless enhanced contact relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



product structure

The electromagnetic system of the stepless strengthened contact relay is a stepless magnetic circuit with an enlarged size. The contact system is composed of two parts: a normal contact and a strong contact. The normal contact is the same as the stepless relay. Switches, switch start, etc.) designed contacts and isolator.



Mechanical properties

Number of contact groups: 4QJ; 2H

Identification pin number: 14, 55;

Strengthen the contact gap: not less than 7mm;

Ordinary contact gap: not less than 4.5mm;

Reinforce the gap of the support plate: generally not less than 0.35mm;

Reinforce the gap of the support: the reinforcement is not less than 0.1-0.3mm;
Nov-11-21
 
Product Usage

The JWJXC2-6800 type enhanced contact relay is used in the distributed power supply screen.



Product function

It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



test method

Standard test conditions

Temperature: +15â??~+45â??;

Relative humidity: 45%~75%

Air pressure: 86kPa~106kPa

Requirements for testing measuring tools, meters, and power supply

The accuracy of the measuring tool for measuring appearance and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%.

The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1.

The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz.



Mechanical properties
Nov-11-21
 
Product Usage

The JYJXC-135/220 type has a pole reinforced contact relay used as a switch control relay in a signal circuit.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Mechanical properties

Number of contact groups: 2DF, 2DFJ;

Identification pin number: 15, 54;

Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm;

Pallet gap: ordinary contact point is not less than 0.35mm;

Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN;

Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN;

Contact uniformity error: between ordinary contacts and ordinary contacts, between ordinary contacts and reinforced contacts, no more than 0.2mm, between reinforced contacts and reinforced contacts, no more than 0.1mm.

Positioning or reverse position holding force is not less than 4N;
Nov-11-21
 
product description

JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25);

c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



product structure

Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.
Nov-11-21
 
Product Introduction

The JWJXC-160 type stepless enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the switch and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product Usage

The JWJXC-160 type stepless strengthened contact relay is used as a phase-failure supervision relay in the power supply screen.



Applicable environment

a) Ambient temperature: -40~+60;

b) Relative humidity: not more than 90% (temperature +25C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Nov-11-21
 
Product Introduction

The JWJXC-135/135 stepless enhanced relay is an important element in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.



Product function

It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.



Product Usage

JWJXC-135/135. Infinitely enhanced relays (hereinafter referred to as relays) are used as general relays in signal circuits.



Applicable environment

The applicable environment of the relay is:

a) Ambient temperature: -40â??~+60â??;

b) Relative humidity: not more than 90% (temperature +25�°C);

c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

e) Working position: horizontal;

f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.



Insulation withstand voltage

Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.

Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.

Verification Status