Warranty:
3 years
Classification:
Other
Certification:
CE, ISO
Customized support:
OEM
Brand Name:
oem
Model Number:
D81250
Place of Origin:
China
Material:
Plastic
Color:
Blue
Application:
Lab Consumables
Certificate:
CE ISO
Usage:
Lab Application
Packing:
Individual Pack
Advantage:
Trade Assurance
Specification:
Customer`s Request
Sample:
Accepted
Product name:
Cell Scraper
Plastic pipette fills the fragile defect of glass tube and ends the history of glass tubes and rubber plug for the transfer of high-risk contagiousness liquids. The interior of the pipette is smooth and reduces the damage to the tissue structure and cell in the liquid. It can transfer the liquid sample safely, rapidly and quantitatively. It is resistant to low temperature and can be sterilized at high temperature.
Pre-filled Normal Saline Flush Syringe Refer Standards ISO 7886-1:2017 Sterile hypodermic syringes for single use - Part 1: Syringes for manual use. ISO 80369-7:2016 Small -bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications. USP Bacterial Endotoxins Test. USP Particulate Matter in Injections. USP PH. USP Sterility Tests. USP Heavy Metals USP Plastic Packaging Systems and Their Materials of Construction. ISO 10993-18: 2020 Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process.
According to ISO require to sterilization indicator instruments, our sterilization indicator card formulate class 1-calss 6.The plastic film on the appearance of indicator card which belong to Class 6, it is high safety.
Hydrogen Peroxide Sterilizer, Hydrogen Peroxide Fogging system Type: SV-06, SV-08 Design for room sterilization. SV series Hydrogen peroxide sterilizer applies low concentration hydrogen peroxide fogging combined with high frequency and high pressure ionizarion technology to carry on room sterilization. Hydrogen peroxide produces free OH- during the process, which causes oxidative damage to cell components, thus achieving the purpose of eliminating bacteria. This instrument specially designed for sterilization in enclosed spaces such as hospital, isolation room and clean rooms. There is also coming new types for isolator, transfer cabinet, blending machine,small clean room, split butterfly valve, etc. It can be used to conduct online sterilization of RABS on filling line as well.
Sterility Test System Compliance with regulatory requirements in ChP, USP, EP and JP. SM86 sterility test system is used for sterility test in sterile product.It can work with all kinds of closed canister. Many types of sterile products can be tested with the SM86 sterility test system, including: â?? LVP(Large Volume Parenteral) in Glass bottle, plastic bottle, soft pouch, etc. â?? Injection in Ampoule and vial, and freeze-dried powder â?? Insoluble powder â?? Medical devices â?? Preloaded syringe It is to test whether testing sample contains microorganisms. The microorganisms present in the sample are captured on the microporous membrane in the closed canister by the action of directional peristaltic pressure from the SM86 pump device. Rinsing membrane to remove the bacteriostatic ingredient if samples included. Appropriate medium is pumped into each canister separately to promote the growth of the captured organisms. The canisters are incubated and examined for contamination in accordance with the relevant pharmacopoeia.
Function traits: * One key sterilization. * LK/MJG-50, LK/MJG-100 * Low Temperature: í_ 50oC * Fast: 31-55 minutes. * Wide spectrum: Compatible to 95% instruments. * Safe: Byproducts are just water & oxygen. * Low Price: Low unit price and consumable price. * Applicable to heat/moisture sensitive instruments. * No extra enhancer needed. * No erosion to instruments. * Instruments can be used right after sterilization is finished. * Long distance operation/monitoring (optional). * Build-in biological incubator (optional). * Foot door switch (optional). Application scope: Metal instruments: stainless steel, aluminum, bronze, titanium, etc. Non-metal instruments: glass, plastic (poly-acetyl, ethenyl, styrenepolymers, polycarbonate, ethylene resin, poly methyl methacrylate, non-woven fabrics, polyurethane, polyvinyl chloride, nylon).
Liva EAS501 M Air Sterilizer&Deodorizer 340(W) x 360(D) x 1790(H)mm 67kg 165.3m2 220V, 60Hz, 70W White / Mirror Environmentally-friendly aluminium Moving wheels can be fixed Three outlets (front, left, right side) Combined filter(prime filter, activated carbon filter and HEPA 13 filter) Sterilization modules(20 pieces of UV-LED light, 8 pieces of photo catalyst ) activated carbon filter One-button start Power reminder: LOGO light Operation: Four indicators stand for different scale of wind force Inspection : The fault indicator(Fan/UV/Filter) is on to remind customers to replace filter/sterilization modules or check fan failure 1.Three steps of filteration Medium filter: Eliminates large particles, like dust, hair, pollen, etc. Activated carbon filter: Removes harmful chemical pollutants and absorbs odor. HEPA filter (H13): Traps microscopic dust(down to 0.3 microns) Medium filter/Activated carbon filter/ HEPA filter (H13) 2.The high reactive hydroxyl radicals (-OH) is formed after the titanium dioxide(TiO2) photocatalyst is irradiated by the UV-A light. The high reactive hydroxyl radicals (-OH) initiates redox processes leading to the degradation/mineralization of adsorbed organic and inorganic compounds. Meanwhile, the reactive species will cause deleterious alterations in cellular structure, microbial inactivation and possible destruction. Polluted air(mixed with bacteria& odors)/Formation of -OH/ React with the cell wall/ Destroy the cell wall and form harmless water. 3.The functions of the high reactive hydroxyl radicals (-OH): Sterilization& Deodorization Fitted with four sterilization modules, the air flow will be sterilized and deodorized for as many as six times. LIVA air sterilizer & deodorizer uses photocatalyst(Tio2) and UV-A irradiation to sterilize the pathogenic microorganisms, harmful chemical gases and dust(pm2.5). With the irradiation of UV-A, Tio2 will form hydroxyl radical which is highly reactive and will degrade the pollutants & microorganisms into Co2 and H2o.There are 4 sets of sterilization module in each machine, and� the route of module is ingeniously designed enabling the pollutants & microorganisms to be sterilized for 6 times. That is why LIVA air sterilizer can achieve more than 98% sterilization rate, which is much higher than other companies' products.
340 X 360 X 1770mm 67kg 165.3m2 220V, 60Hz, 70W White Environmentally-friendly aluminium Moving wheels can be fixed Three outlets (front, left, right side) Combined filter(prime filter, activated carbon filter and HEPA 13 filter) Sterilization modules(20 pieces of UV-LED light, 8 pieces of photo catalyst ) activated carbon filter One-button start Power reminder: LOGO light Operation: Four indicators stand for different scale of wind force Inspection : The fault indicator(Fan/UV/Filter) is on to remind customers to replace filter/sterilization modules or check fan failure FUCTION 1.Three steps of filteration Medium filter: Eliminates large particles, like dust, hair, pollen, etc.Activated carbon filter: Removes harmful chemical pollutants and absorbs odor.HEPA filter (H13): Traps microscopic dust(down to 0.3 microns)Medium filter/Activated carbon filter/ HEPA filter (H13) 2.The high reactive hydroxyl radicals (-OH) is formed after the titanium dioxide(TiO2) photocatalyst is irradiated by the UV-A light. The high reactive hydroxyl radicals (-OH) initiates redox processes leading to the degradation/mineralization of adsorbed organic and inorganic compounds. Meanwhile, the reactive species will cause deleterious alterations in cellular structure, microbial inactivation and possible destruction. Polluted air(mixed with bacteria& odors)/Formation of -OH/ React with the cell wall/ Destroy the cell wall and form harmless water. 3.The functions of the high reactive hydroxyl radicals (-OH): Sterilization& Deodorization Fitted with four sterilization modules, the air flow will be sterilized and deodorized for as many as six times. LIVA air sterilizer & deodorizer uses photocatalyst(Tio2) and UV-A irradiation to sterilize the pathogenic microorganisms, harmful chemical gases and dust(pm2.5). With the irradiation of UV-A, Tio2 will form hydroxyl radical which is highly reactive and will degrade the pollutants & microorganisms into Co2 and H2o. There are 4 sets of sterilization module in each machine, and the route of module is ingeniously designed enabling the pollutants & microorganisms to be sterilized for 6 times. That is why LIVA air sterilizer can achieve more than 98% sterilization rate, which is much higher than other companies' products.
Capacity: 24, 45, 60, 80 LITERS CLASS B -An automatic high pressure rapid sterilizer which works with steam as medium. -Can be widely used in department of stomatology and ophthalmology, operating room, CSSD. -Suitable for all (un)wrapped solid instruments, A-class cavity instrument (Dental hand piece), implantable instruments, dressing fabric and rubber tubes, etc. -Stainless steel 304 chamber structure: cylinder, horizontal, single door. -Door opening method: automatic, press button. -High efficient WJS (water ejector) vacuum system, which supply high speed vacuum and low working noisy, vacuum lower limit can reach over -90kPa in short time, perfect drying performance through sterilization. Device / Programs: - 8 preset cycles - Cycle time: 45-60 min, according to different loadings - Pressure display: Analogue pressure gauge for chamber on right side - Temperature display: Digital Temperature Display on the front panel (LCD screen) - Built-in steam generator: Double Instant steam generator - Integrated programmable PLC control system with 3.2 inch LCD screen display and capacitive induction buttons enables intuitive operation. It shows the pages which are: main menu, library cycles, cycle parameters, process control, display of temperature, pressure, time, running process, error and alarm information, various of messages (working status, temperature, pressure, vacuum, etc.) Installation - Designed Pressure: -0.1~ 0.3 MPa - Vacuum low limit: -0.09 MPa - Vacuum pulses counts: 0~99 items - Designed Temperature: 144�° C - Working Temperature range: 105-138�° C - Power Supply: control Power: AC 220V �± 10% single phase 50/60 Hz - Input power: 2.6kVA (24L) or 6.8kVA (45L) or 7.4kVA (60L) - Water pure supply, inner circulation, with open type water tank with removable cover makes it easy to be cleaned Data Saving: - Sterilization cycle data (batch number date/time, temperature/pressure progress and sterilization phase) can be printed using an integrated micro printer (optional) via RS232 serial port - Data can also be stored via U disk (optional), stores up to 10 000 sterilization cycles - WI-FI module allows real time transmission of cycle data and cycle progress information to a PAD for online monitoring (documented data both graphically and numerically and can be used for control of autoclaves)