Quick Sense(Qs-WR02): Wardrobe/Cabinet Smart IR Sensor
Quick Sense(Qs-WR03): Mirror/Hand Smart IR Sensor for Auto Lights Auto On and Off Upon Moving Hand
Power source: 220-240V/AC
Power Frequency: 50/60
Install the product on the wall with two enclosed inflated s
Connecting the power and the load to the sensor as the connection-wire diagram
Switch on the power an
It is a Short Distance IR Sensor. Its ON or OFF is controlled by hand movements. When you move your hands towards the IR sensor, it gets detection and turns on the light. The light will be switched off until the IR sensor detects another movement by hand. NOTE: In front of the detection window there shouldnâ??t be hinder or unrest objects affecting detection
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Quick Sense(Qs-WR05): Touch Smart IR Sensor for Auto Lights It is a Touch Sensor. Its ON or OFF is controlled by touch metal. When your hands touch any metal surface connected by the metal ring, it gets detection and turns on the light. The light will be switched off when your hands touch again. Power source: 220-240V/AC Power Frequency: 50/60Hz Install the product on the wall with two enclosed inflated s Connecting the power and the load to the sensor as the connection-wire diagram Switch on the power an
Quick Sense Wardrobe Cabinet Hinge LED Motion Sensor Night Light System (White, 0.25 W) - Set of 10 Pack Smart Sensor Light Specifications: Material: ABS; Color: Grey Lighting Color: Warm white/Cool white (Optional) Battery: 12V 23A(Not Included) Type: Smart Sensor; Bead Quantity of Each Light: 3pcs How to Installation: Step1: First open the hinge screws on the backsheet Step2: Put the back sheet screws and hinges screwed together Step3: Put the battery into the LED hinge light Step4: Make LED lighting into the card pre-installed on a good film Step5: Put the thickest chucking and complete Can be used in your home cabinet, closet, cupboard, or wardrobe with a hinge. Note: suitable for hinges like the picture, the screw in the hinge must be screwed off, the led light base need to be mounted in there
We Can Supply Freestyle Libre 2 Flash Glucose Monitoring System Sensor Please Dont Hesitate to Contact Us in Case of Any Interested
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.
S509 IR CO2 Gas Sensor Characteristics: * -40'C~+70'C wide working temperature range high precision measurement * Sensor automatic revision, zero drift an automatic adjustment * Immune to poisonous and harmful material, have fight poisoning efficacy * Work without oxygen to participate in * Using the infrared principle scattered, and long service life * Sensor work, can output the digital quantity and analog * Has the standard output interface, peripheral use circuit is simple Infrared gas sensor is based on bill-LangBo law and ir theory developed, we can accurately detect methane, carbon dioxide, hydrocarbons, etc. Sensor interior has intelligent processing chip, the gas absorption of light signal conversion into gas concentration information, and digital signal and linear output voltage signal and through the software algorithm in complex linearization and precise processing temperature and humidity compensation of gas density per second, and a time interval according to certain packet format automatically send output. When offered 3.0VDC ~ 6.0VDC range voltage, S509 infrared sensor can be in -40'C ~ +70'C Wide temperature range normal work. The sensor to provide analog and digital output interface. The user can through the interface auto receiving gas concentration data and execution, use the function such as calibration is very simple. S509 IR CO2 Gas Sensor Specification * Working voltage: 3.0 - 6.0V * Resolution: 1°FS. * Response timeT90: 30S * Measurement accuracy: ±3%FS * Zero repeatability: ±1%FS * Long-term zero drift: ±1%FS/year * Working temperature: -40'C~+70'C * Working humidity: 0~95%RH No condensation