Benefits
Environmental studies can now save time and money with real-time, on-the spot elemental analysis - from Magnesium to Uranium,
From PPM to 100 % - in solids, liquids, powders, cores, fragments, filters and films, slurries and more. Portable XRF provides cost-effective, timely analysis.
Innov-X combined an x-ray tube source, multiple beam filtering and the HP PDA to deliver superior limits of detection, speed, precision and upgrade capability.
Features
Superior performance of Cr and other metals. Light element Analysis Program (LEAP) analyzes P, S, Cl, K and Ca
Utilizes advanced and universal XRF data modeling:
Compton Normalization: "Internal Standard" provides for quantitative analysis without site-specific calibrations
Fundamental Parameters: Standardless, ideal for samples with high and low concentration of several elements
Empirical Calibrations: "Calibration Curves" allows user-generated calibration curves
Add new elements and calibrations easily. Innov-X analyzers will meet your requirements today and in the future
View spectra on screen
Compare spectra for comparative analysis and display results versus standards
Stored tests can be re-run with new parameters or models
Data security: stores in binary format for data intel
Commodity: Calcium carbide Molecular formula:CaC2 Molecule Weight: 64.10 H.S code:28491000 CAS: 75-20-7 UN NO.1402 HAZARD CLASS: 4.3 Application: It is a kind of basic material for organic synthesis, and can produce acetylene gas for cutting and welding, also be material for calcium cyanamide. Appearance: Grey, black solid, purple when its purity is more than 90%. Granule:4-25mm / 15-25mm / 25-50mm / 50-80mm /25-80/ 80-120mm Package: Net in 100kg or 50kg new iron drums with nitrogen. Specification: GB10665-2004 Specification Superfine Grade First Grade Second Grade Gas yield(L/kg)L/kg 305 295-305 285-295 PH3 content in acetylene (PH3%) 0.06 0.08 0.08 H2S content in acetylene (H2S%) 0.1 0.1 0.1 Loading weight in 1 x 20fcl:22.5mt
Commodity: Calcium chloride Molecular formula CaCl2 H.S code 28272000 Product feature Calcium chloride is an inorganic salt, which exists as solid or liquid. Solid calcium chloride is a white, crystal substance in the form of flake, granule, pellet or powder. With different crystallized water contents, it can be dihydrate or anhydrous. Liquid calcium chloride is a colorless, clear solution. As calcium chloride has such properties as quick dissolving, exothermic ability, attracting moisture from the air and surroundings, dissolving at very low temperature, Specifications: Analysis Item Standard Calcium chloride (CaCl2) 74%min,77% min,94%min Total Chlorinated Alkali: (NaCl) 5.0%max Magnesium Chloride(MgCl2) 0.5%max Insoluble matter in water 0.25%max Calcium Sulfate (CaSO4): 0.2%max Ferric Oxide (Fe2O3) 0.025%max Heavy Metal as Cu., Pb., Cd., Cr., Hg., As 0.005%max Application Mainly used in drying, melting snow for airport express and street, concrete desiccant and concreting fast, removing dust and oil industry. Exporting Packing :Plastic woven bag with PE ,25kg/50kg/1000kgs net weight or 25kg x 40 bags into one big bag or 40 bags on a pallet with shrink-wrapped Means of transportation :in containers or by bulk vessel with large quantity
Description The Innov-X Omega X-Ray fluorescence spectrometer is a handheld XRF analyser. With its ultra rugged design, diverse field analysis is possible in any conditions. The XRF delivers fast and precise identification and analysis of elements from phosphorus to uranium (P to U). Advantages of Field Portable XRF. In the past, studies relied exclusively on expensive and time consuming analysis based on samples that hopefully characterised the site. The portable XRF has revolutionised environmental investigations by allowing you on-the-spot elemental analysis, in real time. Measure the composition of soils, debris, run-off streams, dust wipes, coatings, corings, paints, plastic and wood instantly,saving you time and money. From phosphorus to lead, from low ppm to 100% - in soils, solids, liquids, powders, cores, fragments, filters & films, slurries and more. One simple test can analyse up to 25 separate elements in seconds, including priority pollutants. Determine zonal and contamination patterns; track pollutant migration caused by extreme weather; perform real-time surveys to delineate and define metals present. In-situ soil analysis for rapid, comprehensive site investigations: Delineate metals present and contamination patterns Measure high volume field tests to minimise laboratory analytical costs Test soil directly through plastic corings or bagged samples Establish contamination boundaries and depth profiles for remediation and disposal Collection of samples to produce rock-solid analytical data at the site: XRF is non-destructive submit same sample for laboratory confirmation Ensure validation requirements/targets are met on-site in real time Prepared soil sample testing assures the maximum possible accuracy Ultimate XRF Performance with Silicon Drift Detector (SDD) Technology The Innov-X Omega Xpress and Omega Xpress Vacuum Alloy Analyzers utilize the latest in detector technology - an innovative, large area Silicon Drift Detector (SDD), commonly used and tested extensively in high end, laboratory based instrumentation. In comparison to a traditional Si PiN Diode detector, the SDD provides: 10x improvement in signal to background ratio Marked resolution improvement, from 195eV to 165eV The capacity to handle 10x more counts Key benefts to the user: >3x improvement in reading speed. Light element (Mg, Al, Si, P, S) analysis in air 3x better limits of detection for sensitive tramp elements
Metal tin is mainly used in the manufacture of alloys. Tin and sulfur compounds - tin sulfide, which is similar in color to gold, is commonly used as a gold pigment. Tin's modern application is as a solder for the electronics industry. Used in various purities and alloys (often with lead or indium), tin solders have a low melting point, which makes them suitable for bonding materials. Standard ASTM B29-03, BS EN 12659:1999, GB/T 469 -2005 , Content Pb â?¥ 99.99 % Density 11.34 g / cm 2 Color Bluish Weight 35 kgs / lump, 55 kgs / lump Dimension 21" x 4" x 2.5" Package Standard Sea-worthy package, fixed by belt per ton Shape Rectangular Lump Application lead-acid storage batteries Ammunition, cable sheathing, and building construction materials counterweights, battery clamps cast products such as: bearings, ballast, gaskets, type metal, terne plate, and foil Container Size 20Gp - 2.352(width) *2.385 ( Height ) * 5.90 ( Inside length ) Meter 40Gp - 2.352(width) *2.385 ( Height ) * 11.8 ( Inside length ) Meter 40HQ - 2.352(width) *2.69 ( Width ) * 5.90 ( Inside length ) Meter
Product Name: Alpha-Bisabolol "Type: Cosmetic Grade Origin: China CAS No.: 515-69-5 AUCO No.: 116 Packing: 25kg drum" Items Standard Appearance Colorless to straw yellow viscous liquid Identification The infrared spectrogram of the item should be consistent with the reference substance of a-Bisabolol Density 0.924-0.930 Refractive index 1.493-1.498 Residue on ignition
Product name: N,2-diethyl-2-(isopropyl)-3-methylbutyramide Other Name: N-ethyl-2,2-diisopropyl butanamide;WS-27 Kinds: WS-23, WS-3, WS-5, WS-12, WS-10, WS-27 Molecular Formula: C12H25NO Molecular Weight: 199.33 Appearance: White crystal powder Purity: 99% CAS NO.: 51115-70-9 EINECS No.: 256-978-6 Supplier: ZhenYiBio Relative Cooling Strength at First Onset WS-5>WS-12>WS-3>Menthyl acetate>WS-23>Menthyl lactate Cooling Longevity WS-12>WS-5>WS-23>WS-3>Menthyl acetate>Menthyl lactate WS-27 is a newly developed flavor coolant of the WS series. Compared with the coolant WS-23, it is more delicate and easier to dissolve. We developed a proprietary process to provide the WS-27 with a high purity product that does not have the bitter aftertaste of previous products. It mainly affects the front of the mouth and the tongue. And it has a high burst and high intensity of cooling sensation, suitable for a variety of products.