1. For babies and toddler
2. Safe and hygienic
3. Soft, reusable silicone tip
4. Ultra Silence Design
5. Ergonomic design
6. Easy-to-clean collection cup
7. Quickly & gently remove excessive mucus
8. Provide relief and a quicker recovery
9. Reduce the risk of repetitive colds
Rs 1.82 Lakh / PieceGet Best Price Minimum Order Quantity: 1 Piece Power (kVA) 5 kVA Genset Brand KOHLER Model Number KDG0005P2 Phase Single Phase AMC Available On-site Service Available Country of Origin Made in India KOHLER SILENT DIESEL GENERATOR 5 KVA MODEL KDG0005P2 50 HZ SINGLE PHASESpecial Featuresâ?¢ Natural aspirated, air cooled diesel engine with superior efficiency and operating economyâ?¢ Integral vibration isolation eliminates the need for under-unit vibration spring isolatorsâ?¢ Advanced Digital Controller (ADC) with 3 auto crank cyclesâ?¢ Alternator features: Alternator meets Indian and international standards Self-ventilated and dripproof of IP23 construction Superior voltage waveform by 2/3 pitch wound stator Sustained short circuit current of up to 300% of the rated current for up to 20 secondsâ?¢ Silencer located inside canopyâ?¢ On field convertability from manual to AMF Additional Information: Delivery Time: 10 days
Water Cooled Diesel Generator Sets 1) Rated power: 10-200kw 2) Fudon diesel engine 3) Brushless alternator 4) Silent or open General Technical Data: 1. Engine: brand new FUDON water cooled diesel engine 2. Alternator: brushless alternator 3. Output range: 10-50kw 4. Frequency: 50 & 60Hz 5. Speed: 1500 or 1800rpm 6. Phase: 3 Phase 4 Wire & 1 Phase 2 Wire 7. Voltage: 220/380V, 230/400V, 240/415V, etc 8. Automatic digital control panel, auto start with AMF function. Genset Features: 1. FUDON water cooled diesel engine 2. Radiator 40 C max, fans are driven by belt, with safety guard 3. Brushless alternator 4. Choice of manual/auto and AMF control panels and protection systems 5. Digital auto-start panel 6. Anti Vibration Suspension Absorber 7. Dry type air filter, fuel filter, oil filter 8.10-hour operation base tank 9. Mould case circuit breaker 10. 24V DC start motor and storage battery 11. 24V charge alternator 12. 24V batteries, rack and cable 13. Ripple flex exhaust pipe, exhaust siphon, flange, and muffler 14. All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load, 110% load and all protection function (over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop). Engine Features: 1. FUDON water cooled diesel engine 2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection 3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler 4. Machinery or electronic governing 5. Fuel injection pump 6. Electric motor starting system 7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner 8. Low discharge, and low fuel consumption 9. Installed conveniently and maintain easily Alternator Features: 1. Good quality alternator 2. Brushless, 4 poles, rotation magnet 3. IP21-23(NEMA1) enclose is standard for all industrial alternators 4. H class insulation system 5. AVR self-regulated, voltage regulation rate: ≤ ± 1% 6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts 7. Wide range of flange adaptors and single bearing disc coupling 8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528 9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof Soundproof/Silent Box: 1. Excellent ventilation 2. Oil tank mounted on base frame for 12 Hours working 3. Highly Corrosion Resistant construction 4. Excellent Access for Maintenance 5. Security and Safety 6.1m
RAISE welding generator provides single-phase and three-phase output function welding 1.Excelent welding performance ,suitable for steel pipe and pipe welding. 2.Adjustable welding current 3.Welding points are stable Unit structure: built-in frame type, two hand-push wheels performance: Current adjustment range: 50~220A No-load welding voltage: DC65V Welding voltage: DC23~30V Back load rate: 15% (5 electrode) 50% (4 electrode) Welding rod: 2.5~5.0 Generating power: 2.5KW Rated frequency: 50Hz Rated voltage: 220V Excitation mode: AVR automatic adjustment Fuel tank capacity/working time: 12L/6 hours engine: Engine model: RZ188FA/E Engine form: single-cylinder four-stroke air-cooled Bore x Stroke: 88 x 75 Displacement: 456cc Fuel type: 0# in summer, -10# in winter Lubricant model: SAE15W/30 Lubricant capacity: 1.65L Start mode: hand pull start / or electric start Battery capacity: 20Ah Boxed data: Unit size: 720x490x620 Packing size: 735x505x645 (carton) Net/Gross: 100/103
RAISE welding generator provides single-phase and three-phase output function welding 1.Excelent welding performance ,suitable for steel pipe and pipe welding. 2.Adjustable welding current 3.Welding points are stable Unit structure: built-in frame type, two hand-push wheels performance: Current adjustment range: 50~220A No-load welding voltage: DC65V Welding voltage: DC23~30V Back load rate: 15% (�¦5 electrode) 50% (�¦4 electrode) Welding rod: �¦2.5~�¦5.0 Generating power: 2.5KW Rated frequency: 50Hz Rated voltage: 220V Excitation mode: AVR automatic adjustment Fuel tank capacity/working time: 12L/6 hours engine: Engine model: RZ188FA/E Engine form: single-cylinder four-stroke air-cooled Bore x Stroke: 88 x 75 Displacement: 456cc Fuel type: 0# in summer, -10# in winter Lubricant model: SAE15W/30 Lubricant capacity: 1.65L Start mode: hand pull start / or electric start Battery capacity: 20Ah Boxed data: Unit size: 720x490x620 Packing size: 735x505x645 (carton) Net/Gross: 100/103
Supplier: Gasoline/diesel generator, generating sets, ultra silent power station, gasoline/diesel pump, pump units, customized generator/pump
Services: Exporting, after-sales service
EAP 33 Engine: PERKNS Engine Model : 1103A-33G Stand By kVA: 33 Stand By kW : 26,4 Prime kVA: 30 Prime kW : 24 Rated Current : 43,2 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKNS Engine Model 1103A-33G Number of Cylinders 3 Inline Injection System Direct Compression Ratio 19.25:1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 8,3 Standby Power kw / Hp 30,4 / 41 Prime Power Hp 27,7 / 37,3 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 8 Fuel Consumption (lt / h) Lt Full Load 7,2 Lt %75 LOAD 5,6 Lt %50 LOAD 4 Frequency Hz Power kVA 33 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 980 Weight (Open) Kg 825 Width (Silent) Mm 900 Length (Silent) Mm 2200 Height (Silent) Mm 1350 Fuel Tank Capacity Lt 135 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 22 Engine: PERKINS Engine Model : 404A-22G1 Stand By kVA: 22 Stand By kW : 17,6 Prime kVA: 20 Prime kW : 16 Rated Current : 28,8 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKINS Engine Model 404A-22G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 23.3:1 Bore 84 Strok 100 Displacement Lt 2,21 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 10,6 Standby Power kw / Hp 20,6 / 27,8 Prime Power Hp 18,7 / 25,2 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 14 Fuel Consumption (lt / h) Lt Full Load 5,3 Lt %75 LOAD 4 Lt %50 LOAD 2,9 Frequency Hz Power kVA 22 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 720 Weight (Open) Kg 590 Width (Silent) Mm 950 Length (Silent) Mm 2000 Height (Silent) Mm 1200 Fuel Tank Capacity Lt 125 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 17 Engine: PERK NS Engine Model : 403A-15G1 Stand By kVA: 17 Stand By kW : 13,6 Prime kVA: 15,4 Prime kW : 12,3 Rated Current : 22,1 Engine - PERK NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKNS Engine Model 403A-15G1 Number of Cylinders 3 Inline Injection System InDirect Compression Ratio 22.5:1 Bore 84 Strok 90 Displacement Lt 1,49 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 6 Standby Power kw / Hp 13,2 / 17,7 Prime Power Hp 12 / 16,1 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 6 Fuel Consumption (lt / h) Lt Full Load 3,9 Lt %75 LOAD 2,9 Lt %50 LOAD 2 Frequency Hz 50 Power kVA 15 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 545 Weight (Open) Kg 500 Width (Silent) Mm 950 Length (Silent) Mm 2000 Height (Silent) Mm 1200 Fuel Tank Capacity Lt 125 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 30 Engine: CUMM NS Engine Model : 4B3.9-G1 Stand By kVA: 30 Stand By kW : 24 Prime kVA: 27,2 Prime kW : 21,8 Rated Current : 39,2 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM NS Engine Model 4B3.9-G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.3: 1 Bore 102 Strok 120 Displacement L 3,9 Air Intake Natural Aspiration Speed (RPM) 1500 Oil Capacity L 3,9 Standby Power kw / Hp 27 / 36 Prime Power Hp 24 / 32 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 8,3 Fuel Consumption (lt / h) L Full Load 7,1 L %75 LOAD 5,7 L %50 LOAD 4,3 Frequency Hz Power kVA 30 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 880 Weight (Open) Kg 725 Width (Silent) Mm 900 Length (Silent) Mm 2200 Height (Silent) Mm 1350 Fuel Tank Capacity L 135 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.