Kaye Inst. HTR 300 Probe Calibrator
Kaye Inst. HTR 300 Temperature Probe Calibration:
The Instrument is offered AS IS. Freight/Shipping is not included in offer price.
The unit is visually refurbished and is turning on, But we have no capability to real sample testing or calibration.
GBCDG31FF021SBCH IDMT 2 O/C & 1 E/F RELAYS SPL 150 HZ. Technical specification Relay model No CDG31FF021SBCH Relay type CDG 31 Special Case size 3D V 20T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Current setting - E/F 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R Taps Std BURDE / D.M.T 3 VA / 3 Secs C.T.Secondary 5 amps Frequency 150 Hz Flag Yes Mounting Flush Note to test:Relay to test 150 Hz. refer test inst. Name Plate RFG9126 903 Outline drawing MFJ 013 Wiring diagram MFDZ 801.101-1
Digital Trainer is intended for elementary as well as advance training of Digital electronics and for bread board digital circuits, AND, OR, NOT, NAND, NOR, XOR, Three State Buffer, RS Latch, JK Flip Flop, Monostable Multibrator. and UP/ DOWN Counter. Practical experience on this board carries great educative value for R & D labs, Science and Engineering Students. Specifications: 01. Breadboard : Solderless Bread board with 1680 inter connected Tie Points 02. Pulse Switches : 2 No?s. Bounce free push buttons 03. Logic Switches : 8 logic level Switches in Dip type . 04. Power Supply : Fixed: +5V at 750 mA 5. Power Sockets : Logic Probe Power Supply Sockets 06. Logic Input : 8 LED buffered logic level indicators 07. Variable Clock : Fine adjustment of clock frequency. Clock range selection L : 10 ? 40 Hz, H : 1K ? 20K Hz. 08. Jacks : 2mm to BNC Socket 2 No. 2mm to 4mm Socket 2 No.
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.
Cable Standard BS 6500 & IS 694:2010, IEC 60227 Silent Features - High flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Inner Sheath PVC Outer Sheath PVC As Per IS:5831 Core Color As per IEC 60227 3C -Blue, Brown, Black or Yellow/ Green, 4C -Blue, Brown, Black, Grey or Yellow/Green As per IS 694 : 2010 - 3C - Red, Yellow and Blue 4C - Red, Yellow, Blue and Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply.
Cable Standard BS:5308 (172) IEC 189 (1&2) Silent Features - Wear & Tear Resistance - Long Life - Easy to Cable Slitting - Fire Resistance Technical Data Working Temp : 70C / 90C / 105C as per Insulation Nominal Voltage : 300/500 V Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application Standard Packing Coils 100, 200, 500 & 1000m Conductor Annealed Plain Bare Copper or Tinned Copper As per IEC 60228 Insulation PVC/ XLPE/ PE/ LSZH/ EPR Sheath PVC/ Rubber/ LSZH/ FRLS Type Armoured or Unarmoured. Elements Insulated core/Pairs / Tried / Quads Color / multi core cable number marking on core Shield Aluminum mylar tape screen with tinned copper drain wire individual shielding or Overall Shielding Braiding Tinned copper braiding as per requirement Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application
Cable Standard Generally conforms to DIN VDE 0281-5&2, BS:6500, EN-50525-2-11, IEC 60227-5 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistance to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -5C to 70C Operating Temp : 20c to +80C Nominal Voltage : 300/500 V Test Voltage : 2000V Min. Bending Radius : 6x Cable Diameter Standard Packing Coils 100, 200, 500 and 1000m Conductor Annealed flexible bare Copper (Class 5 - Flexible Plain Copper) according to VDE 0295 IEC 60228. Insulation PVC T12 to according to EN 50363-3, BS 7655 Sheath PVC TM2.to according to EN 50363-3, BS 7655 Color White, Black, Blue or as per customer order Core Identification 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/green, Brown, Black, Grey 5 Core - Yellow/green, Blue, Brown, Black and Grey Application H05VV-F cordage is a flexible PVC insulated, PVC jacketed harmonized cord recommended for use in electronic and electrical equipment such as office.
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Introduction Application: used in connecting for audio appliances, home appliances, small electric tolls and instruments. Construction:Stranded copper conductor or Tinned Copper, PVC insulated, twin parallel or twisted. Rated Voltage:300/300V Standard: IEC227 CE, RoHS, CCC, ISO certificated Package:coils with plastic film and wooden pallet.or plastic/wooden reel Quick Delivery,OEM available Specification Normal area(mm2)Structure(mm)Insulation thickness(mm)Overall dia.(mm) 2X0.507X9/0.100.72.20X4.40 2X0.757X14/0.100.72.40X4.80 2X1.007X18/0.100.82.60X5.20 2X1.507X27/0.100.93.10X6.20 2X2.007X36/0.1013.90X7.80 2X2.507X45/0.101.24.20X8.40 2X4.007X72/0.101.34.80X9.60
OM3 fiber optic cable is designed to accommodate 10 Gigabit Ethernet up to 300 meters. OM3 Fiber compatible with Gigabit Ethernet 1000Base, or 10GBase, and Fibre Channel. IL & RL requirement. Customized specification