Please click here to check who's online and chat with them.

Ggd Capacitance Compensation Cabinet

Supplier From China
Apr-18-20

Most load types in power system belong to inductive load. In addition, power electronic devices are widely used in power enterprises, so the power factor of power grid is low. Lower power factor reduces equipment utilization ratio, increases power supply investment, damages voltage quality, reduces equipment service life, and greatly increases line loss. In order to improve the energy waste caused by the low power factor of power grid and these unfavorable factors of power supply production, it is necessary to effectively improve the power factor of power grid. Obviously, it is unreasonable and usually impossible for these reactive power to be supplied by generators and transmitted over long distances. Reasonable way is to generate reactive power where reactive power is needed, that is, to increase reactive power compensation equipment and devices.
II. Structure Composition
Generally speaking, low price Capacitance Compensation Cabinet is composed of cabinet shell, bus, circuit breaker, disconnector, thermal relay, contactor, lightning arrester, capacitor, reactor, primary and secondary conductor, terminal row, power factor automatic compensation control device, panel instrument, etc.
III. Basic Principles
In the actual power system, most of the loads are asynchronous motors. The equivalent circuit can be regarded as a series circuit of resistance and inductance. The phase difference between voltage and current is large and the power factor is low. After shunt capacitors are connected, the current of capacitors will offset part of the inductance current, so that the inductance current decreases, the total current decreases, the phase difference between voltage and current decreases, and the power factor increases.
A reactive power automatic controller is installed in the compensation cabinet, which automatically puts in or removes capacitors according to the load force rate. The main function of the controller is to make the load close to the required reactive current, thereby improving the power factor. For enterprises, the main reason is to avoid the penalty of power factor not up to the standard (0.9).


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Ggd Capacitance Compensation Cabinet

Jun-26-17
Supplier From Shanghai, Shanghai, China
 
GGD Type AC Low Voltage Distribution Cabinet
GGD type AC low voltage distribution cabinet
Product Introduction
Introduction and usage
GGD type AC low voltage distribution cabinet is suitable for power plants, substations,factories,mine enterprises whose distribution system is with 50HZ AC,to 3150A rated working current, used for power change,distribution and control of power, lighting and power distribution equipments.
GGD AC low voltage distribution cabinet is a kind of new type low-voltage distribution cabinet, designed based on the requirements of the Department of Energy in charge  of the higher level, the majority of electricity users and design department, and with principles of safe, economic, rational and reliable. It is with these characteristics of high breaking capacity, good dynamic thermal stability, flexible electrical program, convenient combination methods, series, practical, novel structure, high level of protection, can be treated as a replacement product of low voltage switchgear assemblies.
GGD type AC low voltage distribution cabinet meets the standard of IEC43Low-voltage switchgear and control gear, GB7251Low-voltage switchgear assembliesOperational conditions
1, surrounding air temperature not more than +40°C, not less than -5°C, average temperature over 24hs cannot more than +35°C
2, installed in indoor, altitude not higher than 2000m
3, surrounding air relative humidity at the highest temperature of + 40 not more than 50%, at a lower temperature allows a greater relatively humidity( for example, temperature is + 20 , humidity can be 90%), should consider the influence of condensation caused occasionally due to the temperature change.
4,the inclination between cabinet and vertical plane not exceed 5%
5, cabinet need be installed in the place without severe vibration and shock and where is insufficient to corrode electrical components.
6,users can consult with manufacturers if have special request.
Dec-24-13
Supplier From Xiangyang, Hubei, China
Dec-27-11
Supplier From Shanghai, China
May-19-11
 
Product Structure

1. Bypass Cabinet (Optional)

The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user¡¯s working conditions. The function of by-pass cabinet is to put the motor into operation in industry frequency grid after the WLD-HVF exits, so as to ensure the continuity of user¡¯s production. The switching cabinet is designed to divert the WLD-HVF output to different motors.

2. Transformer Cabinet

Used for installation of Phase-shift transformer, it is dry type transformer with functions of temperature display and over-heat protection, also with insulation grade of H. The secondary multi-winding output provides phase-shift power supply to the power unit. This can greatly improve the current waveform on grid side and reduce the harmonic interference of the equipment to power grid lower of the National Criterion.

3. Power Unit Cabinet

Used for installation of power units, which adopted imported high quality components inside, all power units are installed on the sliding seat, it is very easy to replace.

4. Control Cabinet

Used for installation of low voltage control components, there are controller, PLC, UPS, Electric siren, DC 24V power supply, Control Power Source Switch, Wiring Terminals, Touch Screen, Operation Button etc.

The equipment adopted fiber optical communications, which has a very good EMI restraining performance; The transformer, control cabinet and all power units, are built in temperature protection, so it will be maintenance free.

Technical Features

Voltage source High-high frequency inverter, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.
Low harmonics input and high power factor, the typical value for power factor is 0.95 through whole speed regulation, even more higher, no need for power factor compensation.
WLD-HVF output few harmonics, the motor does not generate extra heat and noise.
Modularized design of power units, interchangeable and easy to produce and repair, the equipment can find any fault exactly based on advanced diagnostic procedures in MPU.
The inverter still can operate even the faults for part of power units exists, if there are faults happen for inverter, the system can switch to power frequency through bypass function.
Applicable to all kinds of power grid at home and abroad and suitable for typical high voltage motor.
Colorful touch screen, easy to operate and maintenance.
Able to realize remote control, DCS operation and communications with Host, and support all kinds of communications interfaces such as CAN, Profibus, Modbus, RS232, RS485 etc.
Applied latest components, master control chip adopted TI¡¯s DSP F28335 and ALTERA¡¯s FPGA of EP3C to realize powerful processing capacity; Sampling adopted AD¡¯s AD7606 with 16 bit to ensure control accuracy of the system.
The switchgear can satisfy safety requirements, and the pressure-relief channel of high voltage switch can ensure safe use of operators.
Technical Parameters

Series No
Parameters
Value

1
HVF Capacity(KVA)
250~8750kVA

2
Power of adaptive motor(KW)
200~7000KW

3
Input Frequency(Hz)
45~65Hz

4
Harmonics contents injected to power grid
<3%

5
Rated input voltage(KV)
3KV/6KV/10KV ¡À10%

6
Input power factor
>0.95%(>20% of rated load)

7
Efficiency
>96%(under a rated load)

8
Output frequency(Hz)
0.5~120Hz

9
Precision of output frequency
0.01Hz

10
Rated output current(A)
36~600A

11
Overload capability
120%(1min), 150%(3s), 200%(Immediate protection)

12
Control mode
V/F control or Vector control

13
Analog input
0~10V/4~20mA

14
Analog output
0~10V/4~20mA Optional (2 channels)

15
Boolean input/output
Communications/Default point (expandable)

16
Acc & Dec time (S)
0.1~3000s

17
Altitude
<1000m

18
Protection grade
IP40

19
Cooling mode
Forced air cooling

20
Operation environment temperature
0~400C

21
Noise
<70DB

22
Communication with host
CAN, Profibus, Modbus, RS232, RS485 etc


Service

1. Perfect quality and service system

The company complies with ISO9001:2008 strictly to carry out production, process etc.

2. Pre-sale Service

Investigate and Survey onsite; Provide Feasibility study report; Assist in equipment specification selection; Analyse estimated energy saving effect etc

3. In-sale Service

Provide onsite installation and debugging training, Operator training, design paper&corresponding program, energy saving estimation and measuring etc

4. After-sale Service

The 24-hour timely and all-round service is available for all WLD-HVF users; Providing lifetime maintenance, onsite fault diagnosis, remote diagnosis etc.


Wooden case (Fumigation).
May-17-11
 
Product Structure

1. Bypass Cabinet (Optional)

The by-pass cabinet or switching cabinet may employ isolating breaker, vacuum contactor or the combination, depending on the user¡¯s working conditions. The function of by-pass cabinet is to put the motor into operation in industry frequency grid after the WLD-HVF exits, so as to ensure the continuity of user¡¯s production. The switching cabinet is designed to divert the WLD-HVF output to different motors.

2. Transformer Cabinet

Used for installation of Phase-shift transformer, it is dry type transformer with functions of temperature display and over-heat protection, also with insulation grade of H. The secondary multi-winding output provides phase-shift power supply to the power unit. This can greatly improve the current waveform on grid side and reduce the harmonic interference of the equipment to power grid lower of the National Criterion.

3. Power Unit Cabinet

Used for installation of power units, which adopted imported high quality components inside, all power units are installed on the sliding seat, it is very easy to replace.

4. Control Cabinet

Used for installation of low voltage control components, there are controller, PLC, UPS, Electric siren, DC 24V power supply, Control Power Source Switch, Wiring Terminals, Touch Screen, Operation Button etc.

The equipment adopted fiber optical communications, which has a very good EMI restraining performance; The transformer, control cabinet and all power units, are built in temperature protection, so it will be maintenance free.

Technical Features

Voltage source High-high frequency inverter, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.
Low harmonics input and high power factor, the typical value for power factor is 0.95 through whole speed regulation, even more higher, no need for power factor compensation.
WLD-HVF output few harmonics, the motor does not generate extra heat and noise.
Modularized design of power units, interchangeable and easy to produce and repair, the equipment can find any fault exactly based on advanced diagnostic procedures in MPU.
The inverter still can operate even the faults for part of power units exists, if there are faults happen for inverter, the system can switch to power frequency through bypass function.
Applicable to all kinds of power grid at home and abroad and suitable for typical high voltage motor.
Colorful touch screen, easy to operate and maintenance.
Able to realize remote control, DCS operation and communications with Host, and support all kinds of communications interfaces such as CAN, Profibus, Modbus, RS232, RS485 etc.
Applied latest components, master control chip adopted TI¡¯s DSP F28335 and ALTERA¡¯s FPGA of EP3C to realize powerful processing capacity; Sampling adopted AD¡¯s AD7606 with 16 bit to ensure control accuracy of the system.
The switchgear can satisfy safety requirements, and the pressure-relief channel of high voltage switch can ensure safe use of operators.
Technical Parameters

Series No
Parameters
Value

1
HVF Capacity(KVA)
250~8750kVA

2
Power of adaptive motor(KW)
200~7000KW

3
Input Frequency(Hz)
45~65Hz

4
Harmonics contents injected to power grid
<3%

5
Rated input voltage(KV)
3KV/6KV/10KV ¡À10%

6
Input power factor
>0.95%(>20% of rated load)

7
Efficiency
>96%(under a rated load)

8
Output frequency(Hz)
0.5~120Hz

9
Precision of output frequency
0.01Hz

10
Rated output current(A)
36~600A

11
Overload capability
120%(1min), 150%(3s), 200%(Immediate protection)

12
Control mode
V/F control or Vector control

13
Analog input
0~10V/4~20mA

14
Analog output
0~10V/4~20mA Optional (2 channels)

15
Boolean input/output
Communications/Default point (expandable)

16
Acc & Dec time (S)
0.1~3000s

17
Altitude
<1000m

18
Protection grade
IP40

19
Cooling mode
Forced air cooling

20
Operation environment temperature
0~400C

21
Noise
<70DB

22
Communication with host
CAN, Profibus, Modbus, RS232, RS485 etc


Service

1. Perfect quality and service system

The company complies with ISO9001:2008 strictly to carry out production, process etc.

2. Pre-sale Service

Investigate and Survey onsite; Provide Feasibility study report; Assist in equipment specification selection; Analyse estimated energy saving effect etc

3. In-sale Service

Provide onsite installation and debugging training, Operator training, design paper&corresponding program, energy saving estimation and measuring etc

4. After-sale Service

The 24-hour timely and all-round service is available for all WLD-HVF users; Providing lifetime maintenance, onsite fault diagnosis, remote diagnosis etc.


Wooden case (Fumigation).
Nov-23-10
 
Detailed Product Description

PI7800 series energy saving cabinet (frequency inverter AC drives)

Main technical features:
1) Power range: 11~630KW
2) Voltage: 3AC 220/380/440V -15%~15%
3) Output frequency: 0.00 ~ 800.00Hz
4).Central control module based on DSP,realizes high-speed and high performance control.
5).Integrate V/F control,V/F+PG control,vector+PG control.
6).3 space voltage vector waveform produce methods.
7).Dead compensate function,realize low frequency and large output torque control.
8).Automatic slip compensate .
9).At most 7 steps speed control and 8 steps acceleration control can be realized.
10).6 programmable output control terminals.
11).Internal PID function,realize high performance closed loop control.
12).PID regulate DC braking.
13).Speed pursue starting and restart after momentary power loss.
14).Forced communicated function ,support standard RS485 and Can Bus,supply remote keyboard control function.
15).Special converse module (IGBT) temperature control function,adjustable fan control,timely reduce motor noise and temperature.
16).High-efficient faults inquiry and record function ,conveniently obviate the fault.
17).paramater protection function
18).Unique design,make frequency converter least pollution to the power.
19).Outstanding behave 3-phase AC synchronous motor of permanent magnetism control.
20) Control mode: Vector control with PG (VC), sensorless vector control (SVC), V/F control
21) Overload capacity: 150% rated current for 60 s (SVC), 180% rated current for 10 s (VC)
22) Multi-functional Quick/Jog key: Access common used parameter quickly
23) Ambient temperature: -10~40 degree
24) Altitude: 0~1000 m, 1000~4000 m with derating
25) 30 kinds of protection function
26) User can plug in option card to achieve specialized inverter for different application
27) Avoid high temperature and moisture and avoid being wetted due to raining, with the humidity below 90%RH (not dewing).

Typical application:Injection molding machine, Air compressor, Pressing machine, Air conditioner

Paper Carton or Wooden Carton.
Apr-18-20
 
WSD-GZTW-2 is a communication power supply designed for different capacity users. The system configuration consists of monitoring module, communication power module, AC/DC monitoring module, insulation monitoring module, battery patrol module, switch monitoring module, distribution unit, storage battery and cabinet body
â? .Direct Current Panel
WSD-GZTW-2 Microcomputer Controlled Communication Power Supply Screen is a communication power supply designed for different capacity users. The system configuration consists of monitoring module, communication power module, AC/DC monitoring module, insulation monitoring module, battery patrol module, switch monitoring module, distribution unit, storage battery and cabinet body. It has the characteristics of simple operation, intelligent management, high
â?¡.System characteristics
1) Automatic switching of two AC inputs to ensure the normal operation of the system;
2) Wide range of input voltage and strong adaptability of power grid;
3) HZ-JK02T monitor, LCD display, Chinese menu, friendly and rich interface, simple and convenient key operation;
4) It has comprehensive system setup, operation information query and various alarm functions.
5) Intelligent battery charge and discharge management, perfect and reliable temperature compensation function;
6) The rectifier module adopts electrified hot plug-and-pull, which makes daily maintenance convenient and fast.
7) High precision dynamic current sharing, which can operate independently, principally or under control.
8) Extensible battery detection 2 groups 110 knots, insulation detection 240 routes, switch detection 160 routes, compatible with inverter power module, DC conversion module;
9) The system adopts multi-level password authority management to restrict the operation of unauthorized personnel and ensure the safe and reliable operation of the system.
10) Built-in RS232, RS485 two communication interfaces, through the background monitoring and operation monitoring system to implement the "telemetry, remote control, remote communication, remote adjustment" four remote functions, to achieve unattended;
11) Support RTU, CDT, MODBUS three communication protocols.
(1) Signal devices can be added according to user's needs to realize the alarm function of accident signal and warning signal.
(2) The different functions of the configuration will be different. See the function description of the module selected by the Department for details.
Jun-20-08

Ups-200Kva

$35.7k
MOQ: Not Specified
 
MTT series on-line intelligent digital UPS congregates the essence of Baykee technology and entirely broke the bottleneck technology in traditional simulation circuit era. It adopts the digital control technology, of which the core is high-speed MCU and CPLD and takes the sixth generation low-exhaust and big-power IGBT and static switch as power components. Guided by these most advanced technologies in the world, it is really the first class product
MTT series UPS also adopt 4 layer PCB and larger power. The capacity can be from 10~400KVA, widely applied in the telecommunication, bank, stock exchange center, transportation, electricity, industry etc.
B) Six technologies crystallization which breaks the profession power limitation
Full digital control system
Advanced digital electric circuit system and super stability
í(Intelligent battery management
MTT series UPS brings in advanced intelligent battery management system. This system will automatically adjust battery charge parameters according the userí»s battery configuration, and can achieve batteryí»s float and boost conversion, temperature compensation and battery charge& discharge management according to the power supply environment.
Provides intelligent detection for whole process.
The system microprocessor will continuously detect on line all powerí»s supply working status, breaker status, and all circuits working status. Any failure occurs, the detecting system will immediately alarm to the runner, while synchronously starting-up UPS protection function.
Provides intelligent communication for long-distance monitor
1. RS232 and RS485 interface realizes multi-communication and long distance monitor.
2. The choice SNMP card 100% carries out long distance supervision and network management;
3. The choice dry contact connection, adopting non source contact, efficiently carries out the supervision and control of the UPS status.

High precision SMD technology
MTT series UPS replaces traditionally insert electric circuit processing with high precession SMD technology. This innovation not only save the space but also drastically eliminate the distortion of insert components in traditional UPS circuit. Whatí»s more, it ensures the integrate circuit a safe operation and enhances its reliability & operation precision.
MTT series UPS, widely using SMD technology, is heat-resistant, highly accurate and also has an excellent filter, which greatly improves the whole performance of the UPS. It is more durable and its lifetime is prolonged by 80%.
Sixth generation IGBT, the high-speed static switch and higher reliability
High-speed switch feature of IGBT; High voltage and large current; adopting voltage drives, only needs little control power. With much lower saturation voltage, the inverter AB working efficiency much higher temperature lower, more reliable.
Ultra-clear interface information processing technology makes communication between human and machine smooth.
It provides humanized big screen LCD in both Chinese and English, intuitive view of intelligent icon status of the flow chat, tabular data, events records and menu operation in both Chinese and English.
It provides clear intuitive view for the LED work state and work flow.
Decisive environmental protected and economized technique
According to the scientific life cycle evaluation, the MTT series adopts the touch screen whose anti-aging function is excellent and the Cabinet external appearance which is fluorine carbon craft processed, which is environment protected and durable, It adopts dismountable modularized design which is easy to protect and save the resource, and new type of vortex fan who has a excellent performance of radiation and energy conservation. It introduces NO-circumfluence control circuit which is excellently energy-saving and green commutate and athwart technology which can provide clear energy. Also it brings in advanced digital circuit and high pr¿ªcised SMD technology, which prolongs the UPSí»s lifetime by 80%.

C) Other functions
í( Superior load
It is completely capable to load from 0-100% while no need to change to bypass, which make sure the output reliable.
í( Perfect protection.
It has output over/low load protection, Input surge protection, phase sequence protection; battery over charge/discharge protection; short circuit protection; over-temperature protection and so on, as well as alarming function.

High dynamic performance.
Adopting kinds of feedback control such as instantaneous control method and valid date, it achieves high dynamic adjustment and reduces the output THD.
Phase-to-phase stabilizer Independent phase-to-phase control realizes the control of instant over-loading balance, so as to reach O/P 100% unbalance load.
Optional input harmonic filter and 12 pulse rectifier effectively restrain the input THD; Raise UPS input power factor, reduce the input THD current.
Optional battery detecting module able to test the single parameters, and display on the LCD. If battery failure it will alarm to runner.

Size(W*D*H)mm 1380*950*1800
Weight(kg) 1520
Dec-15-21
 
Product description

Single phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.



Electrical parameters

Electrical parameters

Accuracy class

0.05, 0.1

Power supply

Single phase AC 85-265V, 50 60 Hz

AC Voltage output

Range

57.7V 100 V 220V 380V, Switch automatically max 500V

Adjustment resolution

0.01, 0.1, 1, 10



AC Voltage output

Range 57.7V 100 V 220V 380V, Switch automatically max

Adjustment resolution 0.01, 0.1 1, 10,

Accuracy 0.05 RG

Stability Better than 0.01 RG 1min

Distortion degree Better than 0.1 not capacitive load

Load capacity 40VA

Full load regulation rate Less than 0.01 RG

Full load regulation time Less than 1ms

Temperature drift 8 PPM C

Long-term stability 60 PPM year

Verification Status