Please click here to check who's online and chat with them.

Frp Membrane Housings W80E300

Supplier From China
Apr-10-20

Winder frp membrane housing pressure vessels
End Entry Design
Available in 150psi, 300psi, 450psi, 600psi, 1000psi, 1200psi pressure rating
Accommodates standard make 8" Membrane Element
8 Inch Side Entry frp filter housings Specification
Winder frp membrane housing pressure vessels
End Entry Design
Available in 150psi, 300psi, 450psi, 600psi, 1000psi, 1200psi pressure rating
Accommodates standard make 8" Membrane Element
8 Inch End Entry frp pressure vessels Key Features
Operating Temp Range: -10°C ---49°C
Test pressure
Standard: 1.5x Design Pressure
ASME: 1.1x Design Pressure
Internal permeate port not to exceed 125PSI(0.88 MPa)
Operating pH Range: 3 - 11
Cleaning pH Range: 2 - 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
White color is as standard. Customized colors are also available.
ASME Code stamp available upon request
Please operate in accordance with User Guide
8 Inch End Entry frp filter housings Quality Assurance
Hydro-static Leakage Test Pressure:
Standard:
100% test, not sampling
? 100,000 times cycle test
? Burst test with 6 times of its operating pressure
? 100% QA test with 1.5x design hydraulic pressure.
ASME: 1.1x Design Pressure
? 100% QA inspection and cleaning before final
packaging and delivery to customers.
? Submitted for NSF standard 61
Applications:
Winder FRP membrane housing pressure vessels are widely used for industrial waste water treatment, seawater desalination, brackish water desalination, RO system for electronics, electric power, food & beverage, metallurgy, chemical, pharmaceutical and other fields.
frp filter housings Notice:
Please operate in accordance with User Guide!
All information is subject to change without prior notice. Please contact us for the latest product information and specifications.


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Frp Membrane Housings W80E300

Sep-09-20
 
Winder Side Entry Design

Available in 450 psi pressure rating

Accommodates standard make 8" Membrane Element

Element length: 40" x (1-8)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
Winder frp membrane housing pressure vessels-450Psi

8040 frp membrane housings

Side Entry Design

Available in 450 psi pressure rating

Accommodates standard make 8" Membrane Element

Element length: 40" x (1-8)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

industrial frp membrane housings

Key Features:

Operating Temp Range: -10C ---49C

Internal permeate port not to exceed 125PSI(0.88MPa)

Operating pH Range: 3 11

Cleaning pH Range: 2 12 (less than 30 minutes)

Mirror inner wall and brightly surface.

Multi-ports option

White color is as standard. Customized colors are also available.

ASME Code stamp available upon request

Quality Assurance

Hydro-static Leakage Test Pressure:



Standard:

100% test, not sampling

Ã?? 100,000 times cycle test
Burst test with 6 times of its operating pressure

100% QA test with 1.5x design hydraulic pressure.

ASME: 1.1x Design Pressure

100% QA inspection and cleaning before final

packaging and delivery to customers.

Submitted for NSF standard 61

Applications:

Winder FRP membrane housing pressure vessels are widely used for industrial waste water treatment, seawater desalination, brackish water desalination, RO system for electronics, electric power, food & beverage, metallurgy, chemical, pharmaceutical and other fields.

Notice:

Please operate in accordance with User Guide!

All information is subject to change without prior notice. Please contact us for the latest product information and specifications.
Apr-13-20
 
Rohone® frp membrane housing pressure vessels
End Entry Design
Available in 450psi, 600psipressure rating
Accommodates standard make 8" Membrane Element
Specification
Rohone® frp membrane housing pressure vessels

8 Inch End Entry frp filter housings Design
Available in 450psi, 600psipressure rating
Accommodates standard make 8" Membrane Element

industrial frp membrane housings Key Features
Operating Temp Range: -10°C ---49°C
Test pressure
Standard: 1.3x Design Pressure
ASME: 1.1x Design Pressure
Internal permeate port not to exceed 125PSI(0.88 MPa)
Operating pH Range: 3 - 11
Cleaning pH Range: 2 - 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
White color is as standard. Customized colors are also available.
ASME Code stamp available upon request
Please operate in accordance with User Guide
Apr-10-20
 
FRP MEMBRANE HOUSINGS R80S300 - ALUMINIUM CAP
Side Entry Design
Available in 300-600 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
FRP MEMBRANE HOUSINGS Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ISO9001, ISO14001, UL/NSF
Rohone aluminium cap frp membrane housing pressure vessels
8 INCH frp membrane housing price
Side Entry Design
Available in 300-600 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ISO9001, ISO14001, UL/NSF

8 INCH frp membrane housings Key Features:
Operating Temp Range: -10°C ---49°C
Internal permeate port not to exceed 125PSI(0.88MPa)
Operating pH Range: 3 11
Cleaning pH Range: 2 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
Multi-ports option
White color is as standard. Customized colors are also available.
ASME un-Coded economy series or saving ro systems cost
Apr-10-20
 
FRP MEMBRANE HOUSINGS W80S1800
Winder frp membrane housing pressure vessels
Side Entry Design
Available in 1800 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40 x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
Specification
Winder frp membrane housing pressure vessels
industrial frp membrane housings Side Entry Design
Available in 1800 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40 x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
8 INCH frp filter housings Key Features:
Operating Temp Range: -10°C ---49°C
Internal permeate port not to exceed 125PSI(0.88 MPa)
Operating pH Range: 3 - 11
Cleaning pH Range: 2 - 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
Multi-ports option
White color is as standard. Customized colors are also available.
ASME Code stamp available upon request
Apr-10-20
 
FRP MEMBRANE HOUSINGS R80S450
Side Entry Design
Available in 300-600 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
Specification
Rohone aluminium cap frp membrane housing pressure vessels

Side Entry Design
Available in 300-600 psi pressure rating
Accommodates standard make 8" Membrane Element
frp membrane housings Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

8 INCH frp membrane housings Key Features:
Operating Temp Range: -10°C ---49°C
Internal permeate port not to exceed 125PSI(0.88MPa)
Operating pH Range: 3 11
Cleaning pH Range: 2 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
Multi-ports option
White color is as standard. Customized colors are also available. 
ASME un-Coded series for saving cost of ro systems.

Quality Assurance
Hydro-static Leakage Test Pressure:
8 INCH frp filter housings Standard: 
100% test, not sampling
? 100,000 times cycle test
? Burst test with 4 times of its operating pressure   
? 100% QA test with 1.3x design hydraulic pressure.  
 ASME: 1.1x Design Pressure
? 100% QA inspection and cleaning before final
packaging and delivery to customers.
? Submitted for NSF standard 61

8 INCH frp ro membrane housings Applications:
Rohone FRP membrane housing pressure vessels are widely used for industrial waste water treatment, seawater desalination, brackish water desalination, RO system for electronics, electric power, food & beverage, metallurgy, chemical, pharmaceutical and other fields.
8 INCH frp membrane housing price
Notice:
Please operate in accordance with User Guide!
All information is subject to change without prior notice. Please contact us for the latest product information and specifications.
Apr-10-20
 
Side Entry Design
Available in 600 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
Specification
Winder frp membrane housing pressure vessels

Side Entry Design
Available in 600 psi pressure rating
8 INCH frp membrane housings Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

8 INCH frp membrane housings Key Features:
Operating Temp Range: -10°C ---49°C
Internal permeate port not to exceed 125PSI(0.88 MPa)
Operating pH Range: 3 11
Cleaning pH Range: 2 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
Multi-ports option
White color is as standard. Customized colors are also available.
ASME Code stamp available upon request
Apr-10-20
 
FRP MEMBRANE HOUSINGS W80S1200
8 INCH frp filter housings
Side Entry Design
Available in 1200 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON,BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
Specification
Winder frp membrane housing pressure vessels
Side Entry Design
Available in 1200 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON,BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
8 INCH frp membrane housings Key Features:
Operating Temp Range: -10°C ---49°C
Internal permeate port not to exceed 125PSI(0.88 MPa)
Operating pH Range: 3 11
Cleaning pH Range: 2 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
Multi-ports option
White color is as standard. Customized colors are also available.
ASME Code stamp available upon request
Quality Assurance
Hydro-static Leakage Test Pressure:
Standard:
100% test, not sampling
? 100,000 times cycle test
? Burst test with 6 times of its operating pressure
? 100% QA test with 1.5x design hydraulic pressure.
Apr-10-20
 
FRP MEMBRANE HOUSINGS W80S1500
Winder frp membrane housing pressure vessels
Side Entry Design
Available in 1500 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY ,CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF
Specification
Winder frp membrane housing pressure vessels

Side Entry Design
Available in 1500 psi pressure rating
Accommodates standard make 8" Membrane Element
Element length: 40" x (1-8)
Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY ,CSM, VONTRON, BDX, etc.
Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

8 INCH frp membrane housings Key Features:
Operating Temp Range: -10°C ---49°C
Internal permeate port not to exceed 125PSI(0.88MPa)
Operating pH Range: 3 11
Cleaning pH Range: 2 12 (less than 30 minutes)
Mirror inner wall and brightly surface.
Multi-ports option
White color is as standard. Customized colors are also available.
ASME Code stamp available upon request
8 INCH frp membrane housing price
Quality Assurance
Hydro-static Leakage Test Pressure:
Standard:
100% test, not sampling
? 100,000 times cycle test
? Burst test with 6 times of its operating pressure
? 100% QA test with 1.5x design hydraulic pressure.
ASME: 1.1x Design Pressure
? 100% QA inspection and cleaning before final
packaging and delivery to customers.
? Submitted for NSF standard 61

Applications:
Winder FRP membrane housing pressure vessels are widely used for industrial waste water treatment, seawater desalination, brackish water desalination, RO system for electronics, electric power, food & beverage, metallurgy, chemical, pharmaceutical and other fields.
Sep-09-20
 
W80S300/450 FRP MEMBRANE HOUSINGS
Winder frp membrane housings-2019 design
Hydrostatic Water Leakage Test-1.4 Times of Operation Pressure
Low pressure frp membrane housing-Winder series with similar structure

Available in 150,300.450 psi pressure rating

Accommodates standard make 8" Membrane Element

Element length: 40" x (1-8)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

Winder frp membrane housing pressure vessels

Low pressure frp membrane housing-Winder series with similar structure

Available in 150,300.450 psi pressure rating

Hydrostatic Water Leakage Test-1.4times of operation pressure

Model:W80S1000-5(3" side portÃ??4 ports)
Side Entry Design

Available in 300 psi pressure rating

Accommodates standard make 8" Membrane Element

Element length: 40" x (1-8)

Applicable to: DOW, HYDRANAUTICS, OSMONICS, KOCH, TORAY, CSM, VONTRON, BDX, etc.

Standard: ASME RP, CE, ISO9001, ISO14001, UL/NSF

Key Features:

Operating Temp Range: -10�°C ---49�°C

Internal permeate port not to exceed 125PSI(0.88MPa)

Operating pH Range: 3 â?? 11

Cleaning pH Range: 2 â?? 12 (less than 30 minutes)

Mirror inner wall and brightly surface.

Multi-ports option

White color is as standard. Customized colors are also available.

ASME Code stamp available upon request

Differences of mebrane housings Winder 2012,2019, Rohone aluminium cap and ABS cap design:


Quality Assurance

Hydro-static Leakage Test Pressure:

industrial frp membrane housings Standard:

100% test, not sampling

Ã?? 100,000 times cycle test

Ã?? Burst test with 6 times of its operating pressure

Ã?? 100% QA test with 1.5x design hydraulic pressure.

ASME: 1.1x Design Pressure

Ã?? 100% QA inspection and cleaning before final

packaging and delivery to customers.

Submitted for NSF standard 61

Verification Status