Physical Parameters
Bus signal: compliant with IEC61158-2 physical layer standard
Bus power supply: 9 ~ 32V
Operating temperature: -40 ~ 85°C
Static current: â?¤14mA
Humidity range: 5% ~ 95%,non-dew
Mechanism size: diameter 66mm(can be customized)
Supportive MODBUS Communication Parameters
Address: 1 ~ 255
Baud rate: 9600 / 19200 / 15625 / 31250 /62500 / 125000 bps
Data bit: 7 / 8 bits
Calibration: odd / even calibration
Stop bit: 1 / 2 bits
CRC calibration: low byte ahead / high byte ahead
Data format: support various data formats
Supportive MODBUS Function Code
Function Code 1: read loop status
Function Code 2: read discrete input status
Function Code 3: read keeping register value
Function Code 4: read input register value
Function Code 6: write loop
Function Code 16:write multiple register values
Modbus-DP built-in module realizes the connection from Modbus RTU device to PROFIBUS DP network .It realizes the conversion function from MODBUS Protocol to PROFIBUS DP Protocol. Only by simply operating Modbus configuration tool, the users can realize connection from Modbus RTU device to PROFIBUS DP network. M0306 module works with DIP16 2.54mm standard interface, 3.3 V power supply, Modbus communication indicating light to quick diagnosis the device status. It uses simple convenience Combining with the features of high reliability and high flexibility, M0306 module is an ideal choice for user to develop OEM devices with PROFIBUS DP protocol.
Physical Parameters Bus signal: compliant with IEC61158-2 physical layer standard Bus power supply: 9 ~ 32V Operating temperature: -40 ~ 85°C Static current: â?¤14mA Humidity range: 5% ~ 95%,non-dew Mechanism size: diameter 66mm(can be customized) Supportive MODBUS Communication Parameters Address: 1 ~ 255 Baud rate: 9600 / 19200 / 15625 / 31250 /62500 / 125000 bps Data bit: 7 / 8 bits Calibration: odd / even calibration Stop bit: 1 / 2 bits CRC calibration: low byte ahead / high byte ahead Data format: support various data formats Supportive MODBUS Function Code Function Code 1: read loop status Function Code 2: read discrete input status Function Code 3: read keeping register value Function Code 4: read input register value Function Code 6: write loop Function Code 16:write multiple register values
Product Overview M0310 module makes it possible to convert Modbus RTU protocol directly to HART protocol. Using M0310 module, the difficulty of development can be reduced and the upgrade of Modbus RTU device can be easily achieved. Only by simply configuration, the users can realize conversion from Modbus RTU protocol to HART protocol. M0310 module is provided with two LED indicating lights, used to indicate the current working status. Features Comply with HART PROTOCOL standard V7.0 HART slave station and Modbus master station form Support 1 Modbus RTU slave device Support 6 device variables,4 dynamic variables Configured by HART interface Write-protection of users data Support high/low current transfinite alarm TTL Modbus interface LED power and communication indicator
Product Overview M0313 module makes it possible to convert Modbus RTU protocol directly to FF H1 protocol. Using M0313 module, the difficulty of development can be reduced and the upgrade of Modbus RTU device can be easily achieved. Only by simply configuration, the users can realize conversion from Modbus RTU protocol to FF protocol. M0313 module is provided with two LED indicating lights, used to indicate the current working status. Features Support 1 Modbus RTU slave device 1 RES function block complying to FF specification 1 Modbus transducer block 4 PID function blocks complying to FF specification 4 for each AI,AO,DI,DO function block complying to FF specification, each function block supports 8 channels Modbus RTU device upgrading LED working status indicator
The M160T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 10Mhz high speed pulse counter, 8 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 8 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure itâ??s reliable. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system. 1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog; 2. Power supply 12~36VDC with over voltage and phase-reversal protection; 3. Supports TCP Server, TCP Client, Modbus TCP, MQTT Protocols; 4. DO1 support PWM output; 5. Management and configuration via LAN connection configuration software for easy operation and maintenance; 6. 8 optical isolated digital input, supports max. 700khz high speed pulse counter; 7. 8 digital output or relay output, supports 10Hz~300KHz high speed pulse output; 8. 8 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC; 9. High sampling frequency and special filtering strategy to ensure reliability; 10.1 RS485 Serial port, supports Modbus RTU Master or Slave, can extend I/O modules; 11.Supports register mapping function and extend I/O inquiry strategy; 12.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost; 13.LED instructions work status, with reset button to reset, easy on-site installation and commissioning; 14.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field; 13.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
4DI+4DO Remote IO Module Item No.: M110 M110 Industrial Remote I/O Module provides 4 optical-isolated digital inputs, supports Max. 700KHz high speed pulse counter, 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. T Version: 1*RJ45+1RS485+4DI+4DO
The M160T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 10Mhz high speed pulse counter, 8 isolated 12bits analog inputs, supports 0~5V, 0~10V, 4~20mA, 0~20mA analog signal, 8 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure its reliable. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
Supplier: Embedded ethernet IP interface module, embedded modbus tcp interface
Supplier: PLC programming cable, siemens I/O module, siemens profibus connectors etc accessories, siemens PLC, siemens CPU, sensor