Good lighting is the main feature of contemporary architecture. Many large glass curtain wall frame structures, such as shopping malls and office buildings, cannot be installed with conventional radiators due to the small number of solid walls. Floor-mounted radiators are developed for this situation.
The forced convection floor embedded convector is provided with a cross-flow fan on the basis of the natural convection floor embedded convector, so that the limited heat dissipating component placed in the floor groove space outputs higher heat in the low noise operation environment, thereby achieving Heating requirements.
Compared to the natural convection floor convector, the forced convection floor embedded convector can release more powerful heat, with fast heat dissipation and low energy consumption. Suitable for use in a wide range of space heating.
Forced single-heat floor in-line convectors can be arranged in units and continuously.
HYDQQ-Floor convector with fan(Forced floor convector):
Low electrical energy consumption.
High heating performance than office heater without fan.
German cross-flow fan with more than 50000 hours normal life time.
And it can still work beyond the time limit to produce still low noise.
Pls contact us for more information of the Floor Convectors.
Contact Person: Bruce Zhang
Mobile:+86 18625772865
"Ultrasonic heating and cooling energy meters to measure flow and energy in hydronic heating or refrigerant circuits. Available as heat, cooling energy, or combined heat/cooling energy meters Separate acquisition of heating or cooling energy by the combined heat/cooling energy meters, with automatic changeover Non-wearing due to non-moving parts Approved in accordance with EN 1434 and MID accuracy class 2 Any mounting position (horizontal or vertical), in return Measuring range of flow 1:100 as per EN 1434, 1:1,000 total range Choice of communication modules and power supplies Upstream or downstream setting paths are not required Optical interface as per EN 62056-21 Self-diagnostics"
1.Rated heating conditions A7/W35: outdoor air temp. 7 DB/6 WB, inlet water temp. 30, outlet water temp. 35 2.Rated cooling conditions A35W7: outdoor air temp. 35 DB/24 WB, inlet water temp. 12, outlet water temp. 3. Due to product improvement, the above data are subject to change without prior notice, please take the nameplate as standard.
INVONIC H is a modern and precise ultrasonic heat meter with ultrasonic flow sensor, that guarantees high measurement precision with a long term operating life regardless of its mounting position. The ultrasonic heat meter has a modular design, making possible to extend its functionality at any time by installing a communication module, changing the power supply option or replacing different temperature sensors. A robust brass body of flow sensor is available in a version with a threaded or flanged connection and may be used in the pressure scopes PN16 or PN25. The heat meter indications are entirely non-sensitive to external magnetic fields.
DC inverter Heat Pump, with the advanced DC inverter and EVI technology, can save you 80% heating cost compare with the traditional heating device like gas/fuel boiler and electrical heater. It heats fast and works perfectly with the radiator and floor heater to provide you a comfortable living environment even in very cold winter. It is one of the best heating devices available today. Main Features 1) Twin rotary compressor with inverter control DC inverter technology control the heat pump output according to the household's energy requirements. Low waste of the power! 2) Electronic Expansion Value allows the accurate refrigerant go through under different working conditions. 3) Intelligent controller and LCD displaying. 4) Safely operation with multi-protections. 5) Auto defrosting function. 6) Hydrophilic coating air exchanger and plate heat exchanger all available. OPTIONAL: Galvanized metal cabinet or stainless steel cabinet all available. R410a, R22, R407c refrigerant is available. DC Inverter Heat Pump Series Model YINI-080-BPCN Ambient temp.range Power supply Electric shock proof grade Class I Protection grade IPX4 Heating capacity/COP 17.5KW /3.40 Rated cooling capacity 14.5KW /2.82 Rated heating capacity 11.0KW /2.35 Compressor Scroll Rated refrigerating input power/current 5.16KW /23.5A Rated heating input power/current. 4.68KW /21.2A Max. working current Max. working current Max. working pressure of heat exchanger 4.2 Mpa Temperature range of refrigeration outlet Heat outlet temperature range Water yield 2500 L/h Refrigerant type/Weight R32-R410a/4.4 kg Noise 59 dB(A)
1) Working ambient range: -15ï½?45 2) Heating capacity: 9kw, 14kw, 18kw, 24kw, 34kw, 43kw, 85kw 3) COP up to 4.1 4) Refrigerant: R410a Airosd Thermal Technologyis a Professional Heat Pump Manufacturer Air Source Heating & Cooling Heat Pump ï¼?Normal Temperature Heat Pumpï¼?etc.
1) Working ambient range of Low Noise Air Source Heating Pump: -15ï½?45 2) Heating capacity: 9kw, 14kw, 18kw, 24kw, 34kw, 43kw, 85kw 3) COP up to 4.1 4) Refrigerant: R410a Airosd Thermal Technologyis a Professional Heat Pump Manufacturer for Building Reconstruction Heating Project, Swimming Pool, Primary School. We are specialized in research, production and sales of Air Source Heating Pump, providing a solution for the residential and commercial heat pump systems. Heat Pump Dryer is also supplied now. More information please view here.
1) Working ambient range: -15ï½?45 2) Heating capacity: 9kw, 14kw, 18kw, 24kw, 34kw, 43kw, 85kw 3) COP up to 4.1 4) Refrigerant: R410a Normal temperature heating & cooling heat pump MODEL FXK-009SMII FXK-013SMII FXK-018SMII FXK-024UII FXK-034UII FXK-042UII FXK-084UII Power 380V /3Nï½? /50Hz Working ambient range 15ï½?45 Rated heating capacity (A7W35) Heating capacity(A7W45) kW 9.00 13.60 18.20 24.30 34.40 42.70 84.60 Input power kW 2.18 3.42 4.44 5.90 8.75 10.84 21.36 COP / 4.12 3.98 4.10 4.12 3.93 3.94 3.96 Working current A 4.15 6.49 8.43 11.20 16.62 20.58 40.57 Rated cooling capaciy Cooling capacity kW 7.20 11.50 16.50 21.00 27.50 35.00 68.00 Input power kW 2.57 4.09 5.79 7.34 9.72 12.41 23.61 COP / 2.80 2.81 2.85 2.86 2.83 2.82 2.88 Max.working current A 8.00 12.00 14.00 18.00 26.00 30.00 60.00 Max.input power kW 5.80 7.00 7.80 11.50 14.50 16.50 33.00 Max.outlet water temp. 60.00 60.00 60.00 60.00 60.00 60.00 60.00 Compressor Brand / Panosonic / Rotary Copeland / scroll Copeland / scroll Copeland / scroll Copeland / scroll Copeland / scroll Copeland / Scroll QTY Pics 1.00 1.00 1.00 1.00 2.00 2.00 4.00 Refrigerant / R410a R410a R410a R410a R410a R410a R410a Air discharge / Side discharge Side discharge Side discharge Side discharge Side discharge Side discharge Side discharge Motor QTY / 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Heat exchanger Max pressure MPa 4.20 4.20 4.20 4.20 4.20 4.20 4.20 Suction/exhaust Max pressure MPa 4.20 4.20 4.20 4.20 4.20 4.20 4.20 Water side Max.Pressure MPa 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Waterproofing Grade / IPX4 IPX4 IPX4 IPX4 IPX5 IPX6 IPX7 Anti-electric shock / I I I I I I I Water flow m³/h 2.20 2.20 2.84 3.61 4.73 6.02 11.70 Water side pressure reduce kPa â?¤40 â?¤40 â?¤40 â?¤50 â?¤50 â?¤60 â?¤70 Noise dB(A) â?¤58 â?¤60 â?¤60 â?¤65 â?¤65 â?¤68 â?¤70 Net Size (L*W*H) mm 1030Ã?380Ã?1335 1030Ã?380Ã?1335 1030Ã?380Ã?1335 830Ã?790Ã?1070 1500Ã?690Ã?1070 1500Ã?690Ã?1270 2100Ã?1100Ã?2000 Weight kg 80 90 130 250 350 380 880 1. Rated heating conditions A7/W35: outdoor air temp. 7 DB/6 WB, inlet water temp. 30, outlet water temp. 35. 2. Rated cooling conditions A35W7 : outdoor air temp. 35 DB/24 WB, inlet water temp. 12, outlet water temp. 7. An Air Source Heating Pump can provide High Efficiency heating and Cooling for your home. When properly installed, an Low Noise Heating And Cooling Heat Pump can deliver one-and-a-half to three times more heat energy to a home than the electrical energy it consumes. More information please view here
China Air Source Cooling Heating Pump, High Efficiency Air Source Heating Pump, Factory 1) Working ambient range: -15ï½?45 2) Heating capacity: 9kw, 14kw, 18kw, 24kw, 34kw, 43kw, 85kw 3) COP up to 4.1 4) Refrigerant: R410a Airosd Thermal Technologyis a Professional Heat Pump Manufacturer for Building Reconstruction Heating Project, Swimming Pool, Primary School. We are specialized in research, production and sales of Air Source Heating Pump, providing a solution for the residential and commercial heat pump systems. Heat Pump Dryer is also supplied now. More information please view here.
FXK-009SMII 9kw normal temperature heating & cooling heat pump cNormal temperature heating & cooling heat pump MODEL FXK-009SMII FXK-013SMII FXK-018SMII FXK-024UII FXK-034UII FXK-042UII FXK-084UII Power 380V /3Nï½? /50Hz Working ambient range -15ï½?45 Rated heating capacity (A7W35) Heating capacity(A7W45) kW 9.00 13.60 18.20 24.30 34.40 42.70 84.60 Input power kW 2.18 3.42 4.44 5.90 8.75 10.84 21.36 COP / 4.12 3.98 4.10 4.12 3.93 3.94 3.96 Working current A 4.15 6.49 8.43 11.20 16.62 20.58 40.57 Rated cooling capaciy Cooling capacity kW 7.20 11.50 16.50 21.00 27.50 35.00 68.00 Input power kW 2.57 4.09 5.79 7.34 9.72 12.41 23.61 COP / 2.80 2.81 2.85 2.86 2.83 2.82 2.88 Max.working current A 8.00 12.00 14.00 18.00 26.00 30.00 60.00 Max.input power kW 5.80 7.00 7.80 11.50 14.50 16.50 33.00 Max.outlet water temp. 60.00 60.00 60.00 60.00 60.00 60.00 60.00 Compressor Brand / Panosonic / Rotary Copeland / scroll Copeland / scroll Copeland / scroll Copeland / scroll Copeland / scroll Copeland / Scroll QTY Pics 1.00 1.00 1.00 1.00 2.00 2.00 4.00 Refrigerant / R410a R410a R410a R410a R410a R410a R410a Air discharge / Side discharge Side discharge Side discharge Side discharge Side discharge Side discharge Side discharge Motor QTY / 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Heat exchanger Max pressure MPa 4.20 4.20 4.20 4.20 4.20 4.20 4.20 Suction/exhaust Max pressure MPa 4.20 4.20 4.20 4.20 4.20 4.20 4.20 Water side Max.Pressure MPa 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Waterproofing Grade / IPX4 IPX4 IPX4 IPX4 IPX5 IPX6 IPX7 Anti-electric shock / I I I I I I I Water flow m³/h 2.20 2.20 2.84 3.61 4.73 6.02 11.70 Water side pressure reduce kPa â?¤40 â?¤40 â?¤40 â?¤50 â?¤50 â?¤60 â?¤70 Noise dB(A) â?¤58 â?¤60 â?¤60 â?¤65 â?¤65 â?¤68 â?¤70 Net Size (L*W*H) mm 1030Ã?380Ã?1335 1030Ã?380Ã?1335 1030Ã?380Ã?1335 830Ã?790Ã?1070 1500Ã?690Ã?1070 1500Ã?690Ã?1270 2100Ã?1100Ã?2000 Weight kg 80 90 130 250 350 380 880 1. Rated heating conditions A7/W35: outdoor air temp. 7 DB/6 WB, inlet water temp. 30, outlet water temp. 35. 2. Rated cooling conditions A35W7 : outdoor air temp. 35 DB/24 WB, inlet water temp. 12, outlet water temp. 7. Heat Pumps work by moving heat from one place to another using energy to perform this task. They are used for heating indoor buildings, but they also have outdoors applications such as warming up Swimming Pools. If you are interested in our Water and Ground Source Heat Pump Dryer, Water Source Heat Pump 17KW, you can email or call us at any time. More information please view here.