Scn series economical counter
Feature
1.Use scm function, convenient to operate
2.8 position counter display
3.Relay output action:(r, n, c, f)4 initialization output mode
4.Main fold relay initialization alarm output
5.Backup data for power fail, the data will be 10 years after power fail
6.Many models, suitable for each kinds of industrial equipment
Model and parameter
Counting signalInput impedanceMore than 100kª+
Input levelH more than 5v; l less than 1v
Max. Input50v
StepDescend edge
Relay
OutputOutput modeJ1 (first section)R, n, c, f
Delay range0s-99.99s
Contact burden250va, 3a
Power supplyAc90v-250v ía10%(50)hz
Anti-interferencePower:ía3000v input:ía2500v
Ambinet0ípc to +50ípc
Storage temperature-20ípc to +70ípc
Withstand impedanceMin 100mª+
Counting speed (4 class set in total)20cps, 200cps, 3000cps, <10000cps
Carton
Tcn series counter with following details.
1. Backup data for power fail
2. 6 or 4 position digit counter
3. Precision measuring and easy-read, high anti-interference
4. Output alarm with relay
Model and parameter
Counting signal Input impedance More than 100kª+
Input level H more than 5v; l less than 2v
Max. Input 50v
Step Descend edge
Relay output Output mode R, n, c, f
Output cycle 0-99.9s
Contact burden 250vac/3a
Power supply Ac90v-260v (50hz)
Anti-interference Iec801 3g
Ambinet temperature 0 to +50ípc
Storage temperature -20ípc to +70ípc
Withstand impedance Min100mª+
Counting speed (5 class forset) 20cps, 200cps, 3000c ps, 10000cps
Carton
Multi-function counter with following details.
Feature
1. Red led display
2. Backup data for power fail
3. Multi-function intelligent meter, used as counter frequency meter,
Speed meter etc. By pressing four key(32 type)
4. Main fold relay output fashion
Model and parameter
1.Counting signal impedance more than 100kª+
Input level h more than 5v; l less than 2v
Max. Input 50v
Step descend edge
2.Contact content ac220v 3a; dc24v 5a (resistive load )
3.Noise elimination ratio more than nmr 40db (50hz/60hz) ía10%
4.Over range indication digital flashing
5.Operation temperature 0-50ípc, <85%rh
6.Power voltage ac110/220v 3a; (50hz/60hz) ía10%
7.Consumption about 3av
8.Insulation strength dc500v 20mª+
9.Insulation strength ac2000v 1min
Carton
Cd-x08 series 3 digital temperature controller
Feature
1. New algorithm using fuzzy logical pid control
2. Six alarm mode setting freely
3. Tc input, rtd input, voltage input, ampere input
4. Relay output, voltage output, ampere output
5. 3 digit led display
Model and parameter
1.How to select input type
Rtd Pt100(0-499.9ípc) No need custom-mode; free exchange the input way
Tc K(0-600ípc)
R(0-1600ípc), s(0-1600ípc)ú¼bú¿0-1800ípcú¬ú¼eú¿0-1000ípcú¬ú¼nú¿0-1200ípcú¬ú¼jú¿0-800ípcú¬ú¼tú¿0-400ípcú¬ Need custom-mode
2.Technical parameters
Measuring accuracy Less ía0.5%f.Síal dig
Control mode On/off control, pid direct action, pid reverse action
Control accuracy ía1ípc
Control output Relay output, voltage output
0-10madc output, 4-20madc output
Relay contact burden 3a/250vac
Power 90-250vac 60hz
Anti-interference Iec 3g
Carton
Cd-xoo series 4 digital temperature controller with following details.
Feature
1. New algorithm using fuzzy logical pid control
2. Six alarm mode setting freely
3. Tc input, rtd input, voltage input, ampere input
4. Relay output, voltage output, ampere output
Model and parameter
1.How to select the type
Standard signal 0-5vdc input, 1-5vdc input
0-10madc input
4-20madc input Level input is 0-50dvc
Rtd Pt100 (0-499.9íµ), gu50(0-99.9íµ) No need custom-made; freee
Exchange the input way
Tc K(0-600íµ), j(0-800íµ), t(0-400íµ
R(0-1600íµ), s(0-1600íµ), b(0-1800íµ), e(0-1000íµ), n(0-1200íµ), l Need custom-mode
2.Technical parameters
Measuring accuracy Less ía0.5%f.Síal dig
Control mode On/off control, pid direct action, pid reverse action
Control accuracy ía1ípc
Control output Relay output, voltage output
0-10madc output, 4-20madc output
Relay contact burden 3a/250vac
Power 90-250vac 50hz/ 60hz
Anti-interference Iec 3g
Carton