Power output : 15kw
Inverter frequency : 40khz
X-ray tube : xd56-5 17/130
Small focus: 0.3 large focus: 0.6
Thermal capacity: 212kj (300 khu)
The speed of the rotary anode: 3000rpm
Tube voltage : 40~125kv
Tube current : 200ma
Mas : 0.4~360mas
Bucky grid : grid density 103l/inch; grid ratio:10:1
Focus distance:150cm stationary
18"íß18"(import)
Power supply : 220vía10% 50hz, capacity: í²16kw
Operation method : graphic remote-control lcd touch screen
And wireless remote-control exposure
(optional: control box of graphic remote-control
Lcd touch screen)
Specifications
Fluoroscopic capacity
Max rated capacity : tube current 4ma, tube voltage 110kv
Automatic fluoroscopy : tube voltage:40kví½110kv adjust
Automatically
Tube current : 0.3maí½4ma set manually
Manual fluoroscopy : continuous tube voltage:40kví½110kv
Continuous tube current : 0.3maí½4ma
Pulse fluoroscopy : continuous tube voltage 40kví½110kv
Continuous tube current 4.1maí½8ma
Photography capacity
Max rated capacity : 3.5 kw
Tube voltage and cur-
Rent combination : 40kví½49kv 1 í½125 mas
50kví½59kv 1 í½110 mas
60kví½69kv 1 í½90 mas
70kví½79kv 1 í½80 mas
80kví½89kv 1 í½71 mas
90kví½99kv 1 í½63 mas
100kví½110kv 1 í½40 mas
Plateholder size : 200mmíß250mm(8ísíß10ís)or
250mmíß300mmú¿10ísíß12ísú¬
X-ray tube
X-ray tube special for high frequency
Fixed anode
Dual-focus: large focus: 1.5, small focus: 0.6
Inverter frequency: 40khz
Thermal capacity: 30kj (40hu)
Videosystem
Image intensifier : image intensifier made by toshiba (9ísíó
6ísíó4.5ís)
Ccd vidicon : ultra low-light ccd camera imported from japan
Monitor : horizontal 1000 lines and vertical 800 lines,
Bandwidth : 12.5mhz,
Image/sec : 75
Ccu(central control) : recursive filter: k=8, 8 images storage,
Image upright, image overturnú¼positive &
Negative imageú+lih(last image freeze, and
Osdú¿monitor displayú¬
Structure
Directive wheel : ía90íprevolutionú¼can freely change the moving
Direction of the unit.
Ascending & descend-
Ing range of pillar : í²400mm
C-arm : forward and backward movement: 200mm
Revolution around horizontal axis: ía180íp
Revolution around vertical axis : ía15íp
Slip on orbit: 120íp(+90ípí½ -30íp)
Packing details : 2440mmíß1100mmíß1420mm
N.W. 300kgs g.W.400kgs
Packing details : 2440mmíß1100mmíß1420mm
N.W. 300kgs g.W.400kgs
High frequency x-ray machine Max rated capacity of photography íí 25kw
Main inverter frequency íí 40khz
X-ray tube Dual-focus Small focus:0.6 large focus: 1.3
Rotating anode speed 3000rpm
Maximum tube current íí 200ma
Tube voltage íí 40-125kv
Mas íí 0.4-360mas
Bed transverse movement range distance: a110mm
Portrait movement of photography frame and track spot film: ²720mm
Photography dimension of whole film: 8¦10¦~14¦ 17¦
Spot film division: whole film, 2-division film, 3-division film, 4-division film
Method to control bed: remote control, bed-control, soft boot and stay of frequency conversion
Beam applicator: electrodynamics multi-pin
Bed-applied fixed bucky grid: grid density: 103l/inch
Grid ratio: 10:1, focus distance: 120cm, 15¦ 18¦
Digital tv system
Ega: 9¦ toshiba, high resolution ccd (digital camera); imported low-light 0.47 mega pilexs
Monitor: 14¦ medical high definition monitor, horizontal central resolution 1000 thread, edge 800
Thread, video wideband 12.5mhz, 50bit, 25 pictures per second
Picture-process system: high definition and non-interlaced output, 8-grade noise reduction, 7
Pictures in storage, lih, mirror image rotation in vertical and horizontal, positive-negative
Image; osd (monitor display)
Category item content
Fluoroscopy capacity perspective max rated capacity tube current 8 ma , tube voltage 120 kv
Automatic fluoroscopy tube voltage: 40kví½120kv , adjust automatically
Tube current :0.3ma~4ma .Adjust automatically
Manual fluoroscopy tube voltage 40 kv, 110kv, continuous
Tube current :0.3ma~~4ma continuous
Pulse frequencetube voltage 40kví½120kv, continuous
Tube current : 4.1maí½8ma continuous
X ray tubex ray tube special for high frequency bifocus rotary anode x-ray tube: large focus:1.5, s mall focus :0.3; high frequency power supply , main inverter frequency :60khz, thermal capacity :34kj(47khu)
Imaging system image intensifier Toshiba 9 "image intensifier (230mm)
Video camera ultra-low-light digital camera for medical a / d digits 12bit