Technical Specification Chart
Parameter 1 - Phase 2 - Phase 3 - Phase
Unbalanced
Air Cooled 3 - Phase
Balanced
Oil Cooled 3 - Phase
Unbalanced
Oil Cooled Energy
Conserved
Lighting Load Centralized
Stabilizer for offices & residence
Rating (KVA) 1 - 20 0.5 - 20 3 - 100 3 - 200 3 - 250 3 - 500 3 - 500
I/P Voltage range (V) 170 - 270
195 - 265 340 - 480 240 - 480
340 - 480
360 - 460 310 - 480
340 - 460
360 - 460 340 - 480
360 - 460 310 - 480
340 - 480
360 - 460 310 - 480
340 - 480
360 - 460
O/P Voltage(normal) 230 V 415 V 415 V 415 V 415 V 208 V LN 220 V / 230 V
LN
Alternate
O/P setting 220 V /
240 V 380 V / 400 LL 220 V LN 220 V / 230 V
LN
O/P V regulation ¦ 1% of nominal output voltage
O/P V Indications Digital voltmeter, accuracy 1% of FS ¦ 1 digit
LED Indications Front panel LED Indicators, Input ON, output ON, Input high / Low, output High / Low trip
Under over voltage trip Electronic cutoff circuit with graded time delay set @ + 5% / -10% of nominal voltage
Over Load cut off Electronic cutoff circuit with graded time delay set @ 110% of rated full load current
Short circuit protection HRC fuse / MCB at input
Single phasing
prevention Not applicable Provide Individual phase cut off only
Service bypass Not provided Provide upto 100 Kva. 3 phase Individual phase bypass provided upto 50 kVA 3-ph
Resetting mode Automatic restart with time delay mode of 15 sec. (optional)
Technical Specification Chart:
Parameter
1 - Phase
2 - Phase
3 - Phase
Unbalanced
Air Cooled
3 - Phase
Balanced
Oil Cooled
3 - Phase
Unbalanced
Oil Cooled
Energy
Conserved
Lighting Load
Centralized
Stabilizer for
offices &
residence
Rating (KVA)
1 - 20
0.5 - 20
3 - 100
3 - 200
3 - 250
3 - 500
3 - 500
I/P Voltage
range (V)
170 - 270
195 - 265
340 - 480
240 - 480
340 - 480
360 - 460
310 - 480
340 - 460
360 - 460
340 - 480
360 - 460
310 - 480
340 - 480
360 - 460
310 - 480
340 - 480
360 - 460
O/P Voltage
(normal)
230 V
415 V
415 V
415 V
415 V
208 V LN
220 V / 230 V
LN
Alternate
O/P setting
220 V /
240 V
380 V / 400 LL
220 V LN
220 V / 230 V
LN
O/P V
regulation
± 1% of nominal output voltage
O/P V
Indications
Digital voltmeter, accuracy 1% of FS ± 1 digit
LED
Indications
Front panel LED Indicators, Input ON, output ON, Input high / Low, output High / Low trip
Under over
voltage trip
Electronic cutoff circuit with graded time delay set @ + 5% / -10% of nominal voltage
Over Load
cut off
Electronic cutoff circuit with graded time delay set @ 110% of rated full load current
Short circuit
protection
HRC fuse / MCB at input
Single phasing
prevention
Not applicable
Provide
Individual phase cutoff only
Service
bypass
Not provided
Provide upto 100 Kva. 3 phase
Individual phase bypass
provided up to 50 kVA 3-ph
Resetting
mode
Automatic restart with time delay mode of 15 sec. (optional).
Servo stabilizer.
Automatic on and off of motor/pump.
Controls motor running & water level in the tank, dual purpose.
No supervision required.
The microprocessor based electronic timer ensures motor will be running for very less time.
Collects even the little water effectively.
Increased life of motor.
Maintenance free.
Cost cut down in power usage or it utilizes less power
Low voltage protection.
Automatic overflow protection.
Sump monitoring system, mainly for corporation/lorry water pumping.
Bypass feature in case of any issue or manual operation.
Can be customizable for industries to suit their application.
Can be used for water and any other liquids.
Very useful for flat builders, promoters, flats, industries & individual houses.
In simple the following are the major advantages :-
Fully automatic , no tension of switching motor on & off
Effective water pumping technique.
No overflows.
Low power consumption.
Increased motor life.
24 hours of cyclic operation
Very useful in summer season and water scarcity location, because this will pump even the little water collected inside the bore very frequently.
Save water; save power; save environment