Includes:
4 x 2 x 0.585mm BC conductor
F-PE insulation
Twisted pair screen
First AL Mylar shield
Overall braid screen
Rip cord
PVC sheath
Conductor:
Material: solid bare copper
Number of pairs: 4 pairs
AWG: 23
Conductor diameter: 0.585 0.003mm
Insulation:
Material: F-PE
Diameter: 1.35 0.005mm
Average thickness: 0.4325mm
Minimum point thickness: 0.4320mm
Twisted pair screen: AL foil (25%)
First screen: AL foil (25%)
Overall screen: TC (96/0.10mm) and braid (braid density: 40%)
Jacket rid cord: optional
Sheath:
Material: PVC or LSOH
Nominal diameter: 9.0 0.2mm
Average thickness: 0.65mm
Minimum point thickness: 0.645mm
Operating temperature: -20 to 75ípC
Minimum bend radius (install): (OD) 8mm
Flame test: CMX, CM, CMR and IEC60332-1
Reference standard: TIA/EIA568B and IEC/ISO11801.
Includes:
4 x 2 x 0.575mm BC conductor
F-PE insulation
Twisted pair screen
First aluminum mylar shield
Overall braid screen
Rip cord
PVC sheath
Conductor:
Material: solid bare copper
Number of pairs: 4 pairs
AWG: 23
Conductor diameter: 0.575 í0.003mm
Insulation:
Material: F-PE
Diameter: 1.35 í0.005mm
Average thickness: 0.3875mm
Minimum point thickness: 0.3870mm
Twisted pair screen: aluminum foil (25%)
First screen: aluminum foil (25%)
Overall screen: TC (96/0.10mm) and braid (braid density: 40%)
Jacket rid cord: optional
Sheath:
Material: PVC or LSOH
Nominal diameter: 9.0 í0.2mm
Average thickness: 0.65mm
Minimum point thickness: 0.645mm
Operating temperature: -20 to 75ípC
Minimum bend radius (install): (OD) 8mm
Flame test: CMX, CM, CMR and IEC60332-1
Reference standards: TIA/EIA568B and IEC/ISO1180.
Conductor:
Material: solid bare copper
Number of pairs: 4 pairs
AWG: 24
Conductor diameter: 0.5750.003mm
Insulation:
Material: HDPE and FRPE
Diameter: 1.0240.005mm
Average thickness: 0.2245mm
Minimum point thickness: 0.2240mm
Divider: PP
Jacket rid cord: optional
Sheath:
Material: PVC or LSOH
Nominal diameter: 6.50.2mm
Average thickness: 0.6mm
Minimum point thickness: 0.595mm
Includes:
BC conductor
PE insulation
Divider
Rip cord
PVC sheath
Operating temperature: -20 to 75ípC
Minimum bend radius (install): (OD) 8mm
Flame test: CMX, CM, CMR and IEC60332-1
Reference standard: TIA/EIA568B and IEC/ISO11801.
Includes:
BC conductor
PE insulation
Messenger
Inner sheath
Overall sheath
Conductor:
Material: solid bare copper
Number of pairs: 4 pairs
AWG: 24
Conductor diameter: 0.50 ¦0.003mm
Insulation:
Material: HDPE and FRPE
Diameter: 0.924 ¦0.005mm
Average thickness: 0.212mm
Minimum point thickness: 0.2095mm
Messenger: +1.16mm steel wire
Inner cable sheath:
Material: PVC LSOH
Nominal diameter: 5.0 ¦0.2mm
Average thickness: 0.55mm
Minimum point thickness: 0.54mm
Outer cable sheath:
Material: PE
Nominal diameter: 7.0 ¦0.2mm
Average thickness: 1.0mm
Minimum point thickness: 0.95mm
Messenger sheath:
Material: PE
Nominal diameter: 3.2 ¦0.1mm
Average thickness: 1.0mm
Minimum point thickness: 0.95mm
Operating temperature: -20 to 75¦C
Minimum bend radius (install): (OD) 8mm
Flame test: CMX, CM, CMR and IEC60332-1
Reference standard: TIA/EIA568B and IEC/ISO11801.
Includes:
25 x 2 x 0.50mm BC conductor
PE insulation
Separator
Cable tie
Rip cord
PVC sheath
Conductor:
Material: solid bare copper
Number of pairs: 25 pairs
AWG: 24
Diameter: 0.50 0.003mm
Insulation:
Material: HDPE and FRPE
Diameter: 0.924 0.005mm
Average thickness: 0.212mm
Minimum point thickness: 0.2095mm
Separator: PPE
Cable tie: PE
Jacket rip cord: optional
Sheath:
Material: PVC or PE
Nominal diameter: 12.5 0.2mm
Average thickness: 1.0mm
Minimum point thickness: 0.995mm
Operating temperature: -20 to 75ípC
Minimum bend radius (install): (OD) 8mm
Flame test: CMX, CM, CMR and IEC60332-1
Reference standard: TIA/EIA568B and IEC/ISO1180.