Technical Specification:
Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite, leukocytes, glucose, specific gravity, and pH
Test wavelength: 525nm, 572nm, 610nm, 660nm
Test principle: Reflectance Photometer
Suitable strips: DIRUI H8 and H10 urinalysis strips
Test throughput: 120 strips/h or 60 strips/h optional
Data memory: 1000 patient results
Computer interface: RS-232 port
Display: 128Ãí¬32 dot-matrix LCD
Language: Chinese and English
Power supply: 100~240VAC, 50Hz/60Hz
Power: 25VA
Printer: Built-in thermal printer
Dimensions: 270mmÃí¬180mmÃí¬100mm
Weight: 1.15kg
Technical specification:
Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite,leukocytes, glucose, specific gravity, pH and VC
Test wavelength: 525nm, 572nm, 610nm, 660nm
Test principle: Reflectande Photometer
Suitable strips: DIRUI H8, H10 and H11 urinalysis strips
Test throughput:120 strips/h or 60 strips/h optional
Data memory: 1000 patient results
Computer interface: RS-232 port; parell printer port
Display: 240Ãí¬64 dot-matrix LCD
Language: Chinese and English
Power supply: 100~240VAC, 50Hz/60Hz
Power: 40VA
Dimensions: 376mmÃí¬316mmÃí¬170mm
Weight: 3.6kg
Technical Specification:
Test items: urobilinogen, bilirubin, ketone, blood, protein, nitrite, leukocytes, glucose, specific gravity, pH and VC
Test wavelength: 525nm, 572nm, 610nm, 660nm
Test principle: Reflectance Photometer
Suitable strips: DIRUI H8, H10 and H11 urinalysis strips
Test throughput: 514strips/h
Data memory: 2000 patient results
Computer interface: RS-232 port; parell printer port
Display: 240Ãí¬64 dot-matrix LCD
Language: Chinese and English
Power supply: 100~240VAC, 50Hz/60Hz
Power: 40VA
Printer: Built-in thermal printer
Dimensions: 380mmÃí¬378mmÃí¬275mm
Weight: 6.5kg
Specification:
Wavelength range:340nmíó405nmíó450nmíó492nmíó505nmíó546nmíó578nmíó630nm available
Wavelength Accuracy: Âí+2nm
Spectrum bandwidth: 6-12nm
Absorbancy:-0.3í½3.0 ABS
Resolution: Display with 1m ABS , internal with 0.1m ABS
Linearity: less than 0.5% within 1ABS
Stability: 20 minutes for warm-up and then í_3mABS/hour
Measure repeatability : 2m ABS
Measurement time: 0í½999s programmable
Delay time: 0í½999s programmable
Memory: 200 testing programs , 3000 testing results
Sampling: 100í½9999ª¦l programmable
Microflowcell volume :32ª¦l
Cross-contamination: í_1%
Differentiation rate: í_1%
Absorbancy repeatability: í_1%
Display: Matrix LCD
Power consumption: 85w
Dimension:462X418X232mm
Weight:6.5KG
Technical Specification
WBC HGB
LYM% LYM%
MON% MON%
GRA% GRA%
HCT RBC
MCH MCV
RDW-CV MCHC
RDW-SD PLT
PCT MPV
PDW P-LCR
RBC histogram
WBC histogram
PLT histogram
Calibration: manual calibration, automatic calibration,fresh blood calibration
Cross contamination rate: WBC,RBC,HGB<0.5%, PLT<1%
Testing diameter: 100um (WBC), 70um (RBC, PLT)
Aperture parameter: 3-Part Differential leukocytecount, 20parameters and 3 histograms.
Sample consumption: Whole blood 13uL, prediluted20uL
Counting mode: Whole blood and prediluted
Throughput: 60samples/hr
Display: 320+ù240 resolution, 5.6 inch LCD display
Reagent: DIRUI reagent
Power supply: 100~244VAC 50/60Hz
Power: 180W
Communication: RS-232C serial port
Environment requirement: ambient temperature 0-40, relative humidity 85%
Dimension: 448(L) +ù390 (W) +ù455(H)
Weight: 19kg