Electronic single-phase power meter
Reference voltage 220v
Voltage reference un-1 .2 0.7ub
Current specifications 5-30a
Reference frequency 50hz
Grading accuracy + level
Starting current 0.005ib = 0.025a
Voltage power lines
Communication transmission distance no
Environmental conditions -25f¬f+70f¬
Relative humidity -_85%
Automatic relay depth
Data transmission speed
Center frequency
Dimensions
Reference voltage 220v
Voltage reference 0.7 u un .2 b -1
Current specifications 10-40a
Reference frequency 50hz
Grading accuracy ++ level
Starting current 0.4% ib
Voltage power lines 0.8w
Communication transmission distance 5m
Environmental conditions -25f¬f+70f¬
Relative humidity -_85%
Automatic relay depth
Data transmission speed
Center frequency
Dimensions
Electric meter
The main functions and features :
1. Energy measurement ways: total single-phase power meritorious =positive meritorious + reverse meritorious.
2. Right through infrared interface programming meter settings and copied sheet data to support meter reading with shrinking table, table factory default is bar code numbers.
3. After the blackout enter low-power work, in the blackout shows that the current state of total consumption, continuous 24-hour blackout revealed about the closure.
4. Meter procedural device to prevent the failure caused flight function, and after the failure to stop measurement.
Main technical parameters
Reference voltage 220v
Voltage reference 0.7 u un .2 b -1
Current specifications 10-40a
Reference frequency 50hz
Grading accuracy ++ level Starting current 0.4% ib
Voltage power lines "2w
Communication transmission distance 5 meters
Environmental conditions -25fªf+55fª Relative humidity 25f+95+¦
Automatic relay depth Data transmission speed
Center frequency Dimensions 150 * 122 * 56.5
The main functions and features :
Meter circuit design and selection of the components are according as the tolerance of greater choice of environment, so we can guarantee long-term stability of a piece of work. Basically error will not affected by the frequency, temperature, high harmonics, and the installation of location is arbitrary. After sealing unit manufactured without adjustment, greatly reduced the power sectorf+s workload of testing and calibration, meter - button box with pulse interface light coupler facilitate error testing. Detection the constant of pulse output / kw.H to find weather it is the same as constant table marked on nameplate meter, meter also provides low-frequency pulse acquisition (opts). When the one phase of three-phase three-line network is broken, three-phase four-wire network with a two-phase power outages, the watt-hour meter still normal, and display the lost pressure. Power meter in the factory before carefully debugging and test the installation of qualified lead seals. Energy applies to an ambient temperature of -25 fp c to 70 fp c and relative humidity over 85% of the region.
Main technical parameters
Reference voltage 220/380v 3 *
Voltage reference 0.7 u un .2 b -1.
Current specifications 3 * 5 (20) a.
Reference frequency 50hz.
Grading accuracy 2.0
Starting current 0.4% ib.
Voltage power lines "0.8w
Communication transmission distance 5m.
Environmental conditions -25fï+70elative humidity -_85%
Automatic relay depth Data transmission speed
Center frequency Dimensions.
Current specifications 10-40a
Reference frequency 50hz.
Grading accuracy 2.0
Starting current 0.4% ib.
Voltage power lines "2w
Communication transmission distance 5m.
Environmental conditions -10f¦f+50f¦relative humidity
Automatic relay depth
Data transmission speed
Center frequency
Dimensions 166 * 123 * 74.