LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LEDâ??s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and a-molding integrating sphere with holder base. This sphere is more round and the test result is more accruate than the traditional integrating sphere.
Measures:
â?¢ Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
â?¢ Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, WPE, EQE, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
â?¢ Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic(Optional)
â?¢ LED Light Aging Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82
High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufacturer or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detailed PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure±0.3nm, Wavelength Reproducibility: ±0.1nm
Sample Scanning Steps: ±0.1nm
Accuracy of Chromaticity Coordinate (x, y): ±0.002 (under Standard A Lamp)
Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
Stray light:
The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) < Basic testing methods of Glow wire, basic testing methods of Glow wire device>, UL 746A, IEC829, DIN695 and VDE0471.
What is glow wire test?
The Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. It uses high-temperature coating spraying on steel structure and imported instrument display, with easy operation and stable performance. The glow wire testing equipment is applicable to flame resistance test of all levels of QC departments and corresponding enterprises.
Specifications:
Heating temperature: adjustable continuously within the range of 25~1100C, the accuracy of temperature is 1C, the resolution of temperature is ±3C
Glow-wire time: 0.1-999.9s±0.1s(time range is adjustable)
Ignition time: 0.1-999.9s, auto record, manual pause
Flame-out time: 0.1-999.9s (auto record and manual pause)
Glow wire pressure on test specimen: 1±0.2N. Limiting pressure depth is 7mm
Glow wire: 4 nickel (80) and chromium (20) Made in specific dimensions.
Thermocouple: �?0.5 armored nickel & chromium/nickel-chromium wire, K Type.
Automatic departure: While reaching specified glowing time, test specimen will depart from glow wire automatically.
To save the delivery cost for the oversea market, LISUN designed a compact version glow-wire tester weighing less than 50kg. (Customer need to prepare additional ventilation system for ZRS-3HS)
According to IEC60695-2-2, IEC60695-11-5 and GB/T-5169.5, ZY-3/ZY-3S needle flame test equipment is applied in the production and quality control department of lighting products, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, the apparatus is suitable for the industry of insulation material, engineering plastics and solid combustible material.
Specifications: Angle of burner: 45 (when in test) / (when adjust the flame's height)
Needle flame burning time: 0~999.9s±0.1s (adjustable, 30s in general)
â?¢ After-flame time: 0~999.9s�±0.1s, auto record and pause manually
â?¢ Height of flame: 12mm�±1mm (gauge is included)
â?¢ Gas: 95% butane
â?¢ Test range of temperature: 0~1000â??
â?¢ The temperature rises from 100â??�±2â?? to 700â??�±3â?? within 23.5 seconds�±1s
â?¢ Thermocouple: �¦0.5mm K type
â?¢ Applied with touch screen and remote control
To save the delivery cost for the oversea market, LISUN designed a compact version needle flame test equipment weighing less than 50kg. (Customer need to prepare additional ventilation system for ZY-3S)
The SG61000-5 is an automatic surge generator (also called lightning surge immunity test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) .
How does a surge generator work?
The SG61000-5 surge generator provides a common basis for evaluating the resistance of power cords and internal connectors of different equipment to high energy transient interference caused by natural lightning surge induction and large capacity load switching. It fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires photometric, colorimetric and electrical measurement. The measured data meets the requirements of CIE 177, CIE84, CIE-13.3, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IES LM-79-19, Optical-Engineering-49-3-033602, IESNA LM-63-2, ANSI-C78.377 and GB standards
The Sphere System Configuration:
CCD Spectroradiometer (LMS-7000), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC-S Series), AC Power Source (LSP-500VAS), Integrating Sphere (IS-1.5MA-CASE and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W)
Measurement:
Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI (Ra, R1 to R15), Spectrum Test, TM30 (Rf, Rg), CQS
Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, PAR, PPF
Electrical: Voltage, Current, Power, Power Factor, Harmonic (Optional)
Specification:
Spectral Range Wavelength: 350nm~950nm(LMS-7000VIS) (200~1050nm is optional)
Spectral Wavelength Accuracy: ±0.5nm Wavelength Reproducibility: ±0.5nm
Sample Scanning Steps: �±0.1nm
Accuracy of Chromaticity Coordinate (IOx, y):±0.003 (under Standard A Lamp)
â?¢ Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5%
Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3)
Photometric linear: �±0.5%
Stray light:
LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer â?? Flicker Tester is equipped with Class A photo detector, so the sampling speed is up to 100kHz. It fully meets the requirement of BASIC, Energy Star V2.1, IEC TR 61547-1:2020 IEC-Pst, CA CEC, ASSIST, CIE TN006-2016 CIE SVM, IEEE Std 1789 standards, etc. It is professional for flicker test of LED lights and lamps, energy-saving lamps, etc. According to EU directives 1194/2012, 2009/125 / EC, SASO2902, COMMISSION DELEGATED REGULATION (EU) 2019/2015, COMMISSION REGULATION (EU) 2019/2020 and IEC60969 â??Self-ballasted Lamps for General Lighting Servicesâ??Performance Requirementsâ?? and other requirements. The LSRF-3 can connects with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft)
What is the definition of type C goniophotometer?
LSG-6000 Moving Detector Goniophotometer (Mirror Type C) was manufactured by LISUN completely meets LM-79-19, IES LM-80-08, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-121, CIE S025, SASO 2902, IS16106 and EN13032-1 clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG-5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The darkroom can be designed according to the customerâ??s existing room size.
What is the use of goniophotometer?
LSG-6000 gonio photometer manufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.