Agasthya 2013 Series Dual Pass Transmissometer
Dust Monitor BI 7000
Path Length 1 20 m flange to flange separation
Measuring Range 0 -1000 mg/m3 user selectable
Units of measurement mg/m3, mg/Nm3, % Opacity
Accuracy 1% relative to the maximum range
Resolution 1mg/m3
Drift with Temperature 1% over any 20C in the operating range
Operating Wavelength510 540 nm Green LED
Stack Temperature 300 C
Power Supply 110 230 VAC
Air Supply 5 10 m3/hr Flow & 500 mbar Pressure. Must exceed maximum stack pressure.
Air Inlet Connection 1 BSP threaded
Output 4 20 mA Analog output
Digital Interface RS 485, MODBUS protocol
Mounting Wall Electronic Unit
Enclosure Rating IP 65
Tx & Rx Junction Box Rating IP 65
Cable 2 core screened cable of 0.5mm2,8 meters between Tx & Rx
6 core screened cable of 0.5mm2,25 meters between Rx & Electronic Unit
Ambient Temperature -20 to 50 C
Operating Humidity 5 95%
Direct measurement in exhaust flue gas flow In situ
Dual Pass for accurate reading
Unit programmable in mg/m3, mg/Nm3, % Opacity
RS 485, MODBUS protocol
Rugged design with no moving parts so low maintenance
Green LED source for long lifetime stability
IP65 rating Enclosure
The best price performance on the market designed with user requirements foremost in mind
Continuous Emission Monitoring System
BI7000
Sensor Technology
Non Dispersive Infrared Absorption (NDIR), Zirconia (ZrO2),
Paramagnetic, Ultraviolet Doppler Optical Absorption Spectroscopy (UV DOAS),
Tuneable Diode Laser Spectroscopy (TDLS) Non Dispersive Ultravoilet Absorption (NDUV)
Measurement Gas
CO : 0-5000 ppm scalable
NOx : 0-1000 ppm scalable
SO2 : 0-1000 ppm scalable
CO2 : 0-20% scalable
O2 : 0-30% scalable
Cl2 : 0-30 ppm scalable
HCl : 0-200 ppm scalable
HF : 0-30 ppm scalable
H2S : 0-200 ppm scalable
HC : 0-5% scalable
NH3 : 0-500 ppm scalable
Analog Output: 4-20mA analog output
Digital Interface RS 485, MODBUS Protocol
Relay Output 2 Nos. relay for alarms
Power Supply 110/230 VAC, 50 Hz
Dimension 19 Rack
Heated Sampling Probe
Operating temperature : Max. 400 C
Mounting : Flange type. 2, 150 rating RF
Max. working pressure : 6 bar
Voltage : 110-230 V, 50 /60 Hz
Heating : Self-regulating 180C
For dust concentration : Upto 5 g/m
MOC : SS 316
Heated Sample Gas Line
Process Tube : PTFE / SS
Process Tube Size : 1/4 inch OD
Operating Voltage : 230 V AC
Max. Operating Temperature : 200 C
Sample Conditioning Unit with Industrial Cabinet
Aspirator/Pump for sampling flue gas
Pre and post cooler fine filters to remove drain, dust and mist in sample gas
Auto drain and auto purging (blow back) facilities
2 way solenoid valves for switching, sampling, purging, draining and calibration
Flowmeter to regulate and monitor the flow of sample gas
Drain pump for continuous removal of condensate
Sample Gas Cooler
Industrial Cabinet Dimension: 1500 (H) x 600 (W) x 800 (D) mm
Agasthya 2013 Series Insitu Zirconia Oxygen Analyzer
BI 2100-HL (upto 900 deg C)
Technology Zirconia
Range 0100% O2 Programmable
Accuracy 0.5% of FS
Resolution 0.01%
Repeatability 0.5% of FS
Response Time T90 3 sec
Process Gas Temperature 900
Probe MOC Inconel
Diffusion Element Unbreakable Ceramic. Sintered Steel filter as optional
O2 Probe Length 250, 500, 750, 1000, 1500, 2000 mm
Flange ANSI Cl. 150 3RF. Other Flanges on request
Reference Air Clean & Dry Instrument quality air (2 LPM)
Area Classification Safe Area. (Explosion Proof on request.)
Display Keypad LCD Display
Power 24 VDC. 230 V AC optional on request
Output 4-20 mA Analog Output & 3 Nos. Relay Output
Digital Interface RS 485, Modbus protocol
Ambient Temperature
Mounting Wall. Rack optional on request.
Enclosure Rating IP65
Calibration Auto & Manual
Cable between Sensor & Electronic 4 core, 25 meter
Agasthya 2017 Series Portable Flue Gas Analyzer
BI 100 (O2)
Sensor Technology Electrochemical (EC)
Measurement Gas
O2 0-30% scalable
Response Time (T-90) 30 seconds
Display Keypad LCD Display
Power 80-230 VAC, 50 Hz, Adaptor
Battery Lithium-ion rechargeable batteries
Communication USB
Data Storage Up to 150 set of data
Enclosure Handheld
Operating Temperature 4 to 50C
Dimension 215 (L) x 120 (B) x 40 (H) mm
Area Classification General Purpose
Sampling Probe available as per temp max upto 1400 degC
Probe length : Customised
32-Bit Cortex-M3 ARM Processor
Automatic zeroing when the analyzer is switched ON
Robust/Rugged design that is easy to operate and maintain
Fast warm-up and response
Rechargeable battery operation
Built in sample pump, filter and flowmeter
Condensate removal
Stainless steel probe with sample hose
Battery lifetime up to 8 hours
150 set of data storage
USB for Charging & Data communication
Powerful windows software for Analyzer data communication