% 80 less gas than the competition
With Axiss match load to cartridge method, you never have to worry about tanks of EtO. Axis Products offers cutting-edge technologies and expertise in sterilization with the only system that offers multi-load capability.
The new diffusion chamber provides extra protection to the operator in case of accidental activation. Its robust design and polyurethane body make the EO Gas cartridge one of the most reliable tools for releasing the ethylene oxide gas.
Operator safety is ensured by the double protection of the trigger via a plastic lock and a safety seal.
The Axis Ethylene Oxide Scrubbers has been designed to work with all models of Axis AX series sterilizers. It uses online installation technology of the exhaust line of the sterilizer and provides simple connections usage without tools. The scrubber body and hoses; made of stainless steel and consist of 50 kg ion exchange activated carbon extracting over 98% of the ethylene oxide in the exhaust air stream.
Through Axis AX series sterilizers which are built-in with extractor fan, external extractor fan and power requirement has been eliminated.
High Efficiency
Easy Installation and Replacement
Eliminates risk of leakage thanks to itâ??s simple design and connections
Extra space, pipe and extractor fan free
This product is projected in order to be used at surgery rooms. By the help of this Rollboard, the patient can be transferred to his bed easily after surgery. There is a special cloth on the surface so the patient will be transferred safely without moving. This surface cloth turns on the inside material and allows the patient to transfer. Also, this transfer can be made by one or two persons.
Teasy to clean allows
X-RAY lights compatible
Flexible in order to carry easily
AXIS Incubators are specially designed for use with Verify Self Contained Biological Indicators (SCBls). The incubators are available in single or dual temperatures for steam and Ethylene Oxide (EO) sterilization process. For steam, the incubators aperture at 60�°C, For Ethylene Oxide, they operate 37�°C. Available for either 120 or 220 V electric supply.
34 positions for conventional and colorimetric SCBIâ??s.
4 positions for self-contained ampoules, culture media, and protein detection pen.
A special hole for the external thermometer.
An ampoule crusher for BIs.
High technology
Useable capacity is up to 15000 liter
100% EO
Negative pressure working system
Sterilization and Aeration in the same cabinet
100% safe
Microcomputer controlled
Practical, easy use
Modular, able to add sterilization bags
Low gas consumption
Cabinet safety pressure measurement and instantaneous monitoring
Robust construction, working without risk of failure
Inox inner and an outer surface
Easy installation, no drain, water or pressure air are necessary
Axis Industrial Type of Ethylene Oxide Sterilizer is the fastest way to sterilize equipment that is heat-sensitive or susceptible to moisture. Sterilization can be performed for equipment in their original packaging and does not need extra packaging. Sterilizers using EtO cylinders which are available on the market and allows loading goods by pallets. A pair of the automatic sliding door provides easy loading, unloading, let to clean the chamber by forced air circulation after the post-operation and pass-through option for cleanroom operations. To eliminate pressure risk, security lock jaws have been installed on the sterilizerâ??s door. The inflatable silicone gasket eliminates risks of gas leakage which occurs by air pressure. System testing for gas leakage under vacuum conditions per each cycle provides full security. Devices are long-lasting thanks to their stainless steel structure. Axis Industrial Type of Ethylene Oxide Sterilizers can work under negative and positive pressures. Temperature, Time, Pressure, Humidity data recording, saving, and printing online. The system comes with a large set of spare parts as free.
Axis sterile containers are designed to protect the sterile
state of medical devices, surgical devices, surgical instruments
and electro-surgical instruments used for surgical operations,
sterilized within the sterilizer, during transport and storage; wire baskets,
silicone lawns, textile products, filters, labels, plastic seals, chemical indicator,
biological indicator, dosimeter and moisture chip holders, automatic cartridge
activator, electro-mechanical valve, observation window, such as are supported
with a large number of accessories.
Reading can be viewed instantaneously on display.
Microprocessor controlled.
Measure the ethylene oxide concentration in air in the 0-99 ppm range.
Visual and Audible Alarm (> 85 dB(A))
External Alarm output
Adjustable alarm threshold.
Fixed system installation continuously monitoring a given area.
High reliability
Instrument checks sequence.
Two-year limited warranty includes a sensor
Up to five years of sensor life.
Economic.
Axis medical packaging provides safe and reliable sterile barrier systems for medical devices, pharmaceutical solutions, and other healthcare products.
All imprints are located outside the packaging area to prevent ink pigment migration to the product.
Extra reinforced layered film to avoid tear during the opening.
Transparent, multilayer co-polymer colored film allows easy identification.
Superior barrier with 60 gsm or 70 gsm medical kraft paper.
Can be easily sealed with all sealing machines.
Non-toxic accurate, process indicators for steam and EO gas conforming to the ISO 11140.
Formaldehyde (FO) and Hydrogen peroxide (Plasma) Indicator available upon request.
Strong seal-strength, visible sealing lines.
Clean fiber-free opening.
Triple band strong seal creates three independent barriers to contamination.
While reducing the risk of fiber tear.
All materials comply with international standards.
Opening direction marked.
Conformity with EN 868-5.
AXIS self-contained Steam biological indicators designed for monitoring the efficacy of 121 C, 132 C,134 C and 135 C steam sterilization cycles. It is easy to use; no sophisticated laboratory testing or analysis is required. The biological indicator contains Geobacillus stearothermophilus ATCC 7953 bacterial spores on a filter paper carrier packaged within a plastic tube and a cap. Inside the tube, there is a sealed-glass ampoule of specially-formulated culture medium containing a color indicator that changes color when spores grow.
Chemical Indicator on the label provides an instant indication of exposure.
24hr-3hr-1hr-30min and 20min options.
The expiration date of 2 years from the date of manufacturing
Use in conjunction with Axis AXRD-100 Rapid and AXDL-100 Dual Incubator