Rosemoun 3051S Coplanar Pressure Transmitter
Introduction
The Rosemount 3051S Coplanar Pressure Transmitter is designed with the patented Coplanar technology and is the no-equal solution for pressure, flow and level measurements. This scalable platform seamlessly integrates with manifolds, primary elements and seal solutions and optimizes performance for accurate differential, gage and absolute pressure measurements. With the SuperModule platform, this transmitter resists overpressure and line pressure effects to maintain unmatched performance.
Specifications
Warranty
Up to 15-year limited warranty
Rangedown
Up to 200:1
Communication Protocol
4-20 mA HART,WirelessHART, FOUNDATION fieldbus
Measurement Range
Up to 2000psi (137,89 bar) Differential, Up to 2000psig (137,89 bar) Gage, Up to 4000psia (275,79 bar) Absolute
Process Wetted Material
316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST
Diagnostics
Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics
Certifications/Approvals
SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE, hazardous location, see full specs for complete list of certifications
Features
Patented Rosemount Coplanar technology offers optimized performance as a pressure, DP Flow and DP Level solution
Best-in-class, scalable architecture enhances performance, functionality and process connections
Transmitter arrives fully assembled and leak tested for simple installation and maintenance
All-welded hermetic SST SuperModule platform resists overpressure and line pressure effects to ensure 0.025% accuracy
Ultra and Ultra for Flow performance classes deliver 15-year stability and 15-year limited warranty
200:1 rangedown produce reliable measurements and wide application flexibility
Integrates seamlessly with 4-20 mA HARTÂ WirelessHART, FOUNDATIONâ?¢ fieldbus protocols for application flexibility
SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Advanced diagnostics provide diagnostic coverage to detect electrical loop issues and abnormal process conditions
Remote display and interface offers easy access to process and device information
Micro motion cng050 coriolis flow meter
Introduction
Single-meter cng flow meters meet the challenges of measuring compressed natural gas for custody transfer in light- and heavy-duty vehicle dispensers while reducing fill time with higher flow rate capability.
Specifications
Gas accuracy / repeatability
±0.50% of batch (0.25% of rate)
Line size
1/2 3/4(dn15 dn20)
Pressure range
5000 psig (345 barg)
Temperature range
-40 to 257 f ( - 40 to 125 c)
Electronics (soft)
Expansive i/o options including ma, frequency, discrete input/output , hart, modbus, ethernet/ip, foundation fieldbus
Turndown
10:01
Features
Satisfy needs for light- and heavy-duty vehicle dispensers with a purpose-built, single-meter solution
Use with most fluids with available 316l stainless steel construction
Choose from a wide range of transmitter options, including direct-connect, to accommodate dispenser design requirements
Broad range of meter approvals and certifications, including; csa (class 1 div 1 groups c and d, class 1 div 2 groups a, b, c and d, class ii div 1 groups e, f and g), atex, nepsi, iecex, ingress protection 66/67, and namur
Save time with a compact design with no moving parts, requiring no special mounting or flow conditioning
Rely on custody-transfer-approved certification
Common models
Cng050s239nqbmazzz
Cng050s239nabmazzz
Cng050s239ncbmazzz
Cng050s239nwbmazzz
Cng050s239ndbmazzz
Cng050s290nqbmazzz
Cng050s290nabmazzz
Cng050s290ncbmazzz
Cng050s290nwbmazzz
Cng050s290ndbmazzz
Cng050s291nqbmazzz
Cng050s291nabmazzz
Cng050s291ncbmazzz
Cng050s291nwbmazzz
Cng050s291ndbmazzz
Micro motion 1500 and 2500 compact control room transmitter
Introduction
Powered by mvd technology, 1500/2500 din rail-mounted transmitters easily fit into control room panels, requiring only 0.03 of space. A simple four-wire connection to the sensors for power and signal eliminates the expense of custom cabling.
Specifications
Available outputs
Model 1500 : for applications requiring one flow rate variable ( in milliamp and a frequency/pulse output
Model 2500 : for applications requiring simultaneous monitoring of multiple flow variables in combinations of outputs (milliamp, frequency, and discrete i/o)
Housing
Polyamide pa 6.6
Weight
0.52 lbs (0.24 kg)
Dimensions
L ã? w ã? h 4.41 in (112mm) x 1.78 in (45mm) x 3.9 in (99mm)
Hazardous area specifications
Csa class i, div. 2, groups a, b, c, and datex ce 0575 atex ii (2) g [eex ib] iib/iic
For atex compliance, ambient temperature is limited to -40 to +131f (-40 to +55c)
Power requirements
19.2 to 28.8 vdc, 6.3 watts maximum
Marine approvals
Det norske veritas - models 1500 and 2500 only
American bureau of shipping (all models)
Features
Cut wiring expenses with a remote-mount transmitter using 35 mm din rail
Easily fit in control rooms just a 0.03ft space requirement versus 1.0ft typically required for coriolis transmitters
Simplify configuration with a four-wire connection to the sensors for power and signal
Diagnose for performance under entrained gas and batching from empty applications with mvd digital processing
Verify sensor health in-line, with the process running and without secondary references with true in-situ verification
Rosemount 2088 Gage and Absolute Pressure Transmitter
Specifications
Warranty
Up to 5-year limited warranty
Rangedown
Up to 50:1
Communication Protocol
4-20 mA HART, 1-5 V Low Power HART
Measurement Range
Up to 4,000 psig (275,8 bar) Gage, Up to 4,000 psia (275,8 bar) Absolute
Process Wetted Material
316L SST, Alloy C-276
Diagnostics
Basic Diagnostics
Certifications/Approvals
NSF, NACE, hazardous location, see full specs for complete list of certifications
Features
Local Operator Interface (LOI) features straightforward menus and built-in configuration buttons for ease-of-use
Factory-assembled and leak-checked integral manifold and remote seal solutions deliver a quick start-up
Available protocols include 4-20 mA HART and 1-5 Vdc HART Low Power for application flexibility
Lightweight, compact design allows for easy installation
Normal Models
2088G1S22A1B4E5M5
2088G2S22A1B4E5M5
2088G3S22A1B4E5M5
2088G4S22A1B4E5M5
2088G1S22A1B4E5M5
2088G1S22A1B4E5M5
2088G1S22A1B4E5M5
2088G1S22A1B4E5M5
2088G1S22A1B4E5M5
2088G1S22A1B4E5M5
2088A1S22A1B4E5M5
2088A2S22A1B4E5M5
2088A3S22A1B4E5M5
2088A4S22A1B4E5M5
2088AS22A1B4E5M5
2088AS22A1B4E5M5
2088AS22A1B4E5M5
2088AS22A1B4E5M5
2088AS22A1B4E5M5
2088AS22A1B4E5M5
2088G1S33A1B4E5M5
2088G2S33A1B4E5M5
2088G3S33A1B4E5M5
2088G4S33A1B4E5M5
2088G1S33A1B4E5M5
2088G1S33A1B4E5M5
2088G1S33A1B4E5M5
2088G1S33A1B4E5M5
2088G1S33A1B4E5M5
2088G1S33A1B4E5M5
2088A1S33A1B4E5M5
2088A2S33A1B4E5M5
2088A3S33A1B4E5M5
2088A4S33A1B4E5M5
2088A1S33A1B4E5M5
2088A1S33A1B4E5M5
2088A1S33A1B4E5M5
2088A1S33A1B4E5M5
2088A1S33A1B4E5M5
2088A1S33A1B4E5M5
2088G1S2BA1B4E5M5
2088G2S2BA1B4E5M5
2088G3S2BA1B4E5M5
2088G4S2BA1B4E5M5
2088G1S2BA1B4E5M5
2088G1S2BA1B4E5M5
2088G1S2BA1B4E5M5
2088G1S2BA1B4E5M5
Rosemount 2051 Coplanar Pressure Transmitter
Specifications
Warranty
Up to 5-year limited warranty
Rangedown
Up To 100:1
Communication Protocol
4-20 mA HARWirelessHART FOUNDATION� Fieldbus, PROFIBUS 1-5 V Low Power HART®
Measurement Range
Up to 2000 psi (137,9 bar) Differential, Up to 2000 psig (137,9 bar) Gage
Process Wetted Material
316L SST, Alloy C-276, Tantalum
Diagnostics
Basic Diagnostics
Certifications/Approvals
SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE hazardous location, see full specs for complete list of certifications
Features
Performance up to 0.05% of span accuracy
Patented coplanar technology allows direct mounting to pressure, flow or level solutions for installation flexibility
Delivered fully assembled to manifolds, diaphragm seals or primary flow elements for straightforward installation
Local Operator Interface offers easy-to-use menus and built-in configuration buttons for streamline commissioning
SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Normal Models
2051CD0A02A1AB1H2L4M5
2051CD0A02A1AB1H2L4M5K5
2051CD1A02A1AB1H2L4M5K5
2051CD2A02A1AB1H2L4M5K5
2051CD3A02A1AB1H2L4M5K5
2051CD4A02A1AB1H2L4M5K5
2051CG5A02A1AB1H2L4M5K5
2051CG1A02A1AB1H2L4M5E5
2051CG2A02A1AB1H2L4M5E5
2051CG3A02A1AB1H2L4M5E5
2051CG4A02A1AB1H2L4M5E5
2051CG5A02A1AB1H2L4M5E5
2051CG1A02A1AB1H2L4M5I5
2051GP1A2B21AB4M5
2051GP2A2B21AB4M5
2051GP3A2B21AB4M5
2051GP4A2B21AB4M5
2051GP5A2B21AB4M5
2051GP1A2B21AB4M5K5
2051GP2A2B21AB4M5K5
2051GP3A2B21AB4M5K5
2051GP4A2B21AB4M5K5
2051GP5A2B21AB4M5K5
2051GP1A2B21AB4M5E5
2051GP2A2B21AB4M5E5
2051GP3A2B21AB4M5E5
2051GP4A2B21AB4M5E5
2051GP5A2B21AB4M5E5
2051GP1A2B21AB4M5I5
2051GP2A2B21AB4M5I5
2051GP3A2B21AB4M5I5
2051GP4A2B21AB4M5I5
Micro motion 1700 and 2700 field and integral-mount transmitter
Introduction
Powered by mvd technology, these versatile field-mount transmitters are built with an advanced architecture and provide a wide variety of i / o and application flexibilities, making them the top choice for compact integral mounting.
Specifications
Housing
Polyurethane-painted cast aluminum or cf3m stainless steel; nema 4x (ip66)
Weight
Painted aluminum, 4-wire remote:
With display: 8 lb (4 kg)
Without display: 7 lb (3kg)
Power
18 to 100 vdc or 85 to 265 vac
Mounting
Integral or remote mounting options (stainless steel versions are always remote mounted)
May be remotely connected to any 4-wire or 9-wire micro motion sensor
View product data sheet for full details.
Available outputs
1700: ma w/ bell 202 hart fo/do rs485 hart and modbus
2700:
Analog: ma w/ bell 202 hart fo/do rs485 hart and modbus
View product data sheet for full details.
Features
Maximize flexibility with integral or remote mounting
Receive diagnostics for performance under entrained gas and batching from empty applications with mvd digital processing
Lower wiring costs and install easily and quickly
Eliminate the need for additional instruments with concentration and net-flow measurement
Rely on custody-transfer approval and certification for sil2 and sil3
Verify sensor health in-line, with the process running and without secondary references with true in-situ verification
Gain access to additional diagnostics and process information without added wiring costs with wirelesshart
Simplify flow-meter access with rugged class i, division 1 / zone 1 housing with an optional local operator interface
Micro Motion 3500 and 3700 Controller and Transmitter
Introduction
With combined Coriolis transmitter functions and PLC capabilities, the Micro Motion Series 3000 is built for industy-focused solutions, including net oil computer, enhanced density, custody transfer and marine fuel bunkering solutions.
Specifications
Housing
3500 Rack:
19-inch (486.2 mm) rack-mount housing meets DIN standard 41494 and IEC 297-3
3500 Panel:
Front panel with bezel is rated NEMA 4X (IP65) Front panel is aluminum with laminate overlay
Housing
3700: Housing is epoxy painted aluminum, bracket is 304 SS
NEMA 4X (CSA) and IP66/IP67 (ATEX/IECEx)
Weight
3500: Maximum 3.5 lb (1.6 kg), excluding prepared cables
3700: 19 lb (8.6 k)
3500/3700 Interface
Display:
Backlit LCD, 128 x 128 pixel, bit map Adjustable contrast Non-glare, chemical-resistant acrylic lens
3500/3700 Interface
Interface:
(keypad membrane switch)
Large push buttons with tactile feedback
Software-defined function keys
Chemical-resistant polyester
Features
Decrease your plant's labor, maintenance and operating costs with transmitter functions and PLC capabilities
Increase efficiency, accelerate throughput and improve product quality
Eliminate the need for external tools with full configuration capabilities
Improve interaction with a large, programmable display and descriptive alarms for easy setup, control and operation
Maximize uptime and process consistency with MVD technology that speeds response and enables multivariable measurement
Rosemount 3051 Coplanar Pressure Transmitter
Specifications
Warranty
Up to 5-year limited warranty
Rangedown
Up to 150:1
Communication Protocol
4-20 mA HART,WirelessHART, FOUNDATION fieldbus, Profibus, 1-5 V Low Power HART
Measurement Range
Up to 2000psi (137,89 bar) Differential, Up to 2000psig (137,89 bar) Gage, Up to 4000psia (275,79 bar) Absolute
Process Wetted Material
316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST
Diagnostics
Basic Diagnostics, Power Advisory Diagnostics
Certifications/Approvals
SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE, hazardous location, see full specs for complete list of certifications
Common models
3051CD2A02A1AB1H2L4M5
3051CD3A02A1AB1H2L4M5
3051CD4A02A1AB1H2L4M5
3051CD5A02A1AB1H2L4M5
3051CD1A02A1AB3H2L4M5
3051CD2A02A1AB3H2L4M5
3051CD3A02A1AB3H2L4M5
3051CD4A02A1AB3H2L4M5
3051CD5A02A1AB3H2L4M5
3051CD1A02A1AB1H2L4M5K5
3051CD2A02A1AB1H2L4M5K5
3051CD3A02A1AB1H2L4M5K5
3051CD4A02A1AB1H2L4M5K5
3051CD5A02A1AB1H2L4M5K5
3051CD1A02A1AB1H2L4M5E5
3051CD2A02A1AB1H2L4M5E5
3051CD1A02A1AB1H2L4M5I5
3051CD2A02A1AB1H2L4M5I5
3051CD3A02A1AB1H2L4M5I5
3051CD4A02A1AB1H2L4M5I5
3051CD5A02A1AB1H2L4M5I5
3051CD1A02A1AB3H2L4M5K5
3051CD2A02A1AB3H2L4M5K5
3051CD3A02A1AB3H2L4M5K5
3051CD4A02A1AB3H2L4M5K5
3051CD5A02A1AB3H2L4M5K5
3051CD1A02A1AB3H2L4M5E5
3051CD2A02A1AB3H2L4M5E5
3051CD3A02A1AB3H2L4M5E5
3051CD4A02A1AB3H2L4M5E5
3051CD5A02A1AB3H2L4M5E5
3051CD1A02A1AB3H2L4M5I5
3051CD2A02A1AB3H2L4M5I5
3051CD3A02A1AB3H2L4M5I5
3051CD4A02A1AB3H2L4M5I5
3051CD5A02A1AB3H2L4M5I5
3051CD1A22A1AB4M5
3051CD2A22A1AB4M5
3051CD3A22A1AB4M5
3051CD4A22A1AB4M5
3051CD5A22A1AB4M5
3051CD1A22A1AB4M5DF
3051CD2A22A1AB4M5DF
3051CD3A22A1AB4M5DF
3051CD4A22A1AB4M5DF
3051CD5A22A1AB4M5DF
3051CD1A22A1AB4M5K5
3051CD2A22A1AB4M5K5
3051CD3A22A1AB4M5K5
3051CD4A22A1AB4M5K5
3051CD5A22A1AB4M5K5
3051CD1A22A1AB4M5E5
3051CD2A22A1AB4M5E5
3051CD3A22A1AB4M5E5
3051CD4A22A1AB4M5E5
3051CD5A22A1AB4M5E5
3051CD1A22A1AB4M5I5
3051CD2A22A1AB4M5I5
3051CD3A22A1AB4M5I5
3051CD4A22A1AB4M5I5
3051CD5A22A1AB4M5I5
Rosemount 2090P Pulp and Paper Pressure Transmitter
Introduction
With its compact size and rugged construction, the Rosemount 2090P Pulp and Paper Pressure Transmitter is ideal for the pulp and paper industries. This lightweight transmitter is engineered with a 1 in. flush mount compatible with PMC process connection or 1 1/2 in. threaded mounting connection. This transmitter can be calibrated to ranges as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 300 psi (20.7 bar) for reliable measurement capabilities.
Specifications
Accuracy
0.20%
Power Supply
10.5-42.4 V
Warranty
Up to 5-year limited warranty
Rangedown
Up to 20:1
Communication Protocol
4-20 mA HART
Measurement Range
Up to 300 psig (20,7 bar) Gage, Up to 300 psia (20,7 bar) Absolute
Process Wetted Material
316L SST
Diagnostics
Basic Diagnostics
Certifications/Approvals
Hazardous location, see full specs for complete list of certifications
Features
1 in. flush mount compatible with PMC process connection or 1 1/2 in. threaded mounting connection available
Calibrates as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 300 psi (20.7 bar) for application flexibility
Lightweight, compact design for easy installation
Fully configurable LCD displays process variable, percent of range and diagnostic message
Communicates via 4-20 mA HART� protocol for streamlined host integration
Normal Models
2090PA1S22A1B4M5
2090PA2S22A1B4M5
2090PA3S22A1B4M5
2090PG1S22A1B4M5
2090PG2S22A1B4M5
2090PG3S22A1B4M5
2090PA1S22C1B4M5
2090PA2S22C1B4M5
2090PA3S22C1B4M2090PG1S22C1B4M5
2090PG2S22C1B4M5
2090PG3S22C1B4M5
2090PA1S22C2B4M5
2090PA2S22C2B4M5
2090PA3S22C2B4M5
2090PG1S22C2B4M5
2090PG2S22C2B4M5
2090PG3S22C2B4M5
2090PA1S22D1B4M5
2090PA2S22D1B4M5
2090PA3S22D1B4M5
2090PG1S22D1B4M5
2090PG2S22D1B4M5
2090PG3S22D1B4M5
2090PA1S22D2B4M5
2090PA2S22D2B4M5
2090PA3S22D2B4M5
2090PG1S22D2B4M5
2090PG2S22D2B4M5
2090PG3S22D2B4M5
2090PA1S22G1B4M5
2090PA2S22G1B4M5
2090PA3S22G1B4M5
2090PG1S22G1B4M5
2090PG2S22G1B4M5
2090PG3S22G1B4M5
2090PA1S22G2B4M5
2090PA2S22G2B4M5
2090PA3S22G2B4M5
2090PG1S22G2B4M5
2090PG2S22G2B4M5
2090PG3S22G2B4M5
Rosemount 2090f hygienic pressure transmitter
Introduction
Designed for hygienic applications, the rosemount 2090f hygienic pressure transmitter is specifically engineered for the pharmaceutical and food and beverage industries. Built with industry standard process connections, this device connects to sanitary fittings without special mounting hardware. In addition, this hygienic pressure transmitter conforms to 3-a sanitary standards, allowing you to meet tough process requirements.
Specifications
Accuracy
0.20%
Power supply
10.5-42.4 v
Warranty
Up to 5-year limited warranty
Rangedown
Up to 20:1
Communication protocol
4-20 ma hart
Measurement range
Up to 300 psig (20, 7 bar) gage, up to 300 psia (20, 7 bar) absolute
Process wetted material
316l sst
Diagnostics
Basic diagnostics
Certifications/approvals
3-a sanitary standards, hazardous location, see full specs for complete list of certifications
Features
Tri clamp process connection designed for standard sanitary fittings
Conforms to 3-a sanitary standards for hygienic application compliance
Utilizes single-filled sensor system for reliability and accuracy
Features cip/sip service for process temperatures of up to 140 â??
Fully configurable lcd displays process variable, percent of range and diagnostic messages
Normal models
2090fa1s2de1b4m5
2090fa2s2de1b4m5
2090fa3s2de1b4m5
2090fg1s2de1b4m5
2090fg2s2de1b4m5
2090fg3s2de1b4m5
2090fa1s2df1b4m5
2090fa2s2df1b4m5
2090fa3s2df1b4m5
2090fg1s2df1b4m5
2090fg2s2df1b4m5
2090fg3s2df1b4m5
2090fa1s2de2b4m5
2090fa2s2de2b4m5
2090fa3s2de2b4m5
2090fg1s2de2b4m5
2090fg2s2de2b4m5
2090fg3s2de2b4m5
2090fa1s2df2b4m5
2090fa2s2df2b4m5
2090fa3s2df2b4m5
2090fg1s2df2b4m5
2090fg2s2df2b4m5
2090fg3s2df2b4m5