Cummins Diesel Generator Set 24GF
Diesel Generator Set Data
Set Type: XG-24GF
Standby Power: 24KW/30KVA
Prime Power: 22KW/27KVA
Rated Current: 39(A)
Rated Frequency: 50(Hz)
Start-up time: 5ï½?6(s)
Power Factor: 0.8(Lag)
Rated Voltage: 400/230(V)
Standard Features
1. Engine: DCEC Cummins 4B3.9-G2
2. Radiator 50â?? max
3. Fans are driven by belt, with safety guard
4. 24V charge alternator
5.Dry type air filter, fuel filter, oil filter
6. Alternator: single bearing alternator
7. IP23, insulation class H/H
8. Main line circuit breaker
9. Standard control panel
10. Absorber
11. Muffle
12. User manual
LICARDO Diesel Generator Set 24GF
Diesel Generator Set Dat
Standby Power:24KW/30KVA
Prime Power:22KW/27KVA
Rated Current:39(A)
Rated Frequency:50Hz
Start-up time:5ï6s
Power Factor:0.8Lag
Rated Voltage:400/230V
Standard Features
Engine:LICARDO K4100D
Radiator 50?? max
Fans are driven by belt, with safety guard
24V charge alternator
Dry type air filter, fuel filter, oil filter
Alternator: single bearing alternator
IP22, insulation class H/H
Main line circuit breaker
Standard control panel
Absorber
Muffler
User manual
Diesel Engine Data
Manufacturer:LICARDO Engine Co
Model:K4100D
Prime /Standby Power:0KW/33KW
Rated Speed:1500r/min
Cycle:4 stroke
Cylinder Arrangement:4 in line
Displacement:3.61L
Bore and Stroke:100*115mm
Compression Ratio:19:1
Governor Type:Mechanical
Start battery voltage:24V DC
Air Intake System
Air Intake System:Naturally aspirated
Max Intake Restriction:6.1kPa
Burning Capacity:6.2m3/min
Air Flow:168m3/min
Exhaust System
Exhaust Gas Flow:12.2m3/min
Exhaust Temperature:?¤470??
Max Back Pressure:3kpa
Fuel System
Fuel System:Direct Injection
100%( Prime Power) Load:258.4g/kwh
Oil System
Total Oil Capacity:12.5L
Oil Consumption:?¤2.04g/kwh
Oil Pressure at Rated RPM:0.30-0.50MPa
Cooling System
Cooling Way:Water-cooled
Total Coolant Capacity:28L
Max Water Temperature:95??
Alternator Data
Manufacturer:STARLIGHT/STAMFORD /SIEMENS / MARATHON /ENGGA/KEPU
Excitation Mode:Brushless self-excitation
Number of phase and Access Act:3-phase 4-wire
Connecting Type:??Y?� type connecting
Alternator Capacity:30KVA
Alternator Efficiencies:95
Overload:PRP110% load can run 1h
Protection Level:IP22-IP23
Insulation Class, Temperature Rise:H/H
Telephone Influence Factor (TIF):50
THF:2%
Voltage Regulation, Steady State:?¤±1%
Altitude:?¤1000m
Daewoo Diesel Generator Set 64GF
Diesel Generator Set Dat
Set Type: XG-64GF
Standby Output: 64KW/80KVA
Prime Output: 58KW/73KVA
Rated Current: 105(A)
Rated Frequency: 50(Hz)
Start-up time: 5ï½?6(s)
Power Factor: 0.8(Lag)
Rated Voltage: 400/230(V)
Standard Features
1. Engine:DOOSAN DI146
2. Radiator 50â?? max
3. Fans are driven by belt, with safety guard
4. 24V charge alternator
5. Dry type air filter, fuel filter, oil filter
6. Alternator: single bearing alternator
7. IP23, insulation class H/H
8. Main line circuit breaker
9. Standard control panel
10. Absorber
11. Ripple flex exhaust pipe, exhaust siphon, flange, muffler
12. User manual
YUCHAI Diesel Generator Set 40GF
Diesel Generator Set Dat
Set Type: XG-40GF
Standby Output: 40KW/50KVA
Prime Output: 36KW/45KVA
Rated Current: 65ï¼?Aï¼?
Rated Frequency: 50ï¼?Hzï¼?
Start-up time: 5ï½?6ï¼?sï¼?
Power Factor: 0.8ï¼?Lagï¼?
Rated Voltage: 400/230ï¼?Vï¼?
Standard Features
1.Engine: YUCHAI YC4D60-D21
2.Radiator 50?? max
3.Fans are driven by belt, with safety guard
4.24V charge alternator
5.Dry type air filter, fuel filter, oil filter
6.Alternator: single bearing alternator
7.IP23, insulation class H/H
8.Main line circuit breaker
9.Standard control panel
10.Absorber
11.Muffler
12.User manual
GSeries high voltage generator
VOLTAGE GENERATOR
Rated Voltage: 3kV / 3.3kV / 4.16kV / 6kV / 6.3kV / 6.6kV / 7.2kV /10kV / 10.5kV/ 11kV / 12.47kV/ 13.2kV / 13.8kV
Power Range: 400kW-10000kW
Rated Frequency: 50Hz/60Hz
Rated Speed: 1500rpm/1800rpm
Power Factor: 0.8(Lagging)
Ingress Protection: IP23 / IP44 / IP54
Insulation Class: F / H(optional)
Configuration: Single/double bearing
Excitation System: Brushless permanent magnetic generator exctitation system ( PMG )
1)Electrical Performance
Technical Characteristics
Stator of High Voltage Generator
Class F stator is wrapped with class F epoxy mica tape and mould pressed. Class H stator coil is operated with the mature class H insulation technology and impregnated in VPI (vacuum pressure impregnating) system. Both class F and class H stator coil are processed with anti-corona treatment. Meantime, the stator coil is designed with skewed slot structure to effectively reduce harmonic wave. Enhance the mechanical strength on the end of stator winding to effectively prevent and withstand the deformation on the end of stator caused by the sudden load or short circuit.
Rotor of High Voltage Generator
Triple insulated structure of the rotor coil can effectively improve the rotor turn to turn and interlayer insulation, the damp-proof and anti-corrosion ability. It will enhance the mechanical strength on the end of the winding to prevent the rotor winding from deforming under high rotation speed. Accordingly, the lifespan, reliability and environment adaptability of generator is also substantially improved. The rotating rectifier is designed as bi-section structure which is convenient for maintenance and do not require any knock down on the generator.
Winding
5/6 or 2/3 pitch option can decrease the content of voltage harmonic wave and is suitable for nonlinear load application. The standard configuration is temperature sensor, PT100 and space heater
Power Range
The power range of ENGGA high voltage generator is from 400kW to 10000kw.
Voltage Range
Standard voltage is from 3kV to 13.8kV. Special voltage is available according to customersâ?? requirement.
Frequency Range
50Hz or 60Hz are available.
Poles and Speed
The standard rotor configuration of high voltage generator is 4 pole salient rotor, with the speed at 1500r/min or 1800r/min. And 6/8/10/12/14 poles low/medium speed high voltage synchronous generator option is available.
Waveform Distortion and Telephone Interference
THD
M SERIES MARINE GENERATOR
MARINE GENERATOR
Rated Voltage: 220V / 380V / 400V / 415V / 440V /
460V / 480V / 600V / 690V / 1140V
Power Range: 40kW-3000kW
Rated Frequency: 50Hz/60Hz
Product detailï¼?
Rated Speed: 1500rpm/1800rpm
Power Factor: 0.8(Lagging)
Ingress Protection: IP23 / IP44 / IP54 / IP55
Insulation Class: H
Configuration: Single/double bearing
Excitation System: Brushless self-excitation (PMG is optional)
For more details, please contact us.
Generator ControllersDSE7320
AUTO MAINS (UTILITY) FAILURE CONTROL MODULES
The DSE7320 is a feature packed Auto Mains (Utility) Failure Control Module designed to control single diesel or gas gen-set applications.
OVERALL SIZE
240 mm x 181 mm x 42 mm (9.4â?� x 6.8â?� x 1.6â?�)
PANEL CUTOUT SIZE
220 mm x 160 mm (8.7" x 6.3")
MAXIMUM PANEL THICKNESS
8.0 mm (0.3â?�)
WEIGHT
0.86kg
PRODUCT VARIANTS
7320-01 - 7320 Auto Mains (Utility) Failure Control Module
7320-02 - 7320 Auto Mains (Utility) Failure Control Module (Htr)
SPECIFICATION
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.
LEDs and backlight will not be maintained during cranking.
MAXIMUM OPERATING CURRENT
340 mA at 12 V, 160 mA at 24 V
MAXIMUM STANDBY CURRENT
160 mA at 12 V, 80 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
MAINS (UTILITY)
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
OUTPUTS
OUTPUT A (FUEL)
15 A DC at supply voltage
OUTPUT B (START)
15 A DC at supply voltage
OUTPUTS C & D
8 A 250 V (Volt free)
AUXILIARY OUTPUTS E,F,G,H
2 A DC at supply voltage
GENERATOR
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
MAGNETIC PICK-UP
VOLTAGE RANGE
+/- 0.5 V to 70 V
FREQUENCY RANGE
10,000 Hz (max)
KEY FEATURES
Heated display option.
3-phase generator and mains (utility) sensing.
Power monitoring (kW h, kV Ar, kV Ah, kV Ar h).
Remote communications (RS232 & RS485)
Configurable inputs/outputs (9/8).
CAN and magnetic pick-up sensing.
Fuel usage monitor and low level alarms.
Tier 4 CAN engine support.
Manual/automatic load transfer.
Configurable display languages.
Power save mode.
Integral PLC editor.
Flexible sender inputs.
DSE Configuration Suite PC Software.
Configurable event log (250).
Load switching, load shedding & dummy load outputs.
volvo Diesel Generator Set 68GF
Diesel Generator Set Dat
Set Type: XG-68GF
Standby Power: 68KW/85KVA
Prime Power: 62KW/77KVA
Rated Current: 111(A)
Rated Frequency: 50(Hz)
Start-up time: 5ï½?6(s)
Power Factor: 0.8(Lag)
Rated Voltage: 400/230(V)
Standard Features
1. Engine: VOLVO TD520GE
2. Radiator 50â?? max
3. Fans are driven by belt, with safety guard
4. 24V charge alternator
5. Dry type air filter, fuel filter, oil filter
6. Alternator: single bearing alternator
7. IP23, insulation class H/H
8. Main line circuit breaker
9. Standard control panel
10. Absorber
11. Muffler
12. User manual
PERKINS Diesel Generator Set 75GF
Diesel Generator Set Dat
Set Type: XG-75GF
Standby Output: 75KW/93.75KVA
Prime Output: 68KW/85KVA
Rated Current: 122(A)
Rated Frequency: 50(Hz)
Start-up time: 5ï½?6(s)
Power Factor: 0.8(Lag)
Rated Voltage: 400/230(V)
Standard Features
1. Engine: PERKINS 1104C-44TAG1
2. Radiator 50â?? max
3. Fans are driven by belt, with safety guard
4. 24V charge alternator
5. Dry type air filter, fuel filter, oil filter
6. Alternator: single bearing alternator
7. IP23, insulation class H/H
8. Main line circuit breaker
9. Standard control panel
10. Absorber
11. Muffler
12. User manual
Container Genset
Genset Style
Power Range: 20kw-3000kw
The Container Genset Offer Standard And Silent Types.
The Feature As Below:
1. Design And Manufacture As Per The International Standard Container, I.E.:20 Feet For 1000kva Or Less And 40 Feet For 1250kva Or Above.
2. Available The Csc(international Convention For Safe Containers) Certificate, The Whole Machine Set Can Be Shipped Via Ocean As The Standard Container, And Thence It Can Save Hugely Transport Cost.
3. Two Explosion-proof Lights (an Extra One For The Control Panel) Are Designed Inside The Container, Easy To Operate And Maintain.
4. Available To Access In The Front And At The Back Of The Container, With Two Sides Doors At Both Sides, Easy To Maintain And Repair, With Ladder Outside.
5. All Hinges, Locks And Bolts Are Made Of Stainless Steel, With The Wave And Rain-proof Apparatus Designed Inside.
6. Design The Control Panel And The Output Swichgear At The Same Side Of Container, Easy For User To Make Routine Operation And Connect The Output Cables.
7. With The Permanent Excitation Pmg System Adopted, Which Improves The Start Capacity Of Motor And Resists Against The Wave-based Deformation.
8. Apply Unique Design For Fuel Tank, Pipe, Machine Oil Discharging System And Sound Damper.
9. The Silent Container Is Made By High Performance And Anti-ageing, Flame Retarding, Sound Insulation And Damping Materials, With Unique And Elaborate Design For Air Intake, Outlet And Noise Reduction Device.
Optional Parts: Auto Fuel Feed Pump(or Control Valve), Cooling Liquid Feed Pump, Dual Oil-water Separator, Auto Parallel System And Etc.
Portable Trailer Genset
Genset Style
Product Detail
Portable Trailer Genset Is Installed In Mobile Chassis, It Strong Mobility And Adaptability, Applicable To Rescue Or Emergency Power Construction At Remote Areas.
Trailer Genset
Genset Style
Product Detail
Power Range: 20kw-500kw
Widely Used In Field Operations And Environmental Noise Demanding Places, Or Used As A Backup Power Supply.
Stamford Generator P0 2-POLE
Stamford Genset Supplier
Specifications
50Hz Maximum Continuous (kVA): 20
60Hz Maximum Continuous (kVA): 23
Voltage Designation: Low (< 1000V)
Voltage Range: 220-480
Poles: 2
Prime Movers
Diesel Engine
Applications
Oil & Gas
Prime Power
Combined Heat & Power
Mining
Telecommunications
Auxiliary Power Unit
Critical Protection & UPS
Mobile Construction
Standby
P0 Data Sheets
Additional Specs
AVR: Analogue
Bearing Arrangement: Single
Connection with other machines: Paralleling capability
Excitation System: Self Exciting
Ingress Protection: IP23
Material Insulation Class: H
SAE Adaptors: 2, 3, 4, 5
Technology: Wire Wound
Terminals: 12
Voltage Sensing: 2-Phase
Options
Environmental Protection: Anti-condensation Heaters
Bearing Arrangement: Double
DEUTZ Diesel Generator Set 24GF
Diesel Generator Set Dat
Set Type: XG-24GF
Standby Output: 24KW/30KVA
Prime Output: 22KW/27KVA
Rated Current: 39(A)
Rated Frequency: 50(Hz)
Start-up time: 56(s)
Power Factor: 0.8(Lag)
Rated Voltage: 400/230(V)
Standard Features
1. Engine: DEUTZ D226B-3D
2. Radiator 50 max
3. Fans are driven by belt, with safety guard
4. 24V charge alternator
5. Dry type air filter, fuel filter, oil filter
6. Alternator: single bearing alternator
7. IP23, insulation class H/H
8. Main line circuit breaker
9. Standard control panel
10. Absorber
11. Muffler
12. User manual
WUXI Diesel Generator Set 100GF
Diesel Generator Set Dat
Set Type: XG-100GF
Standby Power: 100KW/125KVA
Prime Power: 91KW/114KVA
Rated Current: 164A
Rated Frequency: 50Hz
Start-up time: 5ï½?6s
Power Factor: 0.8Lag
Rated Voltage: 400/230V
Standard Features
1.Engine:WUXI WD129D11
2.Radiator 50â?? max
3.Fans are driven by belt, with safety guard
4.24V charge alternator
5.Dry type air filter, fuel filter, oil filter
6.Alternator: single bearing alternator
7.IP23, insulation class H/H
8.Main line circuit breaker
9.Standard control panel
10.Absorber
11.Muffler
12.User manual
SHANGCHAI Diesel GeneratorSet 100GF
Diesel Generator Set Dat
Set Type: XG-100GF
Standby Output: 100KW/125KVA
Prime Output: 91KW/114KVA
Rated Current: 164(A)
Rated Frequency: 50Hz
Start-up time: 56s
Power Factor: 0.8Lag
Rated Voltage: 400/230V
Standard Features
1.Engine:Shanghai 6135AD
2.Radiator 50â?? max
3.Fans are driven by belt, with safety guard
4.24V charge alternator
5.Dry type air filter, fuel filter, oil filter
6.Alternator: single bearing alternator
7.IP23, insulation class H/H
8.Main line circuit breaker
9.Standard control panel
10.Absorber
11.muffler
12.User manual