1.PVC crossflow cooling tower fill description:
Marley MX75 is a crossflow film fill, which can provide you cold water in the present splash-fill cooling tower without sacrificing fan horsepower. No other eliminator could come close to MX75 eliminator’s low drift rate and low pressure drop.Now, virtually every eliminator is a nesting cellular PVC type design. Mx75 incorporates highly efficient cellular drift eliminators, which were integrally molded within the fill sheets. Compared with previous designs, these eliminators reduce drift emissions from the tower by a factor of ten or more! Less drift means your saving on your water bills and water treatment chemical expenses. And, you’ll virtually eliminate the nuisance caused by drift spotting on adjacent buildings and property. To save you even more, the drift eliminators discharge air directly toward the fan. Since the air is traveling in the right direction when it leaves the eliminators, you’ll save on fan horsepower.
3.PVC crossflow cooling tower fill technical data:
1. Light weight, high strength, good flame retardant performance, corrosion resistance, advance design, small ventilation resistance, strong hydrophilicity, large contact area, etc.
2. Size/Item: 915* any length, 1220*any length(3 feet*any length)( 4 feet*any length),1520mm*
3. Pitch: 19mm
4. Pitch thickness:0.28-0.38mm
5. Application temperature: 75°C~35°C
6. Application Cooling tower: Cross-flow cooling tower
Cooling Tower Fill is one of the most important components for exchange of gas and water in cooling tower. It is the major parts to improve the efficiency of cooling tower and make sure the economy and safe operation.With the development of the plastic industry, counter-current tower drench water plastic packing shape ladder wave, inclined corrugated fills, which has the heat dissipation, durable, good performance, ventilated small resistance, based on the easy and other advantages.
Counter-flow cooling tower fill with a 19mm pitch. The larger sheet spacing is suitable for water quality slightly less than ideal. RF1900 is used in counter-flow or cross-flow cooling tower applications and is available in glued blocks 305mm wide x 305mm high, and either 1830mm or 2440mm long. RF1900 can also be cut to length to your specific requirements, or supplied as loose sheets.
Cooling towers reject heat from water-cooled systems to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.
1000mm*850mm cooling tower filler specifications:
Width: 850mm
Length: 1000mm
Material: pvc
Sheet space: 16mm
Sheet thickness: 0.28mm-0.38mm
Cooling towers reject heat from water-cooled systems to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.
1220mm cooling tower filler specifications:
Width: 1220mm
Length: meet your request.
Thickness: 0.28mm-0.38mm
Material: pvc
Inclination:5 degree
Sheet space: 20mm
12mm pitch cooling tower filler specification:
Width: 300mm
Length: 1200mm
Material: pvc
Thickness: 0.28mm-0.38mm
Sheet space: 12mm
Description:
Cooling towers reject heat from water-cooled systems to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.
Sloped lamella clarifier is mainly used for sedimentation and sand removal, which is adopted widely in water supply engineering and drainage engineering. Straight-type tube is mainly used as micro-organism carrier for biological filter, high-load biological filter, tower-type biological filter, flooded type biological filter (also called contact oxidation pool) and biological disc-spinning, which can purify industrial organic waste water and urban sewage by bio-chemical treatment.
Sloped tube settler is mainly used for sedimentation and sand removal, which is adopted widely in water supply engineering and drainage engineering. Straight-type tube is mainly used as micro-organism carrier for biological filter, high-load biological filter, tower-type biological filter, flooded type biological filter (also called contact oxidation pool) and biological disc-spinning, which can purify industrial organic waste water and urban sewage by bio-chemical treatment.
Standar sizes:
Width: 1m*1m; Vertical height: 0.866m; Inclined angle: 60degree; Thickness: 0.4-1.5mm
Width: 1.2m*1m; Vertical height: 1m; Inclined angle: 60degree; Thickness: 0.4mm-1.5mm