Please click here to check who's online and chat with them.

Lisun Electronics Co., Ltd.

Supplier From China
Oct-12-15

Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.

Specifications

Product Model SG61000-5SA SG61000-5NA SG61000-5SB SG61000-5NB SG61000-5 SG61000-5H-SP SG61000-5H15-SP SG61000-5T SG61000-5H
Output Voltage (Open) 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20% 1.2/50μs±20%
Output Current (Short) 8/20μs±20% 8/20μs±20% 8/20μs±20% 8/20μs±20% 8/20μs±20% 8/20μs±20% 8/20μs±20% 8/20μs±20% 8/20μs±20%
Output Impedance 2Ω and 12Ω 2Ω and 12Ω 2Ω and 12Ω 2Ω and 12Ω 2Ω and 12Ω 2Ω 12Ω and 500Ω 2Ω 12Ω and 500Ω 2Ω and 12Ω 2Ω 12Ω and 500Ω
Output Voltage Range 0~4.8KV±10% 0~6KV±10% 0~4.8KV±10% 0~6KV±10% 0~6KV±10% 0~10KV±10% 0~15KV±10% 0~6KV±10% 0~10KV±10%
Output Current Range 0~2.4KA±10% 0~3KA±10% 0~2.4KA±10% 0~3KA±10% 0~3KA±10% 0~5KA±10% 0~7.5KA±10% 0~3KA±10% 0~5KA±10%
Surge Repetition 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times
Interval Time 20~9999s 20~9999s 20~9999s 20~9999s 20~9999s 30~9999s 40~9999s 20~9999s 30~9999s
Polarity Positive, Negative or Positive/Negative automatic
Phase Shift Asynchronous, Synchronization 0°~ 360° or Specific Angle
Special Function N/A Built-in surge voltage and current probe (1000:1), connect with LISUN JC2202TA directly
Operation Way Button Input Touch screen with super big LCD and built-in Windows CE
Dimensions (WxDxH) 44x45x35cm 44x45x35cm 44x45x35cm 56x69x155cm 56x69x155cm 44x45x55cm 56x69x155cm
Gross Weight About 30kg About 30kg About 30kg About 270kg About 350kg About 48kg About 270kg
Coupling/Decoupling Network (CDN) Includes a 16A single phase CDN Includes a 20A 3phases CDN
Isolution Transformer for EUT (Option) LISUN ITEU-SP4K (220V Single phase) or ITUS-SP2K (110V) LISUN ITEU-TP10K or ITUS-TP5K
Remark: 12KV, 20KV and more higer voltage Surge Generator can be designed according to customer request.


YWX/Q-010 Standard Salt Spray Corrosion Test Chamber is According to IEC 60068-2-11 Introduction:

YWX/Q-010 Salt Spray Test Equipment is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products.

Model Work Room Size (mm) Exterior Size (mm) Voltage Power (KW)
YWX/Q-150 450X600X400 800x1070x1050 AC220 2.5
YWX/Q-250 600x900x500 870x1400x1150 AC220 3.5
YWX/Q-750 750x1100x500 1030x1680x1260 AC220 4.5
YWX/Q-010 850x1300x600 1160x2000x1390 AC380 6.5
YWX/Q-016 850x1600x600 1280x2320x1500 AC380 9.5
YWX/Q-020 900x2000x600 1220x2530x1410 AC380 11


wooden


Led test system - lpce-2(lms-9000a) spectroradiometer & integrating sphere test system instruction:

Lpce-1 integrating sphere spectrophotometer test system is suitable for photometric and colorimetric measurement of luminaries such as energy-saving lamps, fluorescent lamps, hid lamps (high voltage sodium lamps and high voltage mercury lamps), ccfl and led. The measured data meets the requirements of cie and ies lm-79 for the measurement of photometry and colorimetry.

System configuration:
Quick-scan spectrophotometer colorimeter(lms-5000), optical fiber (cfo-1.2m), digital power meter (ui2008r, option is ui2010), dc power supply (wp3005, option is wp502), ac power source(lsp-500va, option is lsp-1kva or lsp-3kva), integrating sphere (is-1.5m, option is 1.0m or 2.0m size), standard lamp source (sls-50w), 19 inch case

Spectrophotometer integrating sphere system measures photometry, colorimetry and electricity:
• color parameters: chromaticity coordinate, cct (correlated color temperature), cri (color rending index), color difference, peak wavelength;
• photometry parameters: luminous flux, luminous power, luminous flux efficiency;
• electrical parameters: voltage, current, power, power factor



Woden case


LPCE-1 Spectrophotometer & Integrating Sphere System for Test Fluorescent Lamp Introduction:

LPCE-1 Integrating Sphere Spectrophotometer Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.

System Configuration:
Quick-Scan Spectrophotometer Colorimeter(LMS-5000), Optical Fiber (CFO-1.2M), Digital Power Meter (UI2008R, option is UI2010), DC Power Supply (WP3005, option is WP502), AC Power Source(LSP-500VA, option is LSP-1KVA or LSP-3KVA), Integrating Sphere (IS-1.5M, option is 1.0m or 2.0m size), Standard Lamp Source (SLS-50W), 19 Inch Case

LPCE-1 Spectrophotometer & Integrating Sphere UV Test Equipment measures photometry, colorimetry and electricity:
• Color parameters: chromaticity coordinate, CCT (correlated color temperature), CRI (color rending index), color difference, peak wavelength;
• Photometry parameters: luminous flux, luminous power, luminous flux efficiency;
• Electrical parameters: voltage, current, power, power factor
http://www.lisungroup.com/



wooden case


LSG-1800B Lamp LED on-line Goniophotometer for LED Light Measurement Introduction:

LSG-1800B Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B is an update version for LSG-1800, the LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaires.




Be utilized to measure photometric parameters of luminaires for LED road lighting fixture, room lighting fixture and projecting lighting fixture, such as spatial intensity distribution curve, spatial iso-intensity curve, intensity distribution curve on each section (represent by right-angled coordinates or polar coordinates, luminance limitation curve, luminaire efficiency, glare grade, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor and electric parameters voltage, current, wattage, power factor and etc. The measured data meets IES standard format and can be applied for lighting design by lighting design software. The measurement system fully satisfies the requirement of lighting design work.
http://www.lisungroup.com/



wooden case


IEC60529 IP Dust Test Chamber - SC-015 Dustproof Test Instrument Introduction:

The Dust Test Chamber SC-015 is according to IEC60529, GB2423.37-89 (Test L: dust test methods), GB 4208-93 protective casing grade (IP code), GB/T 4942.2-93(protective casing grade of low-voltage apparatus), GB 7000.1-1996, GB 7001-1986(protective casing grade of lamps), DIN40050 and IP5K0. The SC-015 is applied in LED or other luminaries for IP5X and IP6X test

Model Number Working Room Size (mm) Remark
SC-800 800x800x800 Single Door Structure

SC-010 1000x1000x1000
SC-015 1000x1500x1000 Cabinet can be put in a Horizontal direct, or Vertical direct.

SC-020 1000x2000x1000


wooden


LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.



Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR and etc.

Features:
â?¢ The near field detector moved together with the big mirror in a line, the big mirror and far field detector move synchronously.
â?¢ The lumainares will be keep the burning position without moving at all, and the detector will always sense the light directly from the luminares.
â?¢ The rotation motor is from Japan MITSUBISHI MOTORS and it uses Germanic angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop.
â?¢ The working principles are according to IESNA and CIE. The LSG-5000/LSG-3000 are completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996.
â?¢ Special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries.

Specifications:
â?¢ The tested luminaire rotates around the mirror with an angle of (γ) ±180° (or 0-360°) and the tested luminaire rotates around itself with an angle of (C) ±180° (or 0-360°).
â?¢ The accuracy of angle: 0.05°, Resolution of angle: 0.001°
â?¢ Accuracy of photo detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L (LSG-5000)
â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux.
â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10
â?¢ LSG-5000 can be used with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system Goniospectroradiometer (LSG-5000CCD). LSG-5000CCD Goniospectroradiometer=LSG-5000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please refer to the LSG-5000CCD Brochure:

Model No LSG-5000B (Big Size) LSG-5000 (Standard Size) LSG-5000S/LSG-3000B (Small Size)
Measure Non-Flood Lamp Φ 1600*800mm, 50kg Φ 1400*500mm, 40kg Φ 1000*460mm, 30kg
Measure Flood Lamp 600*600mm, 50kg 600*600mm, 40kg 400*400mm, 30kg
Measure Power (W) 600V/10A, AC/DC 600V/10A, AC/DC 600V/10A, AC/DC
PS. The LSG-5000X are special size which According to customers request


LMS-6000 High precision portable spectroradiometer lux meter and chroma color meter for led lighting products measurement

1. Spectral platform: telephoto asymmetrical crossed CT system.

2. Wavelength range: 380~780nm(300~950nm), FWHM: 2nm, Spectral resolution: 0.2nm

3. Sensor: CCD with 3648pix

4. Integration time: 50μs~20000ms

5. Stray light:


 
 
Contact Supplier
Renew

Verification Status