rhythm2, manual etc; the length of wave printing can be adjusted and the function of periodic printing is included to satisfy different applications.
The instrument has the function of regular auto—analysis and auto—interpretation of ecg waveform parameter, provides measurement parameters such as hr, p—r interval, p duration, qrs duration, t duration, q—t interval, q—tc, p , axis, qrs , axis, t axis, r(v5), s(v1), r(v5)+s(v1) etc and auto—interpretation conclusion to help reducing doctor’ s abundance and improve working efficiency.
It has build—in storage with large capacity, and can memory more than 1000 cases, which is easy for the doctor review and statistic.
Support chinese, english, spanish and turkish operating interface, can print out chinese or english report.
Option :ecg—sync software, connect with the pc by usb connector to form a ecg workstation, collect real—time data to the software to analyze and print the report, and can update the old cases in the ecg machine to pc. It has optional functions of fcg, hfecg, qtd, hrv analysis etc.
Injection speed
50(60)ml syringe 0.1ml/h—999.9ml/h (0.1ml/h step)
1000ml/h—1500ml/h (1ml/h step)
30ml syringe 0.1ml/h—900ml/h (0.1ml/h step)
20ml syringe 0.1ml/h—600ml/h (0.1ml/h step)
10mlsyringe 0.1ml/h—300ml/h (0.1ml/h step)
Mechanical accuracy
Within±2%
Bolus rate
50(60)ml syringe: 1200ml/h
30ml syringe: 720ml/h
20ml syringe: 480ml/h
10ml syringe: 240ml/h
Total injection
0.1ml—9999.9ml (0.1ml step)
Alarms
Injection soon finish end of injection occlusion improperly
Installation of syringe wrong setting low battery etc
Kvo speed
1ml/h
Operation environment
A) temperature +5—+40degree
B)humidity 20—90%
C)atmospheric pressure 86.0kpa—106.0kpa
Dimension
280mm(l)x 210mm(w)x 130mm(h)
Syringe
Compatible with any brand
Weight
2.2kg
Package
1pc for each carton, 3.2kg; 35cm (l) × 28cm (w) × 17cm (h)
2pc carton, 6.6kg; 40cm (l) × 39cm (w) × 32cm (h)
3pc carton, 10kg; 59cm (l) × 39cm (w) × 32cm (h)
Infusion rate
1ml/h—1200ml/h (1ml/h step , input 016 when set the rate from 800 to 1200ml/h)
Purge rate
100ml/h—1200ml/h(can be calibrated)
Power source
100v—240v 50/60hz
Internal rechargeable li battery volume≥1, 600mah
4 hours internal battery backup
Alarms
End of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, ac power pulled out etc
Bubble detector
Ultrasonic wave detector, detection sensitivity ≥25μl
Operation environment
Temperature +5—-+40 degree
Relative humidity 20—-90%
Kvo speed
1ml/h—5ml/h (1ml/h step)
Infusion set brand
Compatible with any brand
Dimension
140mm (l)x 157mm (w)x 220mm (h)
Weight
1.8kg
Nibp
Method oscillometry
Modes manual / auto / continuous
Method ra-ll impedance
Range adult: 0-120rpm;pediatric/neonatal: 0-150rpm
Apnea alarm yes
Optional
Etco2, ibp, printer & networking
Ecg
Lead mode 3-iead or 5-lead
Lead selection i, ii, iii, avr, avl, avf, v
Heart rate range
● adult: 15-300bpm
● ped/neo 15-300bpm
Ecg waveform 2 channals
Accuracy ±1 bpm or±1 %, whichever is greater
S-t segment detection: measurement range 0.2mv~2.0mv
Ecg
Lead mode: 5 leads or 3 leads
Lead selection: i, ii, iii, avr, avl, avf, v,
Gain: ´2.5mm/mv, ´5.0mm/mv, ´10mm/mv, ´20mm/mv, auto
Resparation
Method: impedance between r-f(ra-ll)
Bandwidth: 0.3 ~ 2.5 hz
Resolution: 1 rpm
Accuracy : ±2 rpm
Apean alarm: 10 ~ 40 s
Spo2
Measuring range: 0 ~ 100 %
Alarm range: 0 ~ 100 %
Resolution: 1 %
Accuracy
● 70% ~ 100% ±2 %
● 0% ~ 69% unspecified
Actualization interval: about 1 sec.
Alarm delay: 10 sec.
Temperature
Channel: 2
Measuring and alarm range: 0 ~ 50 °c
Resolution: 0.1°c
Accuracy : ±0.1°c
Range
● adult: 15 ~ 300 bpm
● neo/ped: 15 ~ 350 bpm
Accuracy : ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Diagnostic: 0.05 ~ 100 hz
Calibration signal: 1 (mv p-p), accuracy:±5%
St segment monitoring range: measure and alarm -2.0 ~ +2.0 mv
Ecg, nibp, spo2, resp, temp, hr/pr